830 research outputs found

    Valutazione di alcune performance diagnostiche di kit ELISA per la diagnosi sierologica di Anemia Infettiva Equina (AIE)

    Get PDF
    Data on evaluation of some diagnostic parameters of all ELISA kits available in Italy for the serodiagnosis of AIE are presented and discussed. Ten laboratories were involved using a panel of 30 sera ran with 4 commercial kits and 2 in-house kits. Kits were also evaluated using a panel of sera from vaccinated animals at different days post vaccination (p.v.). All sera were also tested in agar gel immunodiffusion (AGID). The parameters evaluated were: diagnostic sensitivity (DSe) and specificity (DSp), Cohen K, weighted Cohen K, coefficient of variation (CV), accordance, concordance. Analysis of these parameters indicates that all kits have a higher sensitivity than AGID, even if a complete evaluation, as indicated by OIE (1) should be carried out

    DISTO data on Kpp

    Full text link
    The data from the DISTO Collaboration on the exclusive pp -> p K+ Lambda production acquired at T_p = 2.85 GeV have been re-analysed in order to search for a deeply bound K- pp (= X) state, to be formed in the binary process pp -> K+ X. The preliminary spectra of the DeltaM_{K+} missing-mass and of the M_{p Lambda} invariant-mass show, for large transverse-momenta of protons and kaons, a distinct broad peak with a mass M_X = 2265 +- 2 MeV/c^2 and a width Gamma_X = 118 +- 8 MeV/c^2.Comment: 8 pages, 4 figures. Talk presented at the "10th International Conference on Hypernuclear and Strange Particle Physics" (HYP-X), Tokai, Ibaraki, Japan, September 14th-18th, 2009. To appear in the proceeding

    Indication of a deeply bound compact K-pp state formed in the pp -> p Lambda K+ reaction at 2.85 GeV

    Get PDF
    We have analyzed data of the DISTO experiment on the exclusive pp -> p Lambda K+ reaction at 2.85 GeV to search for a strongly bound compact K-pp (= X) state to be formed in the pp -> K+ + X reaction. The observed spectra of the K+ missing-mass and the p Lambda invariant-mass with high transverse momenta of p and K+ revealed a broad distinct peak with a mass M_X = 2265 +- 2 (stat) +- 5 (syst) MeV/c2 and a width Gamma_X = 118 +- 8 (stat) +- 10 (syst) MeV.Comment: 4 pages, 4 figure

    Measurements of the reaction pˉp→ϕη\bar{p}p \to \phi \eta of antiproton annihilation at rest at three hydrogen target densities

    Full text link
    The proton-antiproton annihilation at rest into the ϕη\phi\eta final state was measured for three different target densities: liquid hydrogen, gaseous hydrogen at NTP and at a low pressure of 5 mbar. The yield of this reaction in the liquid hydrogen target is smaller than in the low-pressure gas target. The branching ratios of the ϕη\phi\eta channel were calculated on the basis of simultaneous analysis of the three data samples. The branching ratio for annihilation into ϕη\phi\eta from the 3S1^3S_1 protonium state turns out to be about ten times smaller as compared to the one from the 1P1^1P_1 state.Comment: 10 pages, 3 Postscript figures. Accepted by Physics Letters

    New data on OZI rule violation in bar{p}p annihilation at rest

    Full text link
    The results of a measurement of the ratio R = Y(phi pi+ pi-) / Y(omega pi+ pi-) for antiproton annihilation at rest in a gaseous and in a liquid hydrogen target are presented. It was found that the value of this ratio increases with the decreasing of the dipion mass, which demonstrates the difference in the phi and omega production mechanisms. An indication on the momentum transfer dependence of the apparent OZI rule violation for phi production from the 3S1 initial state was found.Comment: 11 pages, 3 PostScript figures, submitted to Physics Letter

    The Fast Read-out System for the MAPMTs of COMPASS RICH-1

    Full text link
    A fast readout system for the upgrade of the COMPASS RICH detector has been developed and successfully used for data taking in 2006 and 2007. The new readout system for the multi-anode PMTs in the central part of the photon detector of the RICH is based on the high-sensitivity MAD4 preamplifier-discriminator and the dead-time free F1-TDC chip characterized by high-resolution. The readout electronics has been designed taking into account the high photon flux in the central part of the detector and the requirement to run at high trigger rates of up to 100 kHz with negligible dead-time. The system is designed as a very compact setup and is mounted directly behind the multi-anode photomultipliers. The data are digitized on the frontend boards and transferred via optical links to the readout system. The read-out electronics system is described in detail together with its measured performances.Comment: Proceeding of RICH2007 Conference, Trieste, Oct. 2007. v2: minor change

    Fast Photon Detection for Particle Identification with COMPASS RICH-1

    Get PDF
    Particle identification at high rates is an important challenge for many current and future high-energy physics experiments. The upgrade of the COMPASS RICH-1 detector requires a new technique for Cherenkov photon detection at count rates of several 10610^6 per channel in the central detector region, and a read-out system allowing for trigger rates of up to 100 kHz. To cope with these requirements, the photon detectors in the central region have been replaced with the detection system described in this paper. In the peripheral regions, the existing multi-wire proportional chambers with CsI photocathode are now read out via a new system employing APV pre-amplifiers and flash ADC chips. The new detection system consists of multi-anode photomultiplier tubes (MAPMT) and fast read-out electronics based on the MAD4 discriminator and the F1-TDC chip. The RICH-1 is in operation in its upgraded version for the 2006 CERN SPS run. We present the photon detection design, constructive aspects and the first Cherenkov light in the detector.Comment: Proceedings of the Imaging 2006 conference, Stockholm, Sweden, 27-30 June 2006, 5 pages, 6 figures, to appear in NIM A; corrected typo in caption of Fig.
    • 

    corecore