42 research outputs found
Le calcul parallĂšle des plus courts chemins temporels
Mémoire numérisé par la Direction des bibliothÚques de l'Université de Montréal
The ARIA-MASK-airÂź approach
Funding Information: The authors thank Ms VĂ©ronique Pretschner for submitting the paper. MASKâair has been supported by CharitĂ© UniversitĂ€tsmedizin Berlin, EU grants (EU Structural and Development Funds Languedoc Roussillon and Region PACA; POLLAR: EIT Health; Twinning: EIP on AHA; Twinning DHE: H2020; Catalyse: Horizon Europe) and educational grants from MylanâViatris, ALK, GSK, Novartis, StallergĂšnesâGreer and Uriach. None for the study. Âź Publisher Copyright: © 2023 The Authors. Clinical and Translational Allergy published by John Wiley & Sons Ltd on behalf of European Academy of Allergy and Clinical Immunology.MASK-airÂź, a validated mHealth app (Medical Device regulation Class IIa) has enabled large observational implementation studies in over 58,000 people with allergic rhinitis and/or asthma. It can help to address unmet patient needs in rhinitis and asthma care. MASK-airÂź is a Good Practice of DG SantĂ© on digitally-enabled, patient-centred care. It is also a candidate Good Practice of OECD (Organisation for Economic Co-operation and Development). MASK-airÂź data has enabled novel phenotype discovery and characterisation, as well as novel insights into the management of allergic rhinitis. MASK-airÂź data show that most rhinitis patients (i) are not adherent and do not follow guidelines, (ii) use as-needed treatment, (iii) do not take medication when they are well, (iv) increase their treatment based on symptoms and (v) do not use the recommended treatment. The data also show that control (symptoms, work productivity, educational performance) is not always improved by medications. A combined symptom-medication score (ARIA-EAACI-CSMS) has been validated for clinical practice and trials. The implications of the novel MASK-airÂź results should lead to change management in rhinitis and asthma.publishersversionpublishe
TOPAZ1, a Novel Germ Cell-Specific Expressed Gene Conserved during Evolution across Vertebrates
BACKGROUND: We had previously reported that the Suppression Subtractive Hybridization (SSH) approach was relevant for the isolation of new mammalian genes involved in oogenesis and early follicle development. Some of these transcripts might be potential new oocyte and granulosa cell markers. We have now characterized one of them, named TOPAZ1 for the Testis and Ovary-specific PAZ domain gene. PRINCIPAL FINDINGS: Sheep and mouse TOPAZ1 mRNA have 4,803 bp and 4,962 bp open reading frames (20 exons), respectively, and encode putative TOPAZ1 proteins containing 1,600 and 1653 amino acids. They possess PAZ and CCCH domains. In sheep, TOPAZ1 mRNA is preferentially expressed in females during fetal life with a peak during prophase I of meiosis, and in males during adulthood. In the mouse, Topaz1 is a germ cell-specific gene. TOPAZ1 protein is highly conserved in vertebrates and specifically expressed in mouse and sheep gonads. It is localized in the cytoplasm of germ cells from the sheep fetal ovary and mouse adult testis. CONCLUSIONS: We have identified a novel PAZ-domain protein that is abundantly expressed in the gonads during germ cell meiosis. The expression pattern of TOPAZ1, and its high degree of conservation, suggests that it may play an important role in germ cell development. Further characterization of TOPAZ1 may elucidate the mechanisms involved in gametogenesis, and particularly in the RNA silencing process in the germ lin
ARIA digital anamorphosis: Digital transformation of health and care in airway diseases from research to practice
Digital anamorphosis is used to define a distorted image of health and care that may be viewed correctly using digital tools and strategies. MASK digital anamorphosis represents the process used by MASK to develop the digital transformation of health and care in rhinitis. It strengthens the ARIA change management strategy in the prevention and management of airway disease. The MASK strategy is based on validated digital tools. Using the MASK digital tool and the CARAT online enhanced clinical framework, solutions for practical steps of digital enhancement of care are proposed
Pressure-dependent hemodynamic effect of continuous positive airway pressure in severe chronic heart failure: A case series
International audienc
CPAP telemonitoring can track CheyneâStokes respiration and detect serious cardiac events: The AlertApnĂ©e Study
International audienceBackground and objective: Case reports have suggested that continuous positive airway pressure (CPAP) telemonitoring can detect the onset of acute cardiac events such as decompensated heart failure (HF) or atrial fibrillation through an increase in the apnoea-hypopnoea index (AHI) and onset of Cheyne-Stokes Respiration (CSR). This study addressed whether long-term remote CPAP treatment telemonitoring revealing CSR can help detect serious cardiac events (SCEs) in obstructive sleep apnoea (OSA) patients.Methods: This monocentric prospective cohort study included adults receiving CPAP therapy for OSA with daily telemonitoring. Any sudden increase in AHI generated an alert for the home healthcare provider to download CPAP data to identify CSR. A medical consultation was scheduled if CSR was detected.Results: We included 555 adults (412 men; 57% with known cardiovascular comorbidities). During the 1-year follow-up, 78 CSR episodes were detected in 74 patients (CSR+). The main conditions associated with incident CSR were HF (24 patients [30.8%]), ventilatory instability (21, 26.9%), leaks (13, 16.7%), medications inducing central apnoeas (baclofen, ticagrelor, opioids) (7, 9.0%), arrhythmias (6, 7.7%) and renal failure (2, 2.6%). Fifteen (20.3%) CSR+ patients had a confirmed SCE. In univariable analysis, a CSR episode increased the risk of an SCE by 13.8-fold (5.7-35.6) (p < 0.0001), with an adjusted OR of 5.7 (2.0-16.8) in multivariable analysis.Conclusion: Long-term telemonitoring of patients on CPAP treatment can alert CSR episodes and allows early detection of SCEs in patients with or without known cardiac comorbidities
Feasibility of Type 3 Polygraphy for Evaluating Leak Determinants in CPAP-Treated OSA Patients A Step Toward Personalized Leak Management
International audienceBackground: Unintentional leaks (ULs) are frequent adverse effects in CPAP-treated patients. We previously published a novel methodology for analyzing the determinants of UL using polysomnography. We now propose a simplified recording system using a type 3 polygraphic device (Somnolter; Nomics S.A.).Research question: (1) To describe individual UL determinants provided by the Somnolter software in automatic-CPAP-treated OSA patients; (2) To subsequently describe the clinical consensus of four physicians on how to manage each individual UL situation.Study design and methods: Somnoler recordings performed under nasal automatic-CPAP were automatically analyzed with APIOS software. For each polygraphic recording, APIOS provided the OR and the CIs for potential determinants of UL: mouth opening, CPAP pressure, body position, and mandibular oscillation. Based on these results, each of four physicians was asked to choose one of four strategies: (1) increase or decrease therapeutic pressure; (2) change nasal mask for oro-nasal mask/chinstrap; (3) favor a nonsupine or supine position; (4) no action for individual leak management. Subsequently, a meeting was held to determine a consensus choice for each individual case.Results: Seventy-eight consecutive patients underwent home-polygraphy with Somnolter. Fifty recordings were analyzed (16 females; 65 [57-75] years of age; BMI = 31.1 [27.4-35.3]). Individual diagnosis of UL was routinely feasible. The determinants of UL were heterogeneous in the population, and diagnosis of UL was not feasible in 10 patients. Based on the results from this analysis, we established consensus leak management strategies at the individual level. The average Cohen Îș coefficient for the four raters was 0.58. Pressure modification was proposed in 36% of patients, no action in 24%, installation of a facial mask/chinstrap in 22%, and positional treatment in 18%.Interpretation: The use of type 3 polygraphy for characterizing leak determinants in patients treated with nasal automatic-CPAP is feasible in routine practice. Leak determinants are patient specific. Interrater concordance for determining individual leak management strategies demonstrated a "fair" level of agreement.Trial registry: ClinicalTrials.gov; No.: NCT03381508; URL: www.clinicaltrials.gov)
Machine learning and geometric morphometrics to predict obstructive sleep apnea from 3D craniofacial scans
International audienc
Heat-moulded versus custom-made mandibular advancement devices for obstructive sleep apnoea: a randomised non-inferiority trial
International audienceRationale Custom-made mandibular advancement devices (MADs) are reported as providing higher efficacy rates compared with thermoplastic heat-moulded MADs but at the price of higher costs and treatment delays.Objective To determine whether a thermoplastic heat-moulded titratable MAD (ONIRIS; ONIRIS SAS, Rueil Malmaison, France) is non-inferior to a custom-made acrylic titratable MAD (TALI; ONIRIS SAS, Rueil Malmaison, France) for obstructive sleep apnoea (OSA).Methods We conducted a multicentre, open, randomised controlled trial of patients with OSA refusing or not tolerating continuous positive airway pressure (CPAP). Participants were randomly assigned to a thermoplastic heat-moulded titratable device or a custom-made acrylic device for 2 months with stratification by centre and OSA severity. The non-inferiority primary outcome was a â„50% reduction in apnoeaâhypopnoea index (AHI) or achieving AHI <10 events/hour at 2 months. The non-inferiority margin was preset as a difference between groups of 20% for the primary outcome in the per-protocol analysis.Main results Of 198 patients (mean age 51 [SD, 12] years; 138 [72.6%] men; mean body mass index 26 [SD, 2.7] kg/m2; mean AHI 26.6/hour [SD, 10.4]), 100 received TALI and 98 ONIRIS. In per-protocol analysis, the response rate was 51.7% in the TALI group versus 53.6% in the ONIRIS group (absolute difference 1.9%; 90% CI: 11% to 15%, within the non-inferiority margin). Effectiveness was the same for severity, symptoms, quality of life and blood pressure reduction. Patients in ONIRIS group reported more side effects and adherence was slightly better with TALI.Conclusion In patients with OSA refusing or not tolerating CPAP, the thermoplastic heat-moulded titratable MAD was non-inferior in the short-term to the custom-made acrylic MAD
Toulouse dykes: reducing failure hazard combining structural reinforcement works and organization measures
Toulouse dykes include 16 km of various types of dykes and flood gates and stoplogs, belonging to several owners including Toulouse City and French State (DDT31) that own about 13 km. The Toulouse dykes Hazard Study has been made in 2014-2015. The study includes: