228 research outputs found
Surgical treatment of a rare primary renal carcinoid tumor with liver metastasis
BACKGROUND: Carcinoid tumors are characteristically low grade malignant neoplasms with neuroendocrine differentiation that arise in various body sites, most commonly the lung and gastrointestinal tract, but less frequently the kidneys, breasts, ovaries, testes, prostate and other locations. We report a case of a carcinoid of renal origin with synchronous single liver metastases on radiological studies.
CASE PRESENTATION: A 45 year-old patient who presented with abdominal pain was found on CT scan to have lesions in the right ovary, right kidney, and left hepatic lobe. CA-125, CEA, and CA 19-9 were within normal limits, as were preoperative liver function tests and renal function. Biopsy of the liver mass demonstrated metastatic neuroendocrine tumor. At laparotomy, the patient underwent total abdominal hysterectomy with bilateral salpingo-oophorectomy, radical right nephrectomy with lymphadenectomy, and left hepatectomy. Pathology evaluation reported a right ovarian borderline serous tumor, well-differentiated neuroendocrine carcinoma of the kidney (carcinoid) with 2 positive retroperitoneal lymph nodes, and a single liver metastasis. Immunohistochemistry revealed that this lesion was positive for synaptophysin and CD56, but negative for chromogranin as well as CD10, CD7, and CD20, consistent with a well-differentiated neuroendocrine tumor. She is doing well one year after her initial surgery, with no evidence of tumor recurrence.
CONCLUSION: Early surgical intervention, together with careful surveillance and follow-up, can achieve successful long-term outcomes in patients with this rare malignancy
A comparison of liquid and solid culture for determining relapse and durable cure in phase III TB trials for new regimens
Supported by the Global Alliance for TB Drug Development with support from the Bill & Melinda Gates Foundation, the Medical Research Council (MC_UU_12023/27), the European and Developing Countries Clinical Trials Partnership (grant IP.2007.32011.011), the US Agency for International Development, the UK Department for International Development, the Directorate General for International Cooperation of the Netherlands, Irish Aid, the Australia Department of Foreign Affairs and Trade and National Institutes of Health, AIDS Clinical Trials Group and by grants from the National Institute of Allergy and Infectious Diseases (NIAID) (UM1AI068634, UM1 AI068636 and UM1AI106701) and by NIAID grants to the University of KwaZulu Natal, South Africa, AIDS Clinical Trials Group (ACTG) site 31422 (1U01AI069469); to the Perinatal HIV Research Unit, Chris Hani Baragwanath Hospital, South Africa, ACTG site 12301 (1U01AI069453); and to the Durban International Clinical Trials Unit, South Africa, ACTG site 11201 (1U01AI069426); Bayer Healthcare for the donation of moxifloxacin; and Sanofi for the donation of rifampin. Additional grants were from Chief Scientist Office, Scottish Government, British Society of Antimicrobial Chemotherapy.Background: Tuberculosis kills more people than any other infectious disease, and new regimens are essential. The primary endpoint for confirmatory phase III trials for new regimens is a composite outcome that includes bacteriological treatment failure and relapse. Culture methodology is critical to the primary trial outcome. Patients in clinical trials can have positive cultures after treatment ends that may not necessarily indicate relapse, which was ascribed previously to laboratory cross-contamination or breakdown of old lesions. Löwenstein-Jensen (LJ) medium was the previous standard in clinical trials, but almost all current and future trials will use the Mycobacteria Growth Indicator Tube (MGIT) system due to its simplicity and consistency of use, which will affect phase III trial results. LJ was used for the definition of the primary endpoint in the REMoxTB trial, but every culture was also inoculated in parallel into the MGIT system. The data from this trial, therefore, provide a unique opportunity to investigate and compare the incidence of false ‘isolated positives’ in liquid and solid media and their potential impact on the primary efficacy results. Methods: All post-treatment positive cultures were reviewed in the REMoxTB clinical trial. Logistic regression models were used to model the incidence of isolated positive cultures on MGIT and LJ. Results: A total of 12,209 sputum samples were available from 1652 patients; cultures were more often positive on MGIT than LJ. In 1322 patients with a favourable trial outcome, 126 (9.5%) had cultures that were positive in MGIT compared to 34 (2.6%) patients with positive cultures on LJ. Among patients with a favourable outcome, the incidence of isolated positives on MGIT differed by study laboratory (p < 0.0001) with 21.9% of these coming from one laboratory investigating only 4.9% of patients. No other baseline factors predicted isolated positives on MGIT after adjusting for laboratory. There was evidence of clustering of isolated positive cultures in some patients even after adjusting for laboratory, p < 0.0001. The incidence of isolated positives on MGIT did not differ by treatment arm (p = 0.845, unadjusted). Compared to negative MGIT cultures, positive MGIT cultures were more likely to be associated with higher grade TB symptoms reported within 7 days either side of sputum collection in patients with an unfavourable primary outcome (p < 0.0001) but not in patients with a favourable outcome (p = 0.481). Conclusions: Laboratory cross-contamination was a likely cause of isolated positive MGIT cultures which were clustered in some laboratories. Certain patients had repeated positive MGIT cultures that did not meet the definition of a relapse. This pattern was too common to be explained by cross-contamination only, suggesting that host factors were also responsible. We conclude that MGIT can replace LJ in phase III TB trials, but there are implications for the definition of the primary outcome and patient management in trials in such settings. Most importantly, the methodologies differ in the incidence of isolated positives and in their capacity for capturing non-tuberculosis mycobacteria. It emphasises the importance of effective medical monitoring after treatment ends and consideration of clinical signs and symptoms for determining treatment failure and relapse.Publisher PDFPeer reviewe
Spot sputum samples are at least as good as early morning samples for identifying Mycobacterium tuberculosis
Supported by the Global Alliance for TB Drug Development with support from the Bill and Melinda Gates Foundation, the European and Developing Countries Clinical Trials Partnership (Grant IP.2007.32011.011), US Agency for International Development, UK Department for International Development, Directorate General for International Cooperation of the Netherlands, Irish Aid, Australia Department of Foreign Affairs and Trade, National Institutes of Health, AIDS Clinical Trials Group. The study was also supported by grants from the National Institute of Allergy and Infectious Diseases (NIAID) (UM1AI068634, UM1 AI068636, and UM1AI106701) and by NIAID grants to the University of KwaZulu Natal, South Africa, AIDS Clinical Trials Group (ACTG) site 31422 (1U01AI069469); to the Perinatal HIV Research Unit, Chris Hani Baragwanath Hospital, South Africa, ACTG site 12301 (1U01AI069453); and to the Durban International Clinical Trials Unit, South Africa, ACTG site 11201 (1U01AI069426). Bayer Healthcare for donated moxifloxacin and Sanofi donated rifampin.Background: The use of early morning sputum samples (EMS) to diagnose tuberculosis (TB) can result in treatment delay given the need for the patient to return to the clinic with the EMS, increasing the chance of patients being lost during their diagnostic workup. However, there is little evidence to support the superiority of EMS over spot sputum samples. In this new analysis of the REMoxTB study, we compare the diagnostic accuracy of EMS with spot samples for identifying Mycobacterium tuberculosis pre- and post-treatment. Methods: Patients who were smear positive at screening were enrolled into the study. Paired sputum samples (one EMS and one spot) were collected at each trial visit pre- and post-treatment. Microscopy and culture on solid LJ and liquid MGIT media were performed on all samples; those missing corresponding paired results were excluded from the analyses. Results: Data from 1115 pre- and 2995 post-treatment paired samples from 1931 patients enrolled in the REMoxTB study were analysed. Patients were recruited from South Africa (47%), East Africa (21%), India (20%), Asia (11%), and North America (1%); 70% were male, median age 31 years (IQR 24–41), 139 (7%) co-infected with HIV with a median CD4 cell count of 399 cells/μL (IQR 318–535). Pre-treatment spot samples had a higher yield of positive Ziehl–Neelsen smears (98% vs. 97%, P = 0.02) and LJ cultures (87% vs. 82%, P = 0.006) than EMS, but there was no difference for positivity by MGIT (93% vs. 95%, P = 0.18). Contaminated and false-positive MGIT were found more often with EMS rather than spot samples. Surprisingly, pre-treatment EMS had a higher smear grading and shorter time-to-positivity, by 1 day, than spot samples in MGIT culture (4.5 vs. 5.5 days, P < 0.001). There were no differences in time to positivity in pre-treatment LJ culture, or in post-treatment MGIT or LJ cultures. Comparing EMS and spot samples in those with unfavourable outcomes, there were no differences in smear or culture results, and positive results were not detected earlier in Kaplan–Meier analyses in either EMS or spot samples. Conclusions: Our data do not support the hypothesis that EMS samples are superior to spot sputum samples in a clinical trial of patients with smear positive pulmonary TB. Observed small differences in mycobacterial burden are of uncertain significance and EMS samples do not detect post-treatment positives any sooner than spot samples.Publisher PDFPeer reviewe
Topological Defects and CMB anisotropies : Are the predictions reliable ?
We consider a network of topological defects which can partly decay into
neutrinos, photons, baryons, or Cold Dark Matter. We find that the degree-scale
amplitude of the cosmic microwave background (CMB) anisotropies as well as the
shape of the matter power spectrum can be considerably modified when such a
decay is taken into account. We conclude that present predictions concerning
structure formation by defects might be unreliable.Comment: 14 pages, accepted for publication in PR
The myositis clinical phenotype associated with anti-Zo autoantibodies: a case series of nine UK patients
Upper limits on the strength of periodic gravitational waves from PSR J1939+2134
The first science run of the LIGO and GEO gravitational wave detectors
presented the opportunity to test methods of searching for gravitational waves
from known pulsars. Here we present new direct upper limits on the strength of
waves from the pulsar PSR J1939+2134 using two independent analysis methods,
one in the frequency domain using frequentist statistics and one in the time
domain using Bayesian inference. Both methods show that the strain amplitude at
Earth from this pulsar is less than a few times .Comment: 7 pages, 1 figure, to appear in the Proceedings of the 5th Edoardo
Amaldi Conference on Gravitational Waves, Tirrenia, Pisa, Italy, 6-11 July
200
Improving the sensitivity to gravitational-wave sources by modifying the input-output optics of advanced interferometers
We study frequency dependent (FD) input-output schemes for signal-recycling
interferometers, the baseline design of Advanced LIGO and the current
configuration of GEO 600. Complementary to a recent proposal by Harms et al. to
use FD input squeezing and ordinary homodyne detection, we explore a scheme
which uses ordinary squeezed vacuum, but FD readout. Both schemes, which are
sub-optimal among all possible input-output schemes, provide a global noise
suppression by the power squeeze factor, while being realizable by using
detuned Fabry-Perot cavities as input/output filters. At high frequencies, the
two schemes are shown to be equivalent, while at low frequencies our scheme
gives better performance than that of Harms et al., and is nearly fully
optimal. We then study the sensitivity improvement achievable by these schemes
in Advanced LIGO era (with 30-m filter cavities and current estimates of
filter-mirror losses and thermal noise), for neutron star binary inspirals, and
for narrowband GW sources such as low-mass X-ray binaries and known radio
pulsars. Optical losses are shown to be a major obstacle for the actual
implementation of these techniques in Advanced LIGO. On time scales of
third-generation interferometers, like EURO/LIGO-III (~2012), with
kilometer-scale filter cavities, a signal-recycling interferometer with the FD
readout scheme explored in this paper can have performances comparable to
existing proposals. [abridged]Comment: Figs. 9 and 12 corrected; Appendix added for narrowband data analysi
Quantum state preparation and macroscopic entanglement in gravitational-wave detectors
Long-baseline laser-interferometer gravitational-wave detectors are operating
at a factor of 10 (in amplitude) above the standard quantum limit (SQL) within
a broad frequency band. Such a low classical noise budget has already allowed
the creation of a controlled 2.7 kg macroscopic oscillator with an effective
eigenfrequency of 150 Hz and an occupation number of 200. This result, along
with the prospect for further improvements, heralds the new possibility of
experimentally probing macroscopic quantum mechanics (MQM) - quantum mechanical
behavior of objects in the realm of everyday experience - using
gravitational-wave detectors. In this paper, we provide the mathematical
foundation for the first step of a MQM experiment: the preparation of a
macroscopic test mass into a nearly minimum-Heisenberg-limited Gaussian quantum
state, which is possible if the interferometer's classical noise beats the SQL
in a broad frequency band. Our formalism, based on Wiener filtering, allows a
straightforward conversion from the classical noise budget of a laser
interferometer, in terms of noise spectra, into the strategy for quantum state
preparation, and the quality of the prepared state. Using this formalism, we
consider how Gaussian entanglement can be built among two macroscopic test
masses, and the performance of the planned Advanced LIGO interferometers in
quantum-state preparation
Search for gravitational wave bursts in LIGO's third science run
We report on a search for gravitational wave bursts in data from the three
LIGO interferometric detectors during their third science run. The search
targets subsecond bursts in the frequency range 100-1100 Hz for which no
waveform model is assumed, and has a sensitivity in terms of the
root-sum-square (rss) strain amplitude of hrss ~ 10^{-20} / sqrt(Hz). No
gravitational wave signals were detected in the 8 days of analyzed data.Comment: 12 pages, 6 figures. Amaldi-6 conference proceedings to be published
in Classical and Quantum Gravit
- …