257 research outputs found

    Evaluation of Plasma Damage to Thin Gate Oxides

    Get PDF
    Capacitance-Voltage (C-V) arid Conductance-Voltage (G-V) measurements were performed to characterize field induced charges in thin (300A) oxides subjected to a RF generated oxygen plasma used to remove photoresist. Results based on C-V curves indicate a -4.6V threshold voltage shift for capacitors exposed to the RF plasma as compared to capacitors without plasma processing. Results based on tunnel current measurements were inconclusive

    A framework for priority effects

    Full text link
    History of species arrival can influence plant community assembly. In this issue of the Journal of Vegetation Science, Sarneel et al. show that the strength of such historical contingency, or priority effects, varies with soil moisture in riparian plants. We discuss this study within a theoretical framework describing how and when priority effects occur via destabilizing and equalizing mechanisms.History of species arrival can influence plant community assembly. In this issue of the Journal of Vegetation Science, Sarneel et al. show that the strength of such historical contingency, or priority effects, varies with soil moisture in riparian plants. We discuss this study within a theoretical framework describing how and when priority effects occur via destabilizing and equalizing mechanisms.Peer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/122424/1/jvs12434.pdfhttp://deepblue.lib.umich.edu/bitstream/2027.42/122424/2/jvs12434_am.pd

    Thick GEM-like multipliers - a simple solution for large area UV-RICH detectors

    Full text link
    We report on the properties of thick GEM-like (THGEM) electron multipliers made of 0.4 mm thick double-sided Cu-clad G-10 plates, perforated with a dense hexagonal array of 0.3 mm diameter drilled holes. Photon detectors comprising THGEMs coupled to semi-transparent CsI photocathodes or reflective ones deposited on the THGEM surface were studied with Ar/CO2 (70:30), Ar/CH4 (95:5), CH4 and CF4. Gains of ~100000 or exceeding 1000000 were reached with single- or double-THGEM, respectively; the signals have 5-10 ns rise times. The electric field configurations at the THGEM electrodes result in an efficient extraction of photoelectrons and their focusing into the holes; this occurs already at rather low gains, below 100. These detectors, with single-photon sensitivity and with expected sub-millimeter localization, can operate at MHz/mm2 rates. We discuss their prospects for large-area UV-photon imaging for RICH.Comment: 5 pages, 6 figure

    Calcium supplementation and risk of dementia in women with cerebrovascular disease

    Get PDF
    OBJECTIVE: To determine whether calcium supplementation is associated with the development of dementia in women after a 5-year follow-up. METHODS: This was a longitudinal population-based study. The sample was derived from the Prospective Population Study of Women and H70 Birth Cohort Study in Gothenburg, Sweden, and included 700 dementia-free women aged 70–92 years. At baseline in 2000–2001, and at follow-up in 2005–2006, the women underwent comprehensive neuropsychiatric and somatic examinations. A CT scan was performed in 447 participants at baseline. Information on the use and dosage of calcium supplements was collected. Dementia was diagnosed according to DSM-III-R criteria. RESULTS: Women treated with calcium supplements (n = 98) were at a higher risk of developing dementia (odds ratio [OR] 2.10, 95% confidence interval [CI] 1.01–4.37, p = 0.046) and the subtype stroke-related dementia (vascular dementia and mixed dementia) (OR 4.40, 95% CI 1.54–12.61, p = 0.006) than women not given supplementation (n = 602). In stratified analyses, calcium supplementation was associated with the development of dementia in groups with a history of stroke (OR 6.77, 95% CI 1.36–33.75, p = 0.020) or presence of white matter lesions (OR 2.99, 95% CI 1.28–6.96, p = 0.011), but not in groups without these conditions. CONCLUSIONS: Calcium supplementation may increase the risk of developing dementia in elderly women with cerebrovascular disease. Because our sample was relatively small and the study was observational, these findings need to be confirmed

    First observation of Cherenkov rings with a large area CsI-TGEM-based RICH prototype

    Full text link
    We have built a RICH detector prototype consisting of a liquid C6F14 radiator and six triple Thick Gaseous Electron Multipliers (TGEMs), each of them having an active area of 10x10 cm2. One triple TGEM has been placed behind the liquid radiator in order to detect the beam particles, whereas the other five have been positioned around the central one at a distance to collect the Cherenkov photons. The upstream electrode of each of the TGEM stacks has been coated with a 0.4 micron thick CsI layer. In this paper, we will present the results from a series of laboratory tests with this prototype carried out using UV light, 6 keV photons from 55Fe and electrons from 90Sr as well as recent results of tests with a beam of charged pions where for the first time Cherenkov Ring images have been successfully recorded with TGEM photodetectors. The achieved results prove the feasibility of building a large area Cherenkov detector consisting of a matrix of TGEMs.Comment: Presented at the International Conference NDIP-11, Lyon,July201

    Study of GEM-like detectors with resistive electrodes for RICH applications

    Full text link
    We have developed prototypes of GEM-like detectors with resistive electrodes to be used as RICH photodetectors equipped with CsI photocathodes. The main advantages of these detectors are their intrinsic spark protection and possibility to operate at high gain (~10E5) in many gases including poorly quenched ones, allowing for the adoption of windowless configurations in which the radiator gas is also used in the chamber. Results of systematic studies of the resistive GEMs combined with CsI photocathodes are presented: its quantum efficiency, rate characteristics, long-term stability, etc. On the basis of the obtained results, we believe that the new detector will be a promising candidate for upgrading the ALICE RICH detectorComment: Presented at the International Workshop RICH-2007, Trieste, Italy, October 200

    Advances in Thick GEM-like gaseous electron multipliers. Part I: atmospheric pressure operation

    Full text link
    Thick GEM-like (THGEM) gaseous electron multipliers are made of standard printed-circuit board perforated with sub-millimeter diameter holes, etched at their rims. Effective gas multiplication factors of 100000 and 10000000 and fast pulses in the few nanosecond rise-time scale were reached in single- and cascaded double-THGEM elements, in atmospheric-pressure standard gas mixtures with single photoelectrons. High single-electron detection efficiency is obtained in photon detectors combining THGEMs and semitransparent UV-sensitive CsI photocathodes or reflective ones deposited on the top THGEM face; the latter benefits of a reduced sensitivity to ionizing background radiation. Stable operation was recorded with photoelectron fluxes exceeding MHz/mm2. The properties and some potential applications of these simple and robust multipliers are discussed.Comment: 41 pages, 27 figures. Submitted to Nucl. Instr. and Meth. A, Dec 21, 200

    Ion-induced effects in GEM & GEM/MHSP gaseous photomultipliers for the UV and the visible spectral range

    Get PDF
    We report on the progress in the study of cascaded GEM and GEM/MHSP gas avalanche photomultipliers operating at atmospheric pressure, with CsI and bialkali photocathodes. They have single-photon sensitivity, ns time resolution and good localization properties. We summarize operational aspects and results, with the highlight of a high-gain stable gated operation of a visible-light device. Of particular importance are the results of a recent ion-backflow reduction study in different cascaded multipliers, affecting the detector's stability and the photocathode's liftime. We report on the significant progress in ion-blocking and provide first results on bialkali-photocathode aging under gas multiplication.Comment: 6 pages, 8 figure

    Introducing a true internal standard for the Comet assay to minimize intra- and inter-experiment variability in measures of DNA damage and repair

    Get PDF
    The Comet assay (CA) is a sensitive/simple measure of genotoxicity. However, many features of CA contribute variability. To minimize these, we have introduced internal standard materials consisting of ‘reference’ cells which have their DNA substituted with BrdU. Using a fluorescent anti-BrdU antibody, plus an additional barrier filter, comets derived from these cells could be readily distinguished from the ‘test’-cell comets, present in the same gel. In experiments to evaluate the reference cell comets as external and internal standards, the reference and test cells were present in separate gels on the same slide or mixed together in the same gel, respectively, before their co-exposure to X-irradiation. Using the reference cell comets as internal standards led to substantial reductions in the coefficient of variation (CoV) for intra- and inter-experimental measures of comet formation and DNA damage repair; only minor reductions in CoV were noted when the reference and test cell comets were in separate gels. These studies indicate that differences between individual gels appreciably contribute to CA variation. Further studies using the reference cells as internal standards allowed greater significance to be obtained between groups of replicate samples. Ultimately, we anticipate that development will deliver robust quality assurance materials for CA

    Interface Engineering Routes for a Future CMOS Ge-based Technology

    Get PDF
    We present an overview study of two germanium interface engineering routes, firstly a germanate formation via La2O3 and Y2O3, and secondly a barrier layer approach using Al2O3 and Tm2O3. The interfacial composition, uniformity, thickness, band gap, crystallinity, absorption features and valence band offset are determined using X-ray photoelectron spectroscopy, ultra violet variable angle spectroscopic ellipsometry, and high resolution transmission electron microscopy. The correlation of these results with electrical characterization data make a case for Ge interface engineering with rare-earth inclusion as a viable route to achieve high performance Ge CMOS.</jats:p
    • 

    corecore