23 research outputs found

    Lubricated revolute joints in rigid multibody systems

    Get PDF
    The main purpose of this work is to present a general methodology for modeling lubricated revolute joints in constrained rigid multibody systems. In the dynamic analysis of journal-bearings, the hydrodynamic forces, which include both squeeze and wedge effects, generated by the lubricant fluid, oppose the journal motion. The hydrodynamic forces are obtained by integrating the pressure distribution evaluated with the aid of Reynolds’ equation, written for the dynamic regime. The hydrodynamic forces built up by the lubricant fluid are evaluated from the system state variables and included into the equations of motion of the multibody system. Numerical examples are presented in order to demonstrate the use of the methodologies and procedures described in this work.Fundação para a Ciência e a Tecnologia (FCT

    Mortality from esophagectomy for esophageal cancer across low, middle, and high-income countries: An international cohort study.

    No full text
    BACKGROUND No evidence currently exists characterising global outcomes following major cancer surgery, including esophageal cancer. Therefore, this study aimed to characterise impact of high income countries (HIC) versus low and middle income countries (LMIC) on the outcomes following esophagectomy for esophageal cancer. METHOD This international multi-center prospective study across 137 hospitals in 41 countries included patients who underwent an esophagectomy for esophageal cancer, with 90-day follow-up. The main explanatory variable was country income, defined according to the World Bank Data classification. The primary outcome was 90-day postoperative mortality, and secondary outcomes were composite leaks (anastomotic leak or conduit necrosis) and major complications (Clavien-Dindo Grade III - V). Multivariable generalized estimating equation models were used to produce adjusted odds ratios (ORs) and 95% confidence intervals (CI). RESULTS Between April 2018 to December 2018, 2247 patients were included. Patients from HIC were more significantly older, with higher ASA grade, and more advanced tumors. Patients from LMIC had almost three-fold increase in 90-day mortality, compared to HIC (9.4% vs 3.7%, p < 0.001). On adjusted analysis, LMIC were independently associated with higher 90-day mortality (OR: 2.31, CI: 1.17-4.55, p = 0.015). However, LMIC were not independently associated with higher rates of anastomotic leaks (OR: 1.06, CI: 0.57-1.99, p = 0.9) or major complications (OR: 0.85, CI: 0.54-1.32, p = 0.5), compared to HIC. CONCLUSION Resections in LMIC were independently associated with higher 90-day postoperative mortality, likely reflecting a failure to rescue of these patients following esophagectomy, despite similar composite anastomotic leaks and major complication rates to HIC. These findings warrant further research, to identify potential issues and solutions to improve global outcomes following esophagectomy for cancer

    Beam Test Performance Studies of CMS Phase-2 Outer Tracker Module Prototypes

    No full text
    International audienceA new tracking detector will be installed as part of the Phase-2 upgrade of the CMS detector for the high-luminosity LHC era. This tracking detector includes the Inner Tracker, equipped with silicon pixel sensor modules, and the Outer Tracker, consisting of modules with two parallel stacked silicon sensors. The Outer Tracker front-end ASICs will be able to correlate hits from charged particles in these two sensors to perform on-module discrimination of transverse momenta pTp_\mathrm{T}. The pTp_\mathrm{T} information is generated at a frequency of 40 MHz and will be used in the Level-1 trigger decision of CMS. Prototypes of the so-called 2S modules were tested at the Test Beam Facility at DESY Hamburg between 2019 and 2020. These modules use the final front-end ASIC, the CMS Binary Chip (CBC), and for the first time the Concentrator Integrated Circuit (CIC), optical readout and on-module power conversion. In total, seven modules were tested, one of which was assembled with sensors irradiated with protons. An important aspect was to show that it is possible to read out modules synchronously. A cluster hit efficiency of about 99.75% was achieved for all modules. The CBC pTp_\mathrm{T} discrimination mechanism has been verified to work together with the CIC and optical readout. The measured module performance meets the requirements for operation in the upgraded CMS tracking detector
    corecore