4,098 research outputs found

    Fascicles and the interfascicular matrix show adaptation for fatigue resistance in energy storing tendons

    Get PDF
    Tendon is composed of rope-like fascicles, bound together by interfascicular matrix (IFM). Our previous work shows that the IFM is critical for tendon function, facilitating sliding between fascicles to allow tendons to stretch. This function is particularly important in energy storing tendons, which experience extremely high strains during exercise, and therefore require the capacity for considerable inter-fascicular sliding and recoil. This capacity is not required in positional tendons. Whilst we have previously described the quasi-static properties of the IFM, the fatigue resistance of the IFM in functionally distinct tendons remains unknown. We therefore tested the hypothesis that fascicles and IFM in the energy storing equine superficial digital flexor tendon (SDFT) are more fatigue resistant than those in the positional common digital extensor tendon (CDET). Fascicles and IFM from both tendon types were subjected to cyclic fatigue testing until failure, and mechanical properties were calculated. The results demonstrated that both fascicles and IFM from the energy storing SDFT were able to resist a greater number of cycles before failure than those from the positional CDET. Further, SDFT fascicles and IFM exhibited less hysteresis over the course of testing than their counterparts in the CDET. This is the first study to assess the fatigue resistance of the IFM, demonstrating that IFM has a functional role within tendon and contributes significantly to tendon mechanical properties. These data provide important advances into fully characterising tendon structure-function relationships

    Effect of fatigue loading on structure and functional behaviour of fascicles from energy-storing tendons

    Get PDF
    Tendons can broadly be categorized according to their function: those that act purely to position the limb and those that have an additional function as energy stores. Energy-storing tendons undergo many cycles of large deformations during locomotion, and so must be able to extend and recoil efficiently, rapidly and repeatedly. Our previous work has shown rotation in response to applied strain in fascicles from energy-storing tendons, indicating the presence of helical substructures which may provide greater elasticity and recovery. In the current study, we assessed how preconditioning and fatigue loading affect the ability of fascicles from the energy-storing equine superficial digital flexor tendon to extend and recoil. We hypothesized that preconditioned samples would exhibit changes in microstructural strain response, but would retain their ability to recover. We further hypothesized that fatigue loading would result in sample damage, causing further alterations in extension mechanisms and a significant reduction in sample recovery. The results broadly support these hypotheses: preconditioned samples showed some alterations in microstructural strain response, but were able to recover following the removal of load. However, fatigue loaded samples showed visual evidence of damage and exhibited further alterations in extension mechanisms, characterized by decreased rotation in response to applied strain. This was accompanied by increased hysteresis and decreased recovery. These results suggest that fatigue loading results in a compromised helix substructure, reducing the ability of energy-storing tendons to recoil. A decreased ability to recoil may lead to an impaired response to further loading, potentially increasing the likelihood of injury

    Fast oxidation of sulfur dioxide by hydrogen peroxide in deliquesced aerosol particles

    Get PDF
    Atmospheric sulfate aerosols have important impacts on air quality, climate, and human and ecosystem health. However, current air-quality models generally underestimate the rate of conversion of sulfur dioxide (SO2) to sulfate during severe haze pollution events, indicating that our understanding of sulfate formation chemistry is incomplete. This may arise because the air-quality models rely upon kinetics studies of SO2 oxidation conducted in dilute aqueous solutions, and not at the high solute strengths of atmospheric aerosol particles. Here, we utilize an aerosol flow reactor to perform direct investigation on the kinetics of aqueous oxidation of dissolved SO2 by hydrogen peroxide (H2O2) using pH-buffered, submicrometer, deliquesced aerosol particles at relative humidity of 73 to 90%. We find that the high solute strength of the aerosol particles significantly enhances the sulfate formation rate for the H2O2 oxidation pathway compared to the dilute solution. By taking these effects into account, our results indicate that the oxidation of SO2 by H2O2 in the liquid water present in atmospheric aerosol particles can contribute to the missing sulfate source during severe haze episodes

    Accurate Measurements of Aerosol Hygroscopic Growth over a Wide Range in Relative Humidity

    Get PDF
    Using a comparative evaporation kinetics approach, we describe a new and accurate method for determining the equilibrium hygroscopic growth of aerosol droplets. The time-evolving size of an aqueous droplet, as it evaporates to a steady size and composition that is in equilibrium with the gas phase relative humidity, is used to determine the time-dependent mass flux of water, yielding information on the vapor pressure of water above the droplet surface at every instant in time. Accurate characterization of the gas phase relative humidity is provided from a control measurement of the evaporation profile of a droplet of know equilibrium properties, either a pure water droplet or a sodium chloride droplet. In combination, and by comparison with simulations that account for both the heat and mass transport governing the droplet evaporation kinetics, these measurements allow accurate retrieval of the equilibrium properties of the solution droplet (i.e., the variations with water activity in the mass fraction of solute, diameter growth factor, osmotic coefficient or number of water molecules per solute molecule). Hygroscopicity measurements can be made over a wide range in water activity (from >0.99 to, in principle, 0.9 and ∼±1% below 80% RH, and maximum uncertainties in diameter growth factor of ±0.7%. For all of the inorganic systems examined, the time-dependent data are consistent with large values of the mass accommodation (or evaporation) coefficient (>0.1)

    FLICK: developing and running application-specific network services

    Get PDF
    Data centre networks are increasingly programmable, with application-specific network services proliferating, from custom load-balancers to middleboxes providing caching and aggregation. Developers must currently implement these services using traditional low-level APIs, which neither support natural operations on application data nor provide efficient performance isolation. We describe FLICK, a framework for the programming and execution of application-specific network services on multi-core CPUs. Developers write network services in the FLICK language, which offers high-level processing constructs and application-relevant data types. FLICK programs are translated automatically to efficient, parallel task graphs, implemented in C++ on top of a user-space TCP stack. Task graphs have bounded resource usage at runtime, which means that the graphs of multiple services can execute concurrently without interference using cooperative scheduling. We evaluate FLICK with several services (an HTTP load-balancer, a Memcached router and a Hadoop data aggregator), showing that it achieves good performance while reducing development effort

    Hygroscopic properties of aminium sulfate aerosols

    Get PDF
    Alkylaminium sulfates originate from the neutralisation reaction between short-chained amines and sulfuric acid and have been detected in atmospheric aerosol particles. Their physicochemical behaviour is less well characterised than their inorganic equivalent, ammonium sulfate, even though they play a role in atmospheric processes such as the nucleation and growth of new particles and cloud droplet formation. In this work, a comparative evaporation kinetics experimental technique using a cylindrical electrodynamic balance is applied to determine the hygroscopic properties of six short-chained alkylaminium sulfates, specifically mono-, di-, and tri-methylaminium sulfate and mono-, di-, and tri-ethyl aminium sulfate. This approach allows for the retrieval of a water-activity-dependent growth curve in less than 10 s, avoiding the uncertainties that can arise from the volatilisation of semi-volatile components. Measurements are made on particles > 5 µm in radius, avoiding the need to correct equilibrium measurements for droplet-surface curvature with assumed values of the droplet-surface tension. Variations in equilibrium solution droplet composition with varying water activity are reported over the range 0.5 to > 0.98, along with accurate parameterisations of solution density and refractive index. The uncertainties in water activities associated with the hygroscopicity measurements are typically  0.9 and  ∼  ±1 % below 0.9, with maximum uncertainties in diameter growth factors of ±0.7 %. Comparison with previously reported measurements show deviation across the entire water activity range

    Hygroscopic properties of aminium sulfate aerosols

    Get PDF
    Alkylaminium sulfates originate from the neutralisation reaction between short-chained amines and sulfuric acid and have been detected in atmospheric aerosol particles. Their physicochemical behaviour is less well characterised than their inorganic equivalent, ammonium sulfate, even though they play a role in atmospheric processes such as the nucleation and growth of new particles and cloud droplet formation. In this work, a comparative evaporation kinetics experimental technique using a cylindrical electrodynamic balance is applied to determine the hygroscopic properties of six short-chained alkylaminium sulfates, specifically mono-, di-, and tri-methylaminium sulfate and mono-, di-, and tri-ethyl aminium sulfate. This approach allows for the retrieval of a water-activity-dependent growth curve in less than 10 s, avoiding the uncertainties that can arise from the volatilisation of semi-volatile components. Measurements are made on particles > 5 µm in radius, avoiding the need to correct equilibrium measurements for droplet-surface curvature with assumed values of the droplet-surface tension. Variations in equilibrium solution droplet composition with varying water activity are reported over the range 0.5 to > 0.98, along with accurate parameterisations of solution density and refractive index. The uncertainties in water activities associated with the hygroscopicity measurements are typically  0.9 and  ∼  ±1 % below 0.9, with maximum uncertainties in diameter growth factors of ±0.7 %. Comparison with previously reported measurements show deviation across the entire water activity range
    corecore