323 research outputs found

    Nanoscale mechanical properties of lipid bilayers and their relevance in biomembrane organization and function

    Get PDF
    The mechanical properties of biological systems are emerging as fundamental in determining their functional activity. For example, cells continuously probe their environment by applying forces and, at the same time, are exposed to forces produced by the same environment. Also in biological membranes, the activity of membrane related proteins are affected by the overall mechanical properties of the hosting environment. Traditionally, the mesoscopic mechanical properties of lipid bilayers have been studied by micropipette aspiration techniques. In recent years, the possibility of probing mechanical properties of lipid bilayers at the nanoscale has been promoted by the force spectroscopy potentiality of Atomic Force Microscopes (AFM). By acquiring force-curves on supported lipid bilayers (SLBs) it is possible to probe the mechanical properties on a scale relevant to the interaction between membrane proteins and lipid bilayers and to monitor changes of these properties as a result of a changing environment. Here, we review a series of force spectroscopy experiments performed on SLBs with an emphasis on the functional consequences the measured mechanical properties can have on membrane proteins. We also discuss the force spectroscopy experiments on SLBs in the context of theories developed for dynamic force spectroscopy experiments with the aim to extract the kinetic and energetic description of the process of membrane rupture

    Demonstration of an electrostatic-shielded cantilever

    Full text link
    The fabrication and performances of cantilevered probes with reduced parasitic capacitance starting from a commercial Si3N4 cantilever chip is presented. Nanomachining and metal deposition induced by focused ion beam techniques were employed in order to modify the original insulating pyramidal tip and insert a conducting metallic tip. Two parallel metallic electrodes deposited on the original cantilever arms are employed for tip biasing and as ground plane in order to minimize the electrostatic force due to the capacitive interaction between cantilever and sample surface. Excitation spectra and force-to-distance characterization are shown with different electrode configurations. Applications of this scheme in electrostatic force microscopy, Kelvin probe microscopy and local anodic oxidation is discussed.Comment: 4 pages and 3 figures. Submitted to Applied Physics Letter

    A co-ultramicronized palmitoylethanolamide/luteolin composite mitigates clinical score and disease-relevant molecular markers in a mouse model of experimental autoimmune encephalomyelitis

    Get PDF
    Background: Persistent and/or recurrent inflammatory processes are the main factor leading to multiple sclerosis (MS) lesions. The composite ultramicronized palmitoylethanolamide, an endogenous N-acylethanolamine, combined with the flavonoid luteolin, PEALut, have been found to exert neuroprotective activities in experimental models of spinal and brain injury and Alzheimer disease, as well as a clinical improvement in human stroke patients. Furthermore, PEALut enhances the expression of different myelin proteins in oligodendrocyte progenitor cells suggesting that this composite might have protective effects in MS experimental models. Methods: The mouse model of experimental autoimmune encephalomyelitis (EAE) based on active immunization with a fragment of myelin oligodendrocyte glycoprotein (MOG35-55) was used. The daily assessment of clinical score and the expression of serum amyloid A (SAA1), proinflammatory cytokines TNF-\u3b1, IL-1\u3b2, IFN-\u3b3, and NLRP3 inflammasome, as well as TLR2, Fpr2, CD137, CD3-\u3b3, and TCR-\u3b6 chain, heterodimers that form T cell surface glycoprotein (TCR), and cannabinoid receptors CB1, CB2, and MBP, were evaluated in the brainstem and cerebellum at different postimmunization days (PIDs). Results: Vehicle-MOG35-55-immunized (MOG35-55) mice developed ascending paralysis which peaked several days later and persisted until the end of the experiment. PEALut, given intraperitoneally daily starting on day 11 post-immunization, dose-dependently improved clinical score over the range 0.1-5 mg/kg. The mRNA expression of SAA1, TNF-\u3b1, IL-1\u3b2, IFN-\u3b3, and NLRP3 were significantly increased in MOG35-55 mice at 14 PID. In MOG35-55 mice treated with 5 mg /kg PEALut, the increase of SAA1, TNF- \u3b1, IL-1\u3b2, and IFN-\u3b3transcripts at 14 PID was statistically downregulated as compared to vehicle-MOG35-55 mice (p < 0.05). The expression of TLR2, Fpr2, CD137, CD3-\u3b3, TCR-\u3b6 chain, and CB2 receptors showed a significant upregulation in vehicle-MOG35-55 mice at 14 PID. Instead, CB1 and MBP transcripts have not changed in expression at any time. In MOG/PEALut-treated mice, TLR2, Fpr2, CD137, CD3-\u3b3, TCR-\u3b6 chain, and CB2 mRNAs were significantly downregulated as compared to vehicle MOG35-55 mice. Conclusions: The present results demonstrate that the intraperitoneal administration of the composite PEALut significantly reduces the development of clinical signs in the MOG35-55 model of EAE. The dose-dependent improvement of clinical score induced by PEALut was associated with a reduction in transcript expression of the acute-phase protein SAA1, TNF-\u3b1, IL-1\u3b2, IFN-\u3b3, and NLRP3 proinflammatory proteins and TLR2, Fpr2, CD137, CD3-\u3b3, TCR-\u3b6 chain, and CB2 receptors

    live crack damage detection with local strain measurement on solid bodies subjected to hydrodynamic loading

    Get PDF
    Abstract The interaction of water free surface with solid bodies is object of interest in several mechanical, ocean, aerospace and civil engineering problems. The presence of impulsive loading and large local deformation leads to complex coupled dynamics. The possibility of live monitoring of these body could provide information about damage detection and fatigue life estimation. The definition of appropriate signal processing and modeling tools enabling the extraction of useful information from distributed sensing signals is a relevant scientific challenge. On the basis of previous works by some of the authors, this paper deals with the application of a method for real-time deformed shape reconstruction of solid bodies subjected to impulsive loadings using distributed numerically generated strain measurements signals, such as those produced by Fiber Bragg Grating (FBG) sensors. A numerical study is carried out considering a simplified model of the problem of hull structures subjected to hydrodynamic loading. The hull, analyzed in a simplified section, has been studied both in healthy condition and with the presence of crack damages. The potential for detecting, localizing and quantifying this damage using the reconstruction algorithm is investigated, by leveraging the proposed concept of control sensors, that are FBG sensors used for comparing reconstructed strains and/or displacements with measured quantities. The positioning and number of sensors and the effect of sensor layout on damage detection is investigated, with the aim of developing a real time damage detection methodology

    Dynamic Force Spectroscopy on Supported Lipid Bilayers: Effect ofTemperature and Sample Preparation

    Get PDF
    Biological membranes are constantly exposed to forces. The stress-strain relation in membranes determines thebehavior of many integral membrane proteins or other membrane related-proteins that show a mechanosensitive behavior. Here, we studied by force spectroscopy the behavior of supported lipid bilayers (SLBs) subjected to forces perpendicular to their plane. We measured the lipid bilayer mechanical properties and the force required for the punch-through event characteristic of atomic force spectroscopy on SLBs as a function of the interleaflet coupling. We found that for an uncoupled bilayer, the overall tip penetration occurs sequentially through the two leaflets, giving rise to two penetration events. In the case of a bilayer with coupled leaflets, penetration of the atomic force microscope tip always occurred in a single step. Considering the dependence of the jump-through force value on the tip speed, we also studied the process in the context of dynamic force spectroscopy (DFS). We performed DFS experiments by changing the temperature and cantilever spring constant, and analyzed the resultsin the context of the developed theories for DFS. We found that experiments performed at different temperatures and withdifferent cantilever spring constants enabled a more effective comparison of experimental data with theory in comparisonwith previously published data

    Îł-Hemolysin oligomeric structure and effect of its formation on supported lipid bilayers: An AFM Investigation.

    Get PDF
    γ-Hemolysins are bicomponent β-barrel pore forming toxins produced by Staphylococcus aureus as water-soluble monomers, which assemble into oligomeric pores on the surface of lipid bilayers. Here, after investigating the oligomeric structure of γ-hemolysins on supported lipid bilayers (SLBs) by atomic force microscopy (AFM), we studied the effect produced by this toxin on the structure of SLBs. We found that oligomeric structures with different number of monomers can assemble on the lipid bilayer being the octameric form the most stable one. Moreover, in this membrane model we found that γ-hemolysins can form clusters of oligomers inducing a curvature in the lipid bilayer, which could probably enhance the aggressiveness of these toxins at high concentrations

    Quantum Zeno and anti-Zeno effects by indirect measurement with finite errors

    Full text link
    We study the quantum Zeno effect and the anti-Zeno effect in the case of `indirect' measurements, where a measuring apparatus does not act directly on an unstable system, for a realistic model with finite errors in the measurement. A general and simple formula for the decay rate of the unstable system under measurement is derived. In the case of a Lorentzian form factor, we calculate the full time evolutions of the decay rate, the response of the measuring apparatus, and the probability of errors in the measurement. It is shown that not only the response time but also the detection efficiency plays a crucial role. We present the prescription for observing the quantum Zeno and anti-Zeno effects, as well as the prescriptions for avoiding or calibrating these effects in general experiments.Comment: 4 pages, 3 figure

    Adhesion mechanisms of the contact interface of TiO2 nanoparticles in films and aggregates

    Get PDF
    Fundamental knowledge about the mechanisms of adhesion between oxide particles with diameters of few nanometers is impeded by the difficulties associated with direct measurements of contact forces at such a small size scale. Here we develop a strategy based on AFM force spectroscopy combined with all-atom molecular dynamics simulations to quantify and explain the nature of the contact forces between 10 nm small TiO2 nanoparticles. The method is based on the statistical analysis of the force peaks measured in repeated approaching/retracting loops of an AFM cantilever into a film of nanoparticle agglomerates and relies on the in-situ imaging of the film stretching behavior in an AFM/TEM setup. Sliding and rolling events first lead to local rearrangements in the film structure when subjected to tensile load, prior to its final rupture caused by the reversible detaching of individual nanoparticles. The associated contact force of about 2.5 nN is in quantitative agreement with the results of molecular dynamics simulations of the particle–particle detachment. We reveal that the contact forces are dominated by the structure of water layers adsorbed on the particles’ surfaces at ambient conditions. This leads to nonmonotonous force–displacement curves that can be explained only in part by classical capillary effects and highlights the importance of considering explicitly the molecular nature of the adsorbates

    Serum amyloid A primes microglia for ATP-dependent interleukin-1\u3b2 release

    Get PDF
    Acute-phase response is a systemic reaction to environmental/inflammatory insults and involves production of acute-phase proteins, including serum amyloid A (SAA). Interleukin-1\u3b2 (IL-1\u3b2), a master regulator of neuroinflammation produced by activated inflammatory cells of the myeloid lineage, in particular microglia, plays a key role in the pathogenesis of acute and chronic diseases of the peripheral nervous system and CNS. IL-1\u3b2 release is promoted by ATP acting at the purinergic P2X7 receptor (P2X7R) in cells primed with toll-like receptor (TLR) ligands

    Electron Transport Properties of Single-Molecule-Bearing Multiple Redox Levels Studied by EC-STM/STS

    Get PDF
    Multielectron systems as possible components of molecular electronics devices are attracting compelling experimental and theoretical interest. Here we studied by electrochemical scanning tunneling techniques (EC-STMicroscopy and EC-STSpectroscopy) the electron transport properties of a redox molecule endowed with two redox levels, namely, the hydroquinone/quinone (H2Q/Q) couple. By forming self-assembled monolayers on Au(111) of oligo-phenylene-vinylene (OPV) derivatized H2Q/Q moieties, we were able to explore the features of the tunneling current/overpotential relation in the EC-STS setup. The behavior of the tunneling current sheds light onto the mechanism of electron transport involving the redox levels of the H2Q/Q redox pair coupled to tip and substrate electrodes
    • …
    corecore