97 research outputs found
Advanced spectroscopic investigation of colour centres in LiF crystals irradiated with monochromatic hard x-rays
Nominally-pure lithium fluoride (LiF) crystals were irradiated with monochromatic hard x-rays of energy 5, 7, 9 and 12 keV at the METROLOGIE beamline of the SOLEIL synchrotron facility, in order to understand the role of the selected x-ray energy on their visible photoluminescence (PL) response, which is used for high spatial resolution 2D x-ray imaging detectors characterized by a wide dynamic range. At the energies of 7 and 12 keV the irradiations were performed at five different doses corresponding to five uniformly irradiated areas, while at 5 and 9 keV only two irradiations at two different doses were carried out. The doses were planned in a range between 4 and 1.4 × 103 Gy (10.5 mJ cm−3 to 3.7 J cm−3), depending on the x-ray energy. After irradiation at the energies of 7 and 12 keV, the spectrally-integrated visible PL intensity of the F2 and F3+ colour centres (CCs) generated in the LiF crystals, carefully measured by fluorescence microscopy under blue excitation, exhibits a linear dependence on the irradiation dose in the investigated dose range. This linear behaviour was confirmed by the optical absorption spectra of the irradiated spots, which shows a similar linear behaviour for both the F2 and F3+ CCs, as derived from their overlapping absorption band at around 450 nm. At the highest x-ray energy, the average concentrations of the radiation-induced F, F2 and F3+ CCs were also estimated. The volume distributions of F2 defects in the crystals irradiated with 5 and 9 keV x-rays were reconstructed in 3D by measuring their PL signal using a confocal laser scanning microscope operating in fluorescence mode. On-going investigations are focusing on the results obtained through this z-scanning technique to explore the potential impact of absorption effects at the excitation laser wavelength
Demonstration and Comparison of Operation of Photomultiplier Tubes at Liquid Argon Temperature
Liquified noble gases are widely used as a target in direct Dark Matter
searches. Signals from scintillation in the liquid, following energy deposition
from the recoil nuclei scattered by Dark Matter particles (e.g. WIMPs), should
be recorded down to very low energies by photosensors suitably designed to
operate at cryogenic temperatures. Liquid Argon based detectors for Dark Matter
searches currently implement photo multiplier tubes for signal read-out. In the
last few years PMTs with photocathodes operating down to liquid Argon
temperatures (87 K) have been specially developed with increasing Quantum
Efficiency characteristics. The most recent of these, Hamamatsu Photonics Mod.
R11065 with peak QE up to about 35%, has been extensively tested within the R&D
program of the WArP Collaboration. During these testes the Hamamatsu PMTs
showed superb performance and allowed obtaining a light yield around 7
phel/keVee in a Liquid Argon detector with a photocathodic coverage in the 12%
range, sufficient for detection of events down to few keVee of energy
deposition. This shows that this new type of PMT is suited for experimental
applications, in particular for new direct Dark Matter searches with LAr-based
experiments
Lithium fluoride coloration by laser-plasma soft x-rays: A promising tool for X-ray microscopy and photonics
A new imaging detector for EUV or soft-X-ray radiation based on optically stimulated luminescence (OSL) of lithium fluoride (LiF) films or crystals is presented. The first micro-radiography images of biological samples and of meshes obtained on LiF using a laser-plasma source or an X-ray laser are shown, and (up to now) a resolution better than one micron is demonstrated. The dependence of the coloration density vs the deposited X-ray dose is considered and the advantages of this new diagnostic technique for both coherent and non-coherent EUV sources, compared with CCDs detectors, photographic films and photoresists are discussed. This new detector is extremely suitable for laser plasmas and for X-ray lasers sources
thermoluminescence in lif crystals and the role of impurities
Eight nominally pure lithium fluoride crystals, obtained from a single LiF crystal containing less than 100 ppm impurities, were irradiated by gamma-rays from a 60 Co source at room temperature, with doses from 8.4 to 2.5 x 10 5 Gy, but one at -60 °C. Optical density measurements were performed to investigate the radiation-induced color centres (CCs) and to evaluate their concentrations. Thermoluminescence (TL) glow curves were collected and simulated by a first-order kinetics approach, and from the best-fit procedure ten glow peaks (GPs) spanning from 100 to 450 °C were highlighted. A comparative analysis of GP intensities and CC concentrations as a function of the irradiation dose has questioned their association as obtained in previous measurements, showing the impurities, less than 10 18 cm -3 , still playing a predominant role in TL spectra. New measurements on LiF crystals more pure, at least an order of magnitude, are required to establish for sure the association of GPs to CCs
x ray imaging of bio medical samples using laser plasma based x ray sources and lif detector
This contribution to ECPD2019 is dedicated to the memory of Anatoly Faenov. During a period of approximately thirteen years 1994–2006, Anatoly and his wife Tatiana Pikuz (simply "Tania" for friends), accepting the frequent invitations of the National Institute for Nuclear Physics (INFN) and of the Italian National Agency for New Technologies, Energy and Sustainable Economic Development (ENEA), cooperated with many Italian research laboratories dedicated to EUV and soft X-ray generation, spread in different towns (L'Aquila, Frascati, Milano, Padova, Pisa, Roma, etc.). In spite of the fact that they could stay in Italy only about one or two months per year, their activity was so intense that more than 50 peer- reviewed publications were generated from their experimental and theoretical work (just considering only the results obtained at L'Aquila and Tor Vergata—Rome Universities and at the ENEA Research Center of Frascati), without mentioning the cultural atmosphere that they stimulated in the field of Science and Humanity. The numerous experimental spectra obtained at ENEA by means of their spherically bent mica spectrometers, together with the corresponding theoretical simulations performed in Moscow, allowed to study the changing role of different excitations mechanisms for various plasma conditions, and to characterize at best the ENEA laser-plasma source for different applications: polychromatic and monochromatic micro-radiography of dried biological samples at 1 keV, soft X-ray contact microscopy (SXCM) of living cells in the water-window spectral region, spectroscopy of hollow atoms, etc. In this memorial paper, the main results of biological samples imaging on lithium fluoride (LiF) detectors, obtained with the ENEA and Tor Vergata University laser-plasma sources, are presented. In particular, the improvement of the micro-radiography and of the SXCM techniques obtained after moving from photoresist detectors and photographic films to lithium fluoride (LiF) detectors are discussed, for both dried and wet biological samples
Multi-Determinants Analysis of Molecular Alterations for Predicting Clinical Benefit to EGFR-Targeted Monoclonal Antibodies in Colorectal Cancer
KRAS mutations occur in 35-45% of metastatic colorectal cancers (mCRC) and preclude responsiveness to EGFR-targeted therapy with cetuximab or panitumumab. However, less than 20% patients displaying wild-type KRAS tumors achieve objective response. Alterations in other effectors downstream of the EGFR, such as BRAF, and deregulation of the PIK3CA/PTEN pathway have independently been found to give rise to resistance. We present a comprehensive analysis of KRAS, BRAF, PIK3CA mutations, and PTEN expression in mCRC patients treated with cetuximab or panitumumab, with the aim of clarifying the relative contribution of these molecular alterations to resistance.We retrospectively analyzed objective tumor response, progression-free (PFS) and overall survival (OS) together with the mutational status of KRAS, BRAF, PIK3CA and expression of PTEN in 132 tumors from cetuximab or panitumumab treated mCRC patients. Among the 106 non-responsive patients, 74 (70%) had tumors with at least one molecular alteration in the four markers. The probability of response was 51% (22/43) among patients with no alterations, 4% (2/47) among patients with 1 alteration, and 0% (0/24) for patients with > or =2 alterations (p<0.0001). Accordingly, PFS and OS were increasingly worse for patients with tumors harboring none, 1, or > or =2 molecular alteration(s) (p<0.001).When expression of PTEN and mutations of KRAS, BRAF and PIK3CA are concomitantly ascertained, up to 70% of mCRC patients unlikely to respond to anti-EGFR therapies can be identified. We propose to define as 'quadruple negative', the CRCs lacking alterations in KRAS, BRAF, PTEN and PIK3CA. Comprehensive molecular dissection of the EGFR signaling pathways should be considered to select mCRC patients for cetuximab- or panitumumab-based therapies
From data to practice: brain meningioma treatment in elderly patients – a survey of the Italian Society of Neurosurgery (SINch®) and systematic review and meta-analysis
The management of meningioma in elderly patients (MEP) presents a complex and evolving challenge. Data available offer conflicting information on treatment options and complications. This survey aimed to examine the current approach to MEP, comparing the national profile to data in the current literature. A survey addressing the treatments options and management of meningioma in elderly was designed on behalf of SINch (R) (Societa Italiana di Neurochirurgia) and sent via email to all Chiefs of Neurosurgical Departments. The survey remained open for responses from May 5th, 2022, until November 21st, 2022. A search of the literature published between January 2000 and March 2023, in accordance to PRISMA guidelines, was included. A total of 51 Neurosurgical centers participated in the survey. The caseload profile of each center influences the choice of treatment selection (Stereotactic Radiosurgery versus open surgery) (p = 0.01) and the consolidated practice of discussing cases within a multidisciplinary group (p = 0.02). The pooled meta-analysis demonstrated a significant increased risk in the elderly group for permanent deficits (p < 0.00001), postoperative infections (p = 0.0004) and hemorrhage (p = 0.0001), perioperative mortality (p < 0.00001), and medical complications (p < 0.00001) as compared to the young population. This study presents the initial comprehensive analysis of the existing trends in the surgical management of MEP in Italy. The significant variation in practices primarily stems from the absence of standardized guidelines. While most centers have adopted an integrated approach, there is a need to promote a multidisciplinary care model. Prospective studies are needed to gather robust evidence in this clinical setting
OPTICAL COATINGS BASED ON SiO2 AND TiO2 LAYERS AND CHARACTERIZED BY COMPLEMENTARY SURFACE TECHNIQUES
- …