573 research outputs found

    Nanoparticle formation and dynamics in a complex (dusty) plasma: from the plasma ignition to the afterglow.

    Get PDF
    Complex (dusty) plasmas are a subject of growing interest. They areionized gases containing charged dust particles. In capacitively-coupled RF discharges, dust growth can occur naturally and two methods can be used to grow dust particles: chemically active plasmas or sputtering. The growth of dust particles in argon discharges by RF sputtering and the effect of dust particles on theplasma have been investigated from the plasma ignition to the afterglow. It was shown that plasma and discharge parameters are greatly affected by the dust particles. Furthermore, plasma instabilities can be triggered by the presence of the dust particles. These instabilities can be due to dust particle growth or they can be instabilities of a well established dust cloud filling the interelectrode space. When the discharge is switched off, the dust particles act like a sink for the charge carrier and consequently affect the plasma losses. It was shown that the dust particles do keep residual chargeswhich values are greatly affected by the diffusion of the charge carriers and especially the transition from ambipolar to free diffusion

    Small coronary calcifications are not detectable by 64-slice contrast enhanced computed tomography

    Get PDF
    Recently, small calcifications have been associated with unstable plaques. Plaque calcifications are both in intravascular ultrasound (IVUS) and multi-slice computed tomography (MSCT) easily recognized. However, smaller calcifications might be missed on MSCT due to its lower resolution. Because it is unknown to which extent calcifications can be detected with MSCT, we compared calcification detection on contrast enhanced MSCT with IVUS. The coronary arteries of patients with myocardial infarction or unstable angina were imaged by 64-slice MSCT angiography and IVUS. The IVUS and MSCT images were registered and the arteries were inspected on the presence of calcifications on both modalities independently. We measured the length and the maximum circumferential angle of each calcification on IVUS. In 31 arteries, we found 99 calcifications on IVUS, of which only 47 were also detected on MSCT. The calcifications missed on MSCT (n = 52) were significantly smaller in angle (27° ± 16° vs. 59° ± 31°) and length (1.4 ± 0.8 vs. 3.7 ± 2.2 mm) than those detected on MSCT. Calcifications could only be detected reliably on MSCT if they were larger than 2.1 mm in length or 36° in angle. Half of the calcifications seen on the IVUS images cannot be detected on contrast enhanced 64-slice MSCT angiography images because of their size. The limited resolution of MSCT is the main reason for missing small calcifications

    Diagnostic accuracy of computed tomography coronary angiography in patients with a zero calcium score

    Get PDF
    To evaluate the diagnostic accuracy of 64-slice CT coronary angiography (CT-CA) for the detection of significant coronary artery stenosis in patients with zero on the Agatston Calcium Score (CACS). We enrolled 279 consecutive patients (96 male, mean age 48±12 years) with suspected coronary artery disease. Patients were symptomatic (n=208) or asymptomatic (n=71), and underwent conventional coronary angiography (CAG). For CT-CA we administered an IV bolus of 100 ml of iodinated contrast material. CT-CA was compared to CAG using a threshold for significant stenosis of ≤50%. The prevalence of disease demonstrated at CAG was 15% (1.4% in asymptomatic). The population at CAG showed no or non-significant disease in 85% (238/279), single vessel disease in 9% (25/279), and multi-vessel disease in 6% (16/279). Sensitivity, specificity, and positive and negative predictive values of CT-CA vs. CAG on the patient level were 100%, 95%, 76%, and 100% in the overall population and 100%, 100%, 100%, and 100% in asymptomatic patients, respectively. CT-CA proves high diagnostic performance in patients with or without symptoms and with zero CACS. The prevalence of significant disease detected by CT-CA was not negligible in asymptomatic patients. The role of CT-CA in asymptomatic patients remains uncertain

    An embedded interfacial network stabilizes inorganic CsPbI<sub>3</sub> perovskite thin films

    Get PDF
    The black perovskite phase of CsPbI(3) is promising for optoelectronic applications; however, it is unstable under ambient conditions, transforming within minutes into an optically inactive yellow phase, a fact that has so far prevented its widespread adoption. Here we use coarse photolithography to embed a PbI(2)-based interfacial microstructure into otherwise-unstable CsPbI(3) perovskite thin films and devices. Films fitted with a tessellating microgrid are rendered resistant to moisture-triggered decay and exhibit enhanced long-term stability of the black phase (beyond 2.5 years in a dry environment), due to increasing the phase transition energy barrier and limiting the spread of potential yellow phase formation to structurally isolated domains of the grid. This stabilizing effect is readily achieved at the device level, where unencapsulated CsPbI(3) perovskite photodetectors display ambient-stable operation. These findings provide insights into the nature of phase destabilization in emerging CsPbI(3) perovskite devices and demonstrate an effective stabilization procedure which is entirely orthogonal to existing approaches

    Computed tomography segmental calcium score (SCS) to predict stenosis severity of calcified coronary lesions

    Get PDF
    To estimate the probability of ≥50 % coronary stenoses based on computed tomography (CT) segmental calcium score (SCS) and clinical factors. The Institutional Review Board approved the study. A training sample of 201 patients underwent CT calcium scoring and conventional coronary angiography (CCA). All patients consented to undergo CT before CCA after being informed of the additional radiation dose. SCS and calcification morphology were assessed in individual coronary segments. We explored the predictive value of patient’s symptoms, clinical history, SCS and calcification morphology. We developed a prediction model in the training sample based on these variables then tested it in an independent test sample. The odds ratio (OR) for ≥50 % coronary stenosis was 1.8-fold greater (p = 0.006) in patients with typical chest pain, twofold (p = 0.014) greater in patients with acute coronary syndromes, twofold greater (p < 0.001) in patients with prior myocardial infarction. Spotty calcifications had an OR for ≥50 % stenosis 2.3-fold (p < 0.001) greater than the absence of calcifications, wide calcifications 2.7-fold (p < 0.001) greater, diffuse calcifications 4.6-fold (p < 0.001) greater. In middle segments, each unit of SCS had an OR 1.2-fold (p < 0.001) greater than in distal segments; in proximal segments the OR was 1.1-fold greater (p = 0.021). The ROC curve area of the prediction model was 0.795 (0.95 confidence interval 0.602–0.843). Validation in a test sample of 201 independent patients showed consistent diagnostic performance. In conjunction with calcification morphology, anatomical location, patient’s symptoms and clinical history, SCS can be helpful to estimate the probability of ≥50 % coronary stenosis

    Is there a role for CT coronary angiography in patients with symptomatic angina? Effect of coronary calcium score on identification of stenosis

    Get PDF
    Present guidelines discourage the use of CT coronary angiography (CTCA) in symptomatic angina patients. We examined the relation between coronary calcium score (CS) and the performance of CTCA in patients with stable and unstable angina in order to understand under which conditions CTCA might be a gate-keeper to conventional coronary angiography (CCA) in such patients. We included 360 patients between 50 and 70 years old with stable and unstable angina who were clinically referred for CCA irrespective of CS. Patients received CS and CCTA on 64-slice scanners in a multicenter cross-sectional trial. The institutional review board approved the study. Diagnostic performance of CTCA to detect or rule out significant coronary artery disease was calculated on a per patient level in pre-defined CS categories. The prevalence of significant coronary artery disease strongly increased with CS. Negative CTCA were associated with a negative likelihood ratio of <0.1 independent of CS. Positive CTCA was associated with a high positive likelihood ratio of 9.4 if CS was <10. However, for higher CS the positive likelihood ratio never exceeded 3.0 and for CS >400 it decreased to 1.3. In the 62 (17%) patients with CS <10, CTCA reliably identified the 42 (68%) of these patients without significant CAD, at no false negative CTCA scans. In symptomatic angina patients, a negative CTCA reliably excludes significant CAD but the additional value of CTCA decreases sharply with CS >10 and especially with CS >400. In patients with CS <10, CTCA provides excellent diagnostic performance

    Incremental value of the CT coronary calcium score for the prediction of coronary artery disease

    Get PDF
    Objectives:: To validate published prediction models for the presence of obstructive coronary artery disease (CAD) in patients with new onset stable typical or atypical angina pectoris and to assess the incremental value of the CT coronary calcium score (CTCS). Methods:: We searched the literature for clinical prediction rules for the diagnosis of obstructive CAD, defined as≥50% stenosis in at least one vessel on conventional coronary angiography. Significant variables were re-analysed in our dataset of 254 patients with logistic regression. CTCS was subsequently included in the models. The area under the receiver operating characteristic curve (AUC) was calculated to assess diagnostic performance. Results:: Re-analysing the variables used by Diamond & Forrester yielded an AUC of 0.798, which increased to 0.890 by adding CTCS. For Pryor, Morise 1994, Morise 1997 and Shaw the AUC increased from 0.838 to 0.901, 0.831 to 0.899, 0.840 to 0.898 and 0.833 to 0.899. CTCS significantly improved model performance in each model. Conclusions:: Validation demonstrated good diagnostic performance across all models. CTCS improves the prediction of the presence of obstructive CAD, independent of clinical predictors, and should be considered in its diagnostic work-up. © 2010 The Author(s)
    corecore