184 research outputs found

    Qualitative Assessment of the PAX Good Behavior Game Implementation

    Get PDF
    This paper reports on a program evaluation of the PAX Good Behavior Game (GBG), an evidence-based practice intervention designed to create a nurturing environment conducive to learning in elementary schools. To evaluate and improve the PAX Good Behavior Game, a focus group was conducted at the end of the 2016-17 academic year. A total of ten teachers and school administrators from schools who implemented the PAX Good Behavior Game (PAX professionals) participated in a focus group session and provided feedback about the program. Focus group questions assessed four program objectives: (1) environmental change, (2) personal well-being and stress levels, (3) engagement with parents, and (4) networking with other PAX professionals. Results indicated that the PAX GBG decreased problematic classroom behaviors, provided more instructional time for teachers, and generated public interest of the program in the home and community

    Electronic health records to facilitate clinical research

    Get PDF
    Electronic health records (EHRs) provide opportunities to enhance patient care, embed performance measures in clinical practice, and facilitate clinical research. Concerns have been raised about the increasing recruitment challenges in trials, burdensome and obtrusive data collection, and uncertain generalizability of the results. Leveraging electronic health records to counterbalance these trends is an area of intense interest. The initial applications of electronic health records, as the primary data source is envisioned for observational studies, embedded pragmatic or post-marketing registry-based randomized studies, or comparative effectiveness studies. Advancing this approach to randomized clinical trials, electronic health records may potentially be used to assess study feasibility, to facilitate patient recruitment, and streamline data collection at baseline and follow-up. Ensuring data security and privacy, overcoming the challenges associated with linking diverse systems and maintaining infrastructure for repeat use of high quality data, are some of the challenges associated with using electronic health records in clinical research. Collaboration between academia, industry, regulatory bodies, policy makers, patients, and electronic health record vendors is critical for the greater use of electronic health records in clinical research. This manuscript identifies the key steps required to advance the role of electronic health records in cardiovascular clinical research

    Biolimus-A9 polymer-free coated stent in high bleeding risk patients with acute coronary syndrome: a Leaders Free ACS sub-study.

    Get PDF
    Aims: Although a true clinical challenge, high bleeding risk patients with an acute coronary syndrome (ACS) undergoing percutaneous coronary intervention (PCI) have never been specifically studied. Leaders Free ACS, a pre-specified Leaders Free sub-study, determined efficacy, and safety of a combination of 1-month dual anti-platelet therapy (DAPT) with implantation of either a polymer-free Biolimus-A9-coated stent (BA9-DCS) or a bare-metal stent (BMS) in these patients. Methods and results: Leaders Free included 2466 patients undergoing PCI who had at least 1 of 13 pre-defined factors for an increased bleeding risk. Of these, 659 ACS patients were included in this analysis (BA9-DCS 330, BMS 329). At 12-month follow-up, treatment with the BA9-DCS was more effective (clinically driven target-lesion revascularization 3.9 vs. 9.0%, P = 0.009) and safer (cumulative incidence of cardiac death, myocardial infarction, or definite or probable stent thrombosis 9.3 vs. 18.5%, P = 0.001), driven by significantly lower rates of cardiac mortality (3.4 vs. 6.9%, P = 0.049) and myocardial infarction (6.9 vs. 13.8%, P = 0.005). Conclusion: We believe that the results of this sub-analysis from the Leaders Free trial are likely to significantly impact clinical practice for high bleeding risk patients presenting with an ACS: the use of a BMS can, in our view, no longer be recommended, and, given the paucity of available data for second-generation DES with shortened DAPT in these patients, the BA9-DCS should currently be considered as the device with the strongest evidence to support its use for this indication

    Inferring structural variant cancer cell fraction.

    Get PDF
    We present SVclone, a computational method for inferring the cancer cell fraction of structural variant (SV) breakpoints from whole-genome sequencing data. SVclone accurately determines the variant allele frequencies of both SV breakends, then simultaneously estimates the cancer cell fraction and SV copy number. We assess performance using in silico mixtures of real samples, at known proportions, created from two clonal metastases from the same patient. We find that SVclone's performance is comparable to single-nucleotide variant-based methods, despite having an order of magnitude fewer data points. As part of the Pan-Cancer Analysis of Whole Genomes (PCAWG) consortium, which aggregated whole-genome sequencing data from 2658 cancers across 38 tumour types, we use SVclone to reveal a subset of liver, ovarian and pancreatic cancers with subclonally enriched copy-number neutral rearrangements that show decreased overall survival. SVclone enables improved characterisation of SV intra-tumour heterogeneity

    Antimicrobial peptides, disease severity and exacerbations in bronchiectasis

    Get PDF
    Rationale: Recently a frequent exacerbator phenotype has been described in bronchiectasis, but the underlying biological mechanisms are unknown. Antimicrobial peptides (AMPs) are important in host defence against microbes but can be proinflammatory in chronic lung disease. Objectives: To determine pulmonary and systemic levels of AMP and their relationship with disease severity and future risk of exacerbations in bronchiectasis. Methods: A total of 135 adults with bronchiectasis were prospectively enrolled at three European centres. Levels of cathelicidin LL-37, lactoferrin, lysozyme and secretory leucocyte protease inhibitor (SLPI) in serum and sputum were determined at baseline by ELISA. Patients were followed up for 12 months. We examined the ability of sputum AMP to predict future exacerbation risk. Measurements and main results: AMP levels were higher in sputum than in serum, suggesting local AMP release. Patients with more severe disease at baseline had dysregulation of airway AMP. Higher LL-37 and lower SLPI levels were associated with Bronchiectasis Severity Index, lower FEV1 (forced expiratory volume in 1 s) and Pseudomonas aeruginosa infection. Low SLPI levels were also associated with the exacerbation frequency at baseline. During follow-up, higher LL-37 and lower SLPI levels were associated with a shorter time to the next exacerbation, whereas LL-37 alone predicted exacerbation frequency over the next 12 months. Conclusions: Patients with bronchiectasis showed dysregulated sputum AMP levels, characterised by elevated LL-37 and reduced SLPI levels in the frequent exacerbator phenotype. Elevated LL-37 and reduced SLPI levels are associated with Pseudomonas aeruginosa infection and can predict future risk of exacerbations in bronchiectasis

    En Attendant Centiloid

    Get PDF
    Aims: Test the robustness of a linear regression transformation of semiquantitative values from different Aβ tracers into a single continuous scale. Study Design: Retrospective analysis. Place and Duration of Study: PET imaging data acquired in Melbourne and Perth, Australia, between August 2006 and May 2014. Methodology: Aβ imaging in 633 participants was performed with four different radiotracers: flutemetamol (n=267), florbetapir (n=195), florbetaben (n=126) and NAV4694 (n=45). SUVR were generated with the methods recommended for each tracer, and classified as high (Aβ+) or low (Aβ-) based on their respective thresholds. Linear regression transformation based on reported head-to-head comparisons of each tracer with PiB was applied to each tracer result. Each tracer native classification was compared with the classification derived from the transformed data into PiB-like SUVR units (or BeCKeT: Before the Centiloid Kernel Transformation) using 1.50 as a cut-off. Results: Misclassification after transformation to PiB-like SUVR compared to native classification was extremely low with only 3/267 (1.1%) of flutemetamol, 1/195 (0.5%) of florbetapir, 1/45 (2.2%) of NAV4694, and 1/126 (0.8%) of florbetaben cases assigned into the wrong category. When misclassification occurred (Conclusion: While a definitive transformation into centesimal units is being established, application of linear regression transformations provide an interim, albeit robust, way of converting results from different Aβ imaging tracers into more familiar PiB-like SUVR units

    2-Year Outcomes of High Bleeding Risk Patients After Polymer-Free Drug-Coated Stents.

    Get PDF
    BACKGROUND: A 1-year follow-up, polymer-free metallic stent coated with biolimus-A9 followed by 1-month dual antiplatelet therapy is safer and more effective than a bare-metal stent (BMS) for patients with high risk of bleeding. OBJECTIVES: This study analyzed 2-year outcomes to determine whether these benefits are maintained. METHODS: In a prospective, multicenter, double-blind trial, we randomized 2,466 high bleeding risk patients to receive a drug-coated stent (DCS) or a BMS followed by 1-month dual antiplatelet therapy. The primary safety endpoint was a composite of cardiac death, myocardial infarction, or stent thrombosis. The primary efficacy endpoint was clinically driven target lesion revascularization. RESULTS: At 2 years, the primary safety endpoint had occurred in 147 DCS and 180 BMS patients (15.3%) (hazard ratio: 0.80; 95% confidence interval: 0.64 to 0.99; p = 0.039). Clinically driven target lesion revascularization occurred for 77 DCS and 136 BMS patients (12.0%) (hazard ratio: 0.54; 95% confidence interval: 0.41 to 0.72; p 75 years, anemia, raised plasma creatinine, and planned long-term anticoagulation. Correlates of the primary safety endpoint were age, anemia, congestive heart failure, multivessel disease, number of stents implanted, and use of a BMS rather than a DCS. CONCLUSIONS: Safety and efficacy benefits of DCS over BMS were maintained for 2 years in high bleeding risk patients. Rates of major bleeding and coronary thrombotic events were no different and were associated with a substantial and comparable mortality risk. (A Prospective Randomized Comparison of the BioFreedom Biolimus A9 Drug Coated Stent Versus the Gazelle Bare Metal Stent in Patients With High Risk of Bleeding [LEADERS FREE]; NCT01623180)

    Associations between sleep disturbance, cognitive functioning and work disability in Bipolar Disorder

    Get PDF
    Bipolar Disorder (BD) is associated with impairment in a number of areas including poor work functioning, often despite the remission of mood symptoms. The present study aimed to examine the role of sleep disturbance and cognitive functioning in occupational impairment in BD. Twenty-four euthymic BD participants and 24 healthy control participants completed a week of prospective assessment of sleep disruption via self-report and actigraphy, a battery of neuropsychological tests of executive functioning, working memory, and verbal learning, and assessments of work functioning. BD participants experienced significantly poorer cognitive functioning as well as greater months of unemployment and greater incidence of being fired than controls. Moderation analyses revealed that both poor sleep and cognitive functioning were associated with poor work performance in BD participants, but not control participants. Sleep and cognitive functioning may be impaired in euthymic BD and are associated with poor work functioning in this population. More research should be conducted to better understand how sleep and cognitive functioning may interact in BD
    corecore