830 research outputs found
Valutazione di alcune performance diagnostiche di kit ELISA per la diagnosi sierologica di Anemia Infettiva Equina (AIE)
Data on evaluation of some diagnostic parameters of all ELISA kits available in Italy for the serodiagnosis of AIE are presented and discussed. Ten laboratories were involved using a panel of 30 sera ran with 4 commercial kits and 2 in-house kits. Kits were also evaluated using a panel of sera from vaccinated animals at different days post vaccination (p.v.). All sera were also tested in agar gel immunodiffusion (AGID). The parameters evaluated were: diagnostic sensitivity (DSe) and specificity (DSp), Cohen K, weighted Cohen K, coefficient of variation (CV), accordance, concordance. Analysis of these parameters indicates that all kits have a higher sensitivity than AGID, even if a complete evaluation, as indicated by OIE (1) should be carried out
DISTO data on Kpp
The data from the DISTO Collaboration on the exclusive pp -> p K+ Lambda
production acquired at T_p = 2.85 GeV have been re-analysed in order to search
for a deeply bound K- pp (= X) state, to be formed in the binary process pp ->
K+ X. The preliminary spectra of the DeltaM_{K+} missing-mass and of the M_{p
Lambda} invariant-mass show, for large transverse-momenta of protons and kaons,
a distinct broad peak with a mass M_X = 2265 +- 2 MeV/c^2 and a width Gamma_X =
118 +- 8 MeV/c^2.Comment: 8 pages, 4 figures. Talk presented at the "10th International
Conference on Hypernuclear and Strange Particle Physics" (HYP-X), Tokai,
Ibaraki, Japan, September 14th-18th, 2009. To appear in the proceeding
Indication of a deeply bound compact K-pp state formed in the pp -> p Lambda K+ reaction at 2.85 GeV
We have analyzed data of the DISTO experiment on the exclusive pp -> p Lambda
K+ reaction at 2.85 GeV to search for a strongly bound compact K-pp (= X) state
to be formed in the pp -> K+ + X reaction. The observed spectra of the K+
missing-mass and the p Lambda invariant-mass with high transverse momenta of p
and K+ revealed a broad distinct peak with a mass M_X = 2265 +- 2 (stat) +- 5
(syst) MeV/c2 and a width Gamma_X = 118 +- 8 (stat) +- 10 (syst) MeV.Comment: 4 pages, 4 figure
Measurements of the reaction of antiproton annihilation at rest at three hydrogen target densities
The proton-antiproton annihilation at rest into the final state
was measured for three different target densities: liquid hydrogen, gaseous
hydrogen at NTP and at a low pressure of 5 mbar. The yield of this reaction in
the liquid hydrogen target is smaller than in the low-pressure gas target. The
branching ratios of the channel were calculated on the basis of
simultaneous analysis of the three data samples. The branching ratio for
annihilation into from the protonium state turns out to be
about ten times smaller as compared to the one from the state.Comment: 10 pages, 3 Postscript figures. Accepted by Physics Letters
New data on OZI rule violation in bar{p}p annihilation at rest
The results of a measurement of the ratio R = Y(phi pi+ pi-) / Y(omega pi+
pi-) for antiproton annihilation at rest in a gaseous and in a liquid hydrogen
target are presented. It was found that the value of this ratio increases with
the decreasing of the dipion mass, which demonstrates the difference in the phi
and omega production mechanisms. An indication on the momentum transfer
dependence of the apparent OZI rule violation for phi production from the 3S1
initial state was found.Comment: 11 pages, 3 PostScript figures, submitted to Physics Letter
The Fast Read-out System for the MAPMTs of COMPASS RICH-1
A fast readout system for the upgrade of the COMPASS RICH detector has been
developed and successfully used for data taking in 2006 and 2007. The new
readout system for the multi-anode PMTs in the central part of the photon
detector of the RICH is based on the high-sensitivity MAD4
preamplifier-discriminator and the dead-time free F1-TDC chip characterized by
high-resolution. The readout electronics has been designed taking into account
the high photon flux in the central part of the detector and the requirement to
run at high trigger rates of up to 100 kHz with negligible dead-time. The
system is designed as a very compact setup and is mounted directly behind the
multi-anode photomultipliers. The data are digitized on the frontend boards and
transferred via optical links to the readout system. The read-out electronics
system is described in detail together with its measured performances.Comment: Proceeding of RICH2007 Conference, Trieste, Oct. 2007. v2: minor
change
Fast Photon Detection for Particle Identification with COMPASS RICH-1
Particle identification at high rates is an important challenge for many
current and future high-energy physics experiments. The upgrade of the COMPASS
RICH-1 detector requires a new technique for Cherenkov photon detection at
count rates of several per channel in the central detector region, and a
read-out system allowing for trigger rates of up to 100 kHz. To cope with these
requirements, the photon detectors in the central region have been replaced
with the detection system described in this paper. In the peripheral regions,
the existing multi-wire proportional chambers with CsI photocathode are now
read out via a new system employing APV pre-amplifiers and flash ADC chips. The
new detection system consists of multi-anode photomultiplier tubes (MAPMT) and
fast read-out electronics based on the MAD4 discriminator and the F1-TDC chip.
The RICH-1 is in operation in its upgraded version for the 2006 CERN SPS run.
We present the photon detection design, constructive aspects and the first
Cherenkov light in the detector.Comment: Proceedings of the Imaging 2006 conference, Stockholm, Sweden, 27-30
June 2006, 5 pages, 6 figures, to appear in NIM A; corrected typo in caption
of Fig.
- âŠ