43 research outputs found

    Magnetic anomalies in single crystalline Tb5Si3

    Full text link
    The polycrystalline form of the compound, Tb5Si3, crystallizing in Mn5Si3-type hexagonal structure, which was earlier believe to order antiferromagnetically below 69 K, has been recently reported by us to exhibit interesting magnetoresistance (MR) anomalies. In order to understand the magnetic anomalies of this compound better, we synthesized single crystals of this compound and subjected them to intense magnetization and MR studies. The results reveal that the magnetic behavior is strongly anisotropic as the easy axis is along a basal plane. There appear to be multiple magnetic features in the close vicinity of 70 K. In addition, there are multiple steps in isothermal magnetization (which could not be resolved in the data for polycrystalline data) for magnetic-field (H) along a basal plane. The sign of MR is positive in the magnetically ordered state, and, interestingly, the magnitude dramatically increases at the initial step for H parallel to basal plane, but decreases at subsequent steps as though the origin of these steps are different. However, for the perpendicular orientation (H || [0 0 0 1]), there is no evidence for any step either in M(H) or in MR(H). These results establish this compound is an interesting magnetic material

    The Physics of the B Factories

    Get PDF

    Micromotion at the Tibial Plateau in Primary and Revision Total Knee Arthroplasty: Fixed Versus Rotating Platform Designs

    No full text
    OBJECTIVES: Initial stability of tibial trays is crucial for long-term success of total knee arthroplasty (TKA) in both primary and revision settings. Rotating platform (RP) designs reduce torque transfer at the tibiofemoral interface. We asked if this reduced torque transfer in RP designs resulted in subsequently reduced micromotion at the cemented fixation interface between the prosthesis component and the adjacent bone. METHODS: Composite tibias were implanted with fixed and RP primary and revision tibial trays and biomechanically tested under up to 2.5 kN of axial compression and 10° of external femoral component rotation. Relative micromotion between the implanted tibial tray and the neighbouring bone was quantified using high-precision digital image correlation techniques. RESULTS: Rotational malalignment between femoral and tibial components generated 40% less overall tibial tray micromotion in RP designs than in standard fixed bearing tibial trays. RP trays reduced micromotion by up to 172 µm in axial compression and 84 µm in rotational malalignment models. CONCLUSIONS: Reduced torque transfer at the tibiofemoral interface in RP tibial trays reduces relative component micromotion and may aid long-term stability in cases of revision TKA or poor bone quality. Cite this article: Mr S. R. Small. Micromotion at the tibial plateau in primary and revision total knee arthroplasty: fixed versus rotating platform designs. Bone Joint Res 2016;5:122–129. DOI: 10.1302/2046-3758.54.2000481
    corecore