613 research outputs found

    Fast Photon Detection for Particle Identification with COMPASS RICH-1

    Get PDF
    Particle identification at high rates is an important challenge for many current and future high-energy physics experiments. The upgrade of the COMPASS RICH-1 detector requires a new technique for Cherenkov photon detection at count rates of several 10610^6 per channel in the central detector region, and a read-out system allowing for trigger rates of up to 100 kHz. To cope with these requirements, the photon detectors in the central region have been replaced with the detection system described in this paper. In the peripheral regions, the existing multi-wire proportional chambers with CsI photocathode are now read out via a new system employing APV pre-amplifiers and flash ADC chips. The new detection system consists of multi-anode photomultiplier tubes (MAPMT) and fast read-out electronics based on the MAD4 discriminator and the F1-TDC chip. The RICH-1 is in operation in its upgraded version for the 2006 CERN SPS run. We present the photon detection design, constructive aspects and the first Cherenkov light in the detector.Comment: Proceedings of the Imaging 2006 conference, Stockholm, Sweden, 27-30 June 2006, 5 pages, 6 figures, to appear in NIM A; corrected typo in caption of Fig.

    Fast photon detection for the COMPASS RICH detector

    Get PDF
    The COMPASS experiment at the SPS accelerator at CERN uses a large scale Ring Imaging CHerenkov detector (RICH) to identify pions, kaons and protons in a wide momentum range. For the data taking in 2006, the COMPASS RICH has been upgraded in the central photon detection area (25% of the surface) with a new technology to detect Cherenkov photons at very high count rates of several 10^6 per second and channel and a new dead-time free read-out system, which allows trigger rates up to 100 kHz. The Cherenkov photons are detected by an array of 576 visible and ultra-violet sensitive multi-anode photomultipliers with 16 channels each. The upgraded detector showed an excellent performance during the 2006 data taking.Comment: Proceeding of the IPRD06 conference (Siena, Okt. 06

    The Fast Read-out System for the MAPMTs of COMPASS RICH-1

    Full text link
    A fast readout system for the upgrade of the COMPASS RICH detector has been developed and successfully used for data taking in 2006 and 2007. The new readout system for the multi-anode PMTs in the central part of the photon detector of the RICH is based on the high-sensitivity MAD4 preamplifier-discriminator and the dead-time free F1-TDC chip characterized by high-resolution. The readout electronics has been designed taking into account the high photon flux in the central part of the detector and the requirement to run at high trigger rates of up to 100 kHz with negligible dead-time. The system is designed as a very compact setup and is mounted directly behind the multi-anode photomultipliers. The data are digitized on the frontend boards and transferred via optical links to the readout system. The read-out electronics system is described in detail together with its measured performances.Comment: Proceeding of RICH2007 Conference, Trieste, Oct. 2007. v2: minor change

    Airborne measurements of carbonaceous aerosol soluble in water over northeastern United States: Method development and an investigation into water-soluble organic carbon sources

    Get PDF
    [1] A particle-into-liquid sampler (PILS) was coupled to a total organic carbon (TOC) analyzer for 3 s integrated measurements of water-soluble organic carbon (WSOC) in PM 1 ambient particles. The components of the instrument are described in detail. The PILS-TOC was deployed on the NOAA WP-3D aircraft during the NEAQS/ITCT 2004 program to investigate WSOC sources over the northeastern United States and Canada. Two main sources were identified: biomass burning emissions from fires in Alaska and northwestern Canada and emissions emanating from urban centers. Biomass burning WSOC was correlated with carbon monoxide (CO) and acetonitrile (r 2 > 0.88). These plumes were intercepted in layers at altitudes between 3 and 4 km and contained the highest fine particle volume and WSOC concentrations of the mission. Apart from the biomass burning influence, the lowest WSOC concentrations were recorded in rural air masses that included regions of significant biogenic emissions. Highest concentrations were at low altitudes in distinct plumes from urban centers. WSOC and CO were highly correlated (r 2 > 0.78) in these urban plumes. The ratio of the enhancement in WSOC relative to CO enhancement was found to be low (3mgC/m3/ppmv)inplumesthathadbeenintransitforashorttime,andincreasedwithplumeage,butappearedtoleveloffat3 mg C/m 3 /ppmv) in plumes that had been in transit for a short time, and increased with plume age, but appeared to level off at 32 ± 4 mg C/m 3 /ppmv after 1dayoftransportfromthesources.TheresultssuggestthattheproductionofWSOCinfineparticlesdependsoncompoundscoemittedwithCOandthatthisprocessisrapidwithatimeconstantof1 day of transport from the sources. The results suggest that the production of WSOC in fine particles depends on compounds coemitted with CO and that this process is rapid with a time constant of 1 day. Citation: Sullivan, A. P., R. E. Peltier, C. A. Brock, J. A. de Gouw, J. S. Holloway, C. Warneke, A. G. Wollny, and R. J. Weber (2006), Airborne measurements of carbonaceous aerosol soluble in water over northeastern United States: Method development and an investigation into water-soluble organic carbon sources

    Reducing unnecessary prescriptions of antibiotics for acute cough: Adaptation of a leaflet aimed at Turkish immigrants in Germany

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>The reduction in the number of unnecessary prescriptions of antibiotics has become one of the most important objectives for primary health care. German GPs report that they are under "pressure to prescribe" antibiotics particularly in consultations with Turkish immigrants. And so a qualitative approach was used to learn more about the socio-medical context of Turkish patients in regard to acute coughs. A German leaflet designed to improve the doctor-patient communication has been positively tested and then adapted for Turkish patients.</p> <p>Methods</p> <p>The original leaflet was first translated into Turkish. Then 57 patients belonging to 8 different GPs were interviewed about the leaflet using a semi-standardised script. The material was audio recorded, fully transcribed, and analysed by three independent researchers. As a first step a comprehensive content analysis was performed. Secondly, elements crucial to any Turkish version of the leaflet were identified.</p> <p>Results</p> <p>The interviews showed that the leaflets' messages were clearly understood by all patients irrespective of age, gender, and educational background. We identified no major problems in the perception of the translated leaflet but identified several minor points which could be improved. We found that patients were starting to reconsider their attitudes after reading the leaflet.</p> <p>Conclusion</p> <p>The leaflet successfully imparted relevant and new information to the target patients. A qualitative approach is a feasible way to prove general acceptance and provides additional information for its adaptation to medico-cultural factors.</p

    Collins and Sivers asymmetries in muonproduction of pions and kaons off transversely polarised proton

    Get PDF
    Measurements of the Collins and Sivers asymmetries for charged pions and charged and neutral kaons produced in semi-inclusive deep-inelastic scattering of high energy muons off transversely polarised protons are presented. The results were obtained using all the available COMPASS proton data, which were taken in the years 2007 and 2010. The Collins asymmetries exhibit in the valence region a non-zero signal for pions and there are hints of non-zero signal also for kaons. The Sivers asymmetries are found to be positive for positive pions and kaons and compatible with zero otherwise.Comment: 15 pages, 13 figures and 1 tabl

    Measurement of the charged-pion polarisability

    Get PDF
    The COMPASS collaboration at CERN has investigated pion Compton scattering, πγπγ\pi^-\gamma\rightarrow \pi^-\gamma, at centre-of-mass energy below 3.5 pion masses. The process is embedded in the reaction πNiπγ  Ni\pi^-\mathrm{Ni}\rightarrow\pi^-\gamma\;\mathrm{Ni}, which is initiated by 190\,GeV pions impinging on a nickel target. The exchange of quasi-real photons is selected by isolating the sharp Coulomb peak observed at smallest momentum transfers, Q2<0.0015Q^2<0.0015\,(GeV/cc)2^2. From a sample of 63\,000 events the pion electric polarisability is determined to be $\alpha_\pi\ =\ (\,2.0\ \pm\ 0.6_{\mbox{\scriptsize stat}}\ \pm\ 0.7_{\mbox{\scriptsize syst}}\,) \times 10^{-4}\,\mbox{fm}^3undertheassumption under the assumption \alpha_\pi=-\beta_\pi$, which relates the electric and magnetic dipole polarisabilities. It is the most precise measurement of this fundamental low-energy parameter of strong interaction, that has been addressed since long by various methods with conflicting outcomes. While this result is in tension with previous dedicated measurements, it is found in agreement with the expectation from chiral perturbation theory. An additional measurement replacing pions by muons, for which the cross-section behavior is unambigiously known, was performed for an independent estimate of the systematic uncertainty.Comment: Published version: 9 pages, 3 figures, 1 tabl
    corecore