12 research outputs found

    Frozen-hydrated chromatin from metaphase chromosomes has an interdigitated multilayer structure

    No full text
    Cryo‐electron tomography and small‐angle X‐ray scattering were used to investigate the chromatin folding in metaphase chromosomes. The tomographic 3D reconstructions show that frozen‐hydrated chromatin emanated from chromosomes is planar and forms multilayered plates. The layer thickness was measured accounting for the contrast transfer function fringes at the plate edges, yielding a width of ~ 7.5 nm, which is compatible with the dimensions of a monolayer of nucleosomes slightly tilted with respect to the layer surface. Individual nucleosomes are visible decorating distorted plates, but typical plates are very dense and nucleosomes are not identifiable as individual units, indicating that they are tightly packed. Two layers in contact are ~ 13 nm thick, which is thinner than the sum of two independent layers, suggesting that nucleosomes in the layers interdigitate. X‐ray scattering of whole chromosomes shows a main scattering peak at ~ 6 nm, which can be correlated with the distance between layers and between interdigitating nucleosomes interacting through their faces. These observations support a model where compact chromosomes are composed of many chromatin layers stacked along the chromosome axis.This work was supported in part by MINECO research grant BFU2010-18939, European Union (EU) and Horizon 2020 through grant West-Life (EINFRA-2015-1, Proposal: 675858), and a by a UAB-PIF predoctoral fellowship to AC. Cryo-ET experiments at Max-Planck-Institute of Biochemistry (Martinsried) and image processing at National Center of Biotechnology (Madrid) were funded by Instruct (PID250, PID2115), part of the European Strategy Forum on Research Infrastructures (ESFRI) and supported by national member subscriptions

    Image formation in cellular X-ray microscopy

    No full text
    Soft X-ray Tomographic (TomoX) microscopy has become a reality in the last years. The resolution range of this technique nicely fits between confocal and electron microscopies and will play a key role in the elucidation of the organization between the molecular and the organelle levels. In fact, it offers the possibility of imaging three-dimensional structures of hydrated biological specimens near their native state without chemical pre-treatment. Ideally, TomoX reconstructs the specimen absorption coefficients from projections of this specimen, but, unfortunately, X-ray micrographs are only an approximation to projections of the specimen, resulting in inaccuracies if a tomographic reconstruction is performed without explicitly incorporating these approximations. In an attempt to mitigate some of these inaccuracies, we develop in this work an image formation model within the approximation of assuming incoherent illumination. © 2012 Elsevier Inc.This work was funded by the Spanish Ministerio de Ciencia e Innovación (CSD2006-0023, BFU2009-09331, BIO2010-16566, ACI2009-1022, ACI2010-1088) and NSF grant 1114901. C.O. Sorzano is a recipient of a Ramón y Cajal fellowship financed by the European Social Fund and the Ministerio de Educación y Ciencia. Joaquin Oton is supported by a Juan de la Cierva Research Fellowship from the Ministerio de Ciencia e Innovación.Peer Reviewe

    Measurement of local resolution in electron tomography

    No full text
    Resolution (global and local) is one of the most reported metrics of quality measurement in Single Particle Analysis (SPA). However, in electron tomography, the situation is different and its computation is not straightforward. Typically, resolution estimation is global and, therefore, reduces the assessment of a whole tomogram to a single number. However, it is known that tomogram quality is spatially variant. Still, up to our knowledge, a method to estimate local quality metrics in tomography is lacking. This work introduces MonoTomo, a method developed to estimate locally in a tomogram the highest reliable frequency component, expressed as a form of local resolution. The fundamentals lie in a local analysis of the density map via monogenic signals, which, in analogy to MonoRes, allows for local estimations. Results with experimental data show that the local resolution range that MonoTomo casts agrees with reported resolution values for experimental data sets, with the advantage of providing a local estimation. A range of applications of MonoTomo are suggested for further exploration.The author would like to express their gratitude to Dr. J.J. Fernandez for his interest, following and advice on this work. The authors would like to acknowledge economical support from The Spanish Ministry of Economy and Competitiveness through Grants BIO2016-76400-R(AEI/FEDER, UE), the “Comunidad Autónoma de Madrid” through Grant: S2017/BMD-3817, and the European Union (EU) and Horizon 2020 through grant EOSCpilot (INFRADEV-04-2016, Proposal: 739563), INSTRUCT - ULTRA (INFRADEV-03-2016-2017, Proposal: 731005), EOSC-LIFE (INFRAEOSC-04-2018, Proposal: 824087) and HighResCells (ERC-2018-SyG, Proposal: 810057). The authors acknowledge the support and the use of resources of Instruct-ERIC

    The chaperonin CCT controls T cell receptor–driven 3D configuration of centrioles

    No full text
    © 2020 The Authors.T lymphocyte activation requires the formation of immune synapses (IS) with antigen-presenting cells. The dynamics of membrane receptors, signaling scaffolds, microfilaments, and microtubules at the IS determine the potency of T cell activation and subsequent immune response. Here, we show that the cytosolic chaperonin CCT (chaperonin-containing TCP1) controls the changes in reciprocal orientation of the centrioles and polarization of the tubulin dynamics induced by T cell receptor in T lymphocytes forming an IS. CCT also controls the mitochondrial ultrastructure and the metabolic status of T cells, regulating the de novo synthesis of tubulin as well as posttranslational modifications (poly-glutamylation, acetylation, Δ1 and Δ2) of αβ-tubulin heterodimers, fine-tuning tubulin dynamics. These changes ultimately determine the function and organization of the centrioles, as shown by three-dimensional reconstruction of resting and stimulated primary T cells using cryo-soft x-ray tomography. Through this mechanism, CCT governs T cell activation and polarity.Cryo-SXT work was supported by ALBA Synchrotron standard proposals 2015021148 and 2016021638 to F.J.C., N.B.M.-C., and J.M.V. This study was supported by grants SAF2017-82886-R (to F.S.-M.), PID2019-105872GB I00/AEI/10.13039/501100011033 (AEI/FEDER, UE), BFU2016-75984 (to J.M.V.), and BIO2015-67580-P and PGC2018-097019-B-I00 (to J.V.) from the Spanish Ministry of Economy and Competitiveness (MINECO), grants INFLAMUNE-S2017/BMD-23671 (to F.S.-M.) and P2018/NMT-4389 (to J.M.V.) from the Comunidad de Madrid, ERC-2011-AdG 294340-GENTRIS (to F.S.-M.), a 2019 grant from the Ramón Areces Foundation “Ciencias de la Vida y la Salud” and a 2018 grant from Ayudas Fundación BBVA a Equipos de Investigación Científica (to F.S.-M.), and grants PRB3 (IPT17/0019-ISCIII-SGEFI/ERDF), the Fundació Marató TV3 (grant 122/C/2015), and “La Caixa” Banking Foundation (HR17-00016 to FSM and HR17-00247 to J.V.). D.T. is supported by a PhD fellowship from La Caixa Foundation. Work in the Vernos lab was supported by the grant CSD2006-00023 from the Spanish Ministry of Science and Innovation and grants BFU2012-37163 and BFU2015-68726-P from the Spanish Ministry of Economy and Competitiveness. The CRG acknowledges support of the Spanish Ministry of Science and Innovation to the EMBL partnership, the Centro de Excelencia Severo Ochoa, and the CERCA Programme/Generalitat de Catalunya. CIBER Cardiovascular (Fondo de Investigación Sanitaria del Instituto de Salud Carlos III and co-funding by Fondo Europeo de Desarrollo Regional FEDER). The Centro Nacional de Investigaciones Cardiovasculares (CNIC) is supported by the Spanish Ministry of Economy and Competitiveness (MINECO) and the Pro-CNIC Foundation and is a Severo Ochoa Center of Excellence (MINECO award SEV-2015-0505). The Centro Nacional de Biotecnología (CNB) is a Severo Ochoa Center of Excellence (MINECO award SEV 2017-0712)

    Validation of electron microscopy initial models via small angle X-ray scattering curves

    No full text
    [Motivation]: Cryo electron microscopy (EM) is currently one of the main tools to reveal the structural information of biological macromolecules. The re-construction of three-dimensional (3D) maps is typically carried out following an iterative process that requires an initial estimation of the 3D map to be refined in subsequent steps. Therefore, its determination is key in the quality of the final results, and there are cases in which it is still an open issue in single particle analysis (SPA). Small angle X-ray scattering (SAXS) is a well-known technique applied to structural biology. It is useful from small nanostructures up to macromolecular ensembles for its ability to obtain low resolution information of the biological sample measuring its X-ray scattering curve. These curves, together with further analysis, are able to yield information on the sizes, shapes and structures of the analyzed particles. [Results]: In this paper, we show how the low resolution structural information revealed by SAXS is very useful for the validation of EM initial 3D models in SPA, helping the following refinement process to obtain more accurate 3D structures. For this purpose, we approximate the initial map by pseudo-atoms and predict the SAXS curve expected for this pseudo-atomic structure. The match between the predicted and experimental SAXS curves is considered as a good sign of the correctness of the EM initial map.This work was supported by the Spanish Ministry of Economy and Competitiveness through Grants BIO2016-76400-R(AEI/FEDER, UE), Comunidad Autonoma de Madrid through Grant: S2017/BMD-3817, Instituto de Salud Carlos III, PT13/0001/0009, PT17/0009/0010 and European Union (EU) and Horizon 2020 through Grants: Elixir—EXCELERATE (INFRADEV-3-2015, Proposal: 676559), iNEXT (INFRAIA-1-2014-2015, Proposal: 653706) and INSTRUCT—ULTRA (INFRADEV-03-2016-2017, Proposal: 731005)

    C. Literaturwissenschaft.

    No full text

    Performance of a modular ton-scale pixel-readout liquid argon time projection chamber

    No full text
    The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmic ray events collected in the spring of 2021. We use this sample to demonstrate the imaging performance of the charge and light readout systems as well as the signal correlations between the two. We also report argon purity and detector uniformity measurements, and provide comparisons to detector simulations

    Performance of a modular ton-scale pixel-readout liquid argon time projection chamber

    No full text
    International audienceThe Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmic ray events collected in the spring of 2021. We use this sample to demonstrate the imaging performance of the charge and light readout systems as well as the signal correlations between the two. We also report argon purity and detector uniformity measurements, and provide comparisons to detector simulations

    Performance of a modular ton-scale pixel-readout liquid argon time projection chamber

    No full text
    International audienceThe Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmic ray events collected in the spring of 2021. We use this sample to demonstrate the imaging performance of the charge and light readout systems as well as the signal correlations between the two. We also report argon purity and detector uniformity measurements, and provide comparisons to detector simulations
    corecore