1,058 research outputs found

    A new wireless underground network system for continuous monitoring of soil water contents

    Get PDF
    A new stand-alone wireless embedded network system has been developed recently for continuous monitoring of soil water contents at multiple depths. This paper presents information on the technical aspects of the system, including the applied sensor technology, the wireless communication protocols, the gateway station for data collection, and data transfer to an end user Web page for disseminating results to targeted audiences. Results from the first test of the network system are presented and discussed, including lessons learned so far and actions to be undertaken in the near future to improve and enhance the operability of this innovative measurement approac

    TCR V α- and V ß-Gene Segment Use in T-Cell Subcultures Derived from a Type-III Bare Lymphocyte Syndrome Patient Deficient in MHC Class-II Expression

    Get PDF
    Previously, we and others have shown that MHC class-II deficient humans have greatly reduced numbers of CD4+CD8– peripheral T cells. These type-III Bare Lymphocyte Syndrome patients lack MHC class-II and have an impaired MHC class-I antigen expression. In this study, we analyzed the impact of the MHC class-II deficient environment on the TCR V-gene segment usage in this reduced CD4+CD8– T-cell subset. For these studies, we employed TcR V-region-specific monoclonal antibodies (mAbs) and a semiquantitative PCR technique with V α and V ß amplimers, specific for each of the most known V α- and V ß;-gene region families. The results of our studies demonstrate that some of the V α-gene segments are used less frequent in the CD4+CD8– T-cell subset of the patient, whereas the majority of the TCR V α- and V ß-gene segments investigated were used with similar frequencies in both subsets in the type-III Bare Lymphocyte Syndrome patient compared to healthy control family members. Interestingly, the frequency of TcR V α12 transcripts was greatly diminished in the patient, both in the CD4+CD8– as well as in the CD4–CD8+ compartment, whereas this gene segment could easily be detected in the healthy family controls. On the basis of the results obtained in this study, it is concluded that within the reduced CD4+CD8– T-cell subset of this patient, most of the TCR V-gene segments tested for are employed. However, a skewing in the usage frequency of some of the V α-gene segments toward the CD4–CD8+ T-cell subset was noticeable in the MHC class-II deficient patient that differed from those observed in the healthy family controls

    Molecular detection of

    Get PDF

    Three-year randomised clinical trial to evaluate the clinical performance, quantitative and qualitative wear patterns of hybrid composite restorations

    Get PDF
    The aim of the study was to compare the clinical performance, quantitative and qualitative wear patterns of conventional hybrid (Tetric Ceram), micro-filled hybrid (Gradia Direct Posterior) and nano-hybrid (Tetric EvoCeram, TEC) posterior composite restorations in a 3-year randomised clinical trial. Sixteen Tetric Ceram, 17 TEC and 16 Gradia Direct Posterior restorations were placed in human molars and evaluated at baseline, 6, 12, 24 and 36 months of clinical service according to US Public Health Service criteria. The gypsum replicas at each recall were used for 3D laser scanning to quantify wear, and the epoxy resin replicas were observed under scanning electron microscope to study the qualitative wear patterns. After 3 years of clinical service, the three hybrid restorative materials performed clinically well in posterior cavities. Within the observation period, the nano-hybrid and micro-hybrid restorations evolved better in polishability with improved surface gloss retention than the conventional hybrid counterpart. The three hybrid composites showed enamel-like vertical wear and cavity-size dependant volume loss magnitude. Qualitatively, while the micro-filled and nano-hybrid composite restorations exhibited signs of fatigue similar to the conventional hybrid composite restorations at heavy occlusal contact area, their light occlusal contact areas showed less surface pitting after 3 years of clinical service

    Benchmarked performance charts using principal components analysis to improve the effectiveness of feedback for audit data in HIV care

    Get PDF
    Abstract Background Feedback tools for clinical audit data that compare site-specific results to average performance over all sites can be useful for quality improvement. Proposed tools should be simple and clearly benchmark the site’s performance, so that a relevant action plan can be directly implemented to improve patient care services. We aimed to develop such a tool in order to feedback data to UK HIV clinics participating in the 2015 British HIV Association (BHIVA) audit assessing compliance with the 2011 guidelines for routine investigation and monitoring of adult HIV-1- infected individuals. Methods HIV clinic sites were asked to provide data on a random sample of 50–100 adult patients attending for HIV care during 2014 and/or 2015 by completing a self-audit spreadsheet. Outcomes audited included the proportion of patients with recorded resistance testing, viral load monitoring, adherence assessment, medications, hepatitis testing, vaccination management, risk assessments, and sexual health screening. For each outcome we benchmarked the proportion for a specific site against the average performance. We produced performance charts for each site using boxplots for the outcomes. We also used the mean and differences from the mean performance to produce a dashboard for each site. We used principal components analysis to group correlated outcomes and simplify the dashboard. Results The 106 sites included in the study provided information on a total of 7768 patients. Outcomes capturing monitoring of treatment of HIV-infection showed high performance across the sites, whereas testing for hepatitis, and risk assessment for cardiovascular disease and smoking, management of flu vaccination, sexual health screening, and cervical cytology for women were very variable across sites. The principal components analysis reduced the original 12 outcomes to four factors that represented HIV care, hepatitis testing, other screening tests, and resistance testing. These provided simplified measures of adherence to guidelines which were presented as a 4 bar dashboard of performance. Conclusion Our dashboard performance charts provide easily digestible visual summaries of locally relevant audit data that are benchmarked against the overall mean and can be used to improve feedback to HIV services. Feedback from clinicians indicated that they found these charts acceptable and useful
    • …
    corecore