318 research outputs found

    Influence of Cold Sensation on Plantar Tactile Sensation for Young Females

    Get PDF
    Cold sensation (CS) is a cold feeling on people’s hands or feet; this is a well-known health problem for young females. Plantar tactile sensation plays an important role in postural control and is affected by skin temperature. However, there is no research focusing on the relation between CS and plantar tactile sensation. In this study, we address the question of whether the CS influences plantar tactile sensation. 32 non cold sensation (Non-CS) and 31 cold sensation (CS) young females have participated in this research. A tactile sensation test was conducted at five plantar points (first and fifth toes, first and fifth metatarsal heads, and heel). Experimental results showed that although there was no significant difference at the first and fifth toes as well as the first metatarsal head and heel, the sensation threshold at the fifth metatarsal head for CS was lower than the Non-CS (21.61 ± 8.10 μm, 27.42 ± 11.02 μm respectively, p < 0.05).  It was concluded that plantar tactile sensation for young females with cold sensation was more sensitive compared to healthy subjects

    Flexible Multifunctional Sensors for Wearable and Robotic Applications

    Get PDF
    This review provides an overview of the current state-of-the-art of the emerging field of flexible multifunctional sensors for wearable and robotic applications. In these application sectors, there is a demand for high sensitivity, accuracy, reproducibility, mechanical flexibility, and low cost. The ability to empower robots and future electronic skin (e-skin) with high resolution, high sensitivity, and rapid response sensing capabilities is of interest to a broad range of applications including wearable healthcare devices, biomedical prosthesis, and human–machine interacting robots such as service robots for the elderly and electronic skin to provide a range of diagnostic and monitoring capabilities. A range of sensory mechanisms is examined including piezoelectric, pyroelectric, piezoresistive, and there is particular emphasis on hybrid sensors that provide multifunctional sensing capability. As an alternative to the physical sensors described above, optical sensors have the potential to be used as a robot or e-skin; this includes sensory color changes using photonic crystals, liquid crystals, and mechanochromic effects. Potential future areas of research are discussed and the challenge for these exciting materials is to enhance their integration into wearables and robotic applications.</p

    Design of electron correlation effects in interfaces and nanostructures

    Full text link
    We propose that one of the best grounds for the materials design from the viewpoint of {\it electron correlation} such as ferromagnetism, superconductivity is the atomically controlled nanostructures and heterointerfaces, as theoretically demonstrated here from three examples with first-principles calculations: (i) Band ferromagnetism in a purely organic polymer of five-membered rings, where the flat-band ferromagnetism due to the electron-electron repulsion is proposed. (ii) Metal-induced gap states (MIGS) of about one atomic monolayer thick at insulator/metal heterointerfaces, recently detected experimentally, for which an exciton-mechanism superconductivity is considered. (iii) Alkali-metal doped zeolite, a class of nanostructured host-guest systems, where ferromagnetism has been experimentally discovered, for which a picture of the "supercrystal" composed of "superatoms" is proposed and Mott-insulator properties are considered. These indicate that design of electron correlation is indeed a promising avenue for nanostructures and heterointerfaces.Comment: to be published in Proc. 7th Int. Conf. on Atomically Controlled Surfaces, Interfaces and Nanostructures, Nara, Nov. 2003, 14 pages, 10 figure

    Neuromelanin‐Sensitive Magnetic Resonance Imaging Using DANTE Pulse

    Get PDF
    BACKGROUND: Neuromelanin-sensitive magnetic resonance imaging techniques have been developed but currently require relatively long scan times. The aim of this study was to assess the ability of black-blood delay alternating with nutation for tailored excitation-prepared T1-weighted variable flip angle turbo spin echo (DANTE T1-SPACE), which provides relatively high resolution with a short scan time, to visualize neuromelanin in the substantia nigra pars compacta (SNpc). METHODS: Participants comprised 49 healthy controls and 25 patients with Parkinson's disease (PD). Contrast ratios of SNpc and hyperintense SNpc areas, which show pixels brighter than thresholds, were assessed between DANTE T1-SPACE and T1-SPACE in healthy controls. To evaluate the diagnostic ability of DANTE T1-SPACE, the contrast ratios and hyperintense areas were compared between healthy and PD groups, and receiver operating characteristic analyses were performed. We also compared areas under the curve (AUCs) between DANTE T1-SPACE and the previously reported gradient echo neuromelanin (GRE-NM) imaging. Each analysis was performed using original images in native space and images transformed into Montreal Neurological Institute space. Values of P < 0.05 were considered significant. RESULTS: DANTE T1-SPACE showed significantly higher contrast ratios and larger hyperintense areas than T1-SPACE. On DANTE T1-SPACE, healthy controls showed significantly higher contrast ratios and larger hyperintense areas than patients with PD. Hyperintense areas in native space analysis achieved the best AUC (0.94). DANTE T1-SPACE showed AUCs as high as those of GRE-NM. CONCLUSIONS: DANTE T1-SPACE successfully visualized neuromelanin of the SNpc and showed potential for evaluating PD. © 2020 The Authors. Movement Disorders published by Wiley Periodicals LLC on behalf of International Parkinson and Movement Disorder Society

    Two-Minute Quantitative Susceptibility Mapping From Three-Dimensional Echo-Planar Imaging: Accuracy, Reliability, and Detection Performance in Patients With Cerebral Microbleeds

    Get PDF
    Objectives: The aim of this study was to assess the accuracy, reliability, and cerebral microbleed (CMB) detection performance of 2-minute quantitative susceptibility mapping (QSM) from 3-dimensional echo-planar imaging (3D-EPI). Materials and Methods: Gadolinium phantom study was conducted using 3D-EPI, single–echo time (TE), and multi-TE gradient-recalled echo (GRE) sequences on two 3-T magnetic resonance (MR) scanners to assess the accuracy between measured and theoretical susceptibility values. The institutional review board approved this prospective study, and 40 healthy volunteers were enrolled with written consent between April 2018 and October 2019. Each underwent 3D-EPI, single-TE, and multi-TE GRE sequences consecutively on one 3-T MR scanner, and QSMs were calculated to assess the reliability of 3D-EPI QSM. Intraclass correlation coefficient (ICC), linear regression, and Bland-Altman plots were calculated. Patients with CMB who underwent both 3D-EPI and GRE QSM scans were retrospectively enrolled. Two radiologists evaluated images independently, and Cohen κ coefficients were calculated to compare CMB detection performance. Results: Phantom study showed excellent validity of 3D-EPI QSM on both MR scanners: Skyra, R2 = 0.996, P < 0.001, ICC = 0.997, mean difference, −2 ppb (95% confidence interval [CI], −45 to 40 ppb); Prisma, R2 = 0.992, P < 0.001, ICC = 0.988, mean difference, 15 ppb (95% CI, −67 to 97 ppb). A human study of 40 healthy volunteers (59 ± 13 years, 25 women) showed excellent reliability with 3D-EPI QSM for both single-TE and multi-TE GRE (R2 = 0.981, P < 0.001, ICC = 0.988; R2 = 0.983, P < 0.001, ICC = 0.990, respectively), supported by a Bland-Altman mean difference of 4 ppb (95% CI, −15 to 23 ppb) for single-TE GRE and 3 ppb (95% CI, −15 to 20 ppb) for multi-TE GRE. The CMB detection performance evaluation from 38 patients (51 ± 20 years, 20 women) showed almost perfect agreement between 3D-EPI and GRE QSM for both raters (κ = 0.923 and 0.942, P < 0.001). Conclusions: Faster QSM from 3D-EPI demonstrated excellent accuracy, reliability, and CMB detection performance

    マッキ ジンフゼン トウニョウビョウ カンジャ ニオケル ケットウ カンリ シヒョウ : HbA1c ノ モンダイテン

    Get PDF
    We have investigated the validity of HbA1c values measured as the index of glycemic controls in diabetics with end-stage renal disease(ESRD). HbA1c levels for diabetics with ESRD undergoing haemodialysis were lower than indicated by their blood glucose control. However, the changes in glycated albumin in relation to the blood glucose control in the dialysis patients matched those in diabetics without renal dysfunction. Diabetics with stage4or5chronic kidney disease(CKD)not on haemodialysis had significantly lower values of HbA1c and shorter RBC lifespan compared with patients without renal dysfunction. When assessing blood glucose control based solely on HbA1c, erroneous result may be obtained in diabetics with ESRD

    Insertable inductively coupled volumetric coils for MR microscopy in a human 7T MR system

    Get PDF
    PURPOSE: To demonstrate the capability of insertable inductively coupled volumetric coils for MR microscopy in a human 7T MR system. METHODS: Insertable inductively coupled volume coils with diameters of 26 and 64 mm (D26 and D64 coils) targeted for monkey and mouse brain specimen sizes were designed and fabricated. These coils were placed inside the imaging volume of a transmit/receive knee coil without wired connections to the main system. Signal-to-noise ratio (SNR) evaluations were conducted with and without the insertable coils, and the g-factor maps of parallel imaging (PI) were also calculated for the D64 coil. Brain specimens were imaged using 3D T 2 ∗ -weighted images with spatial resolution of isotropic 50 and 160 μm using D26 and D64 coils, respectively. RESULTS: Relative average (SD) SNRs compared with knee coil alone were 12.54 (0.30) and 2.37 (0.05) at the center for the D26 and D64 coils, respectively. The mean g-factors of PI with the D64 coil for the factor of 2 were less than 1.1 in the left-right and anterior-posterior directions, and around 1.5 in the superior-inferior direction or when the PI factor of 3 was used. Acceleration in two directions showed lower g-factors but suffered from intrinsic low SNR. Representative T 2 ∗ -weighted images of the specimen showed structural details. CONCLUSION: Inductively coupled small diameter coils insertable to the knee coil demonstrated high SNR and modest PI capability. The concept was successfully used to visualize fine structures of the brain specimen. The insertable coils are easy to handle and enable MR microscopy in a human whole-body 7T MRI system

    Gate-induced band ferromagnetism in an organic polymer

    Full text link
    We propose that a chain of five-membered rings (polyaminotriazole) should be ferromagnetic with an appropriate doping that is envisaged to be feasible with an FET structure. The ferromagnetism is confirmed by a spin density functional calculation, which also shows that ferromagnetism survives the Peierls instability. We explain the magnetism in terms of Mielke and Tasaki's flat-band ferromagnetism with the Hubbard model. This opens a new possibility of band ferromagnetism in purely organic polymers.Comment: 4 pages, 7 figure

    Neuroimaging at 7 Tesla: a pictorial narrative review

    Get PDF
    Neuroimaging using the 7-Tesla (7T) human magnetic resonance (MR) system is rapidly gaining popularity after being approved for clinical use in the European Union and the USA. This trend is the same for functional MR imaging (MRI). The primary advantages of 7T over lower magnetic fields are its higher signal-to-noise and contrast-to-noise ratios, which provide high-resolution acquisitions and better contrast, making it easier to detect lesions and structural changes in brain disorders. Another advantage is the capability to measure a greater number of neurochemicals by virtue of the increased spectral resolution. Many structural and functional studies using 7T have been conducted to visualize details in the white matter and layers of the cortex and hippocampus, the subnucleus or regions of the putamen, the globus pallidus, thalamus and substantia nigra, and in small structures, such as the subthalamic nucleus, habenula, perforating arteries, and the perivascular space, that are difficult to observe at lower magnetic field strengths. The target disorders for 7T neuroimaging range from tumoral diseases to vascular, neurodegenerative, and psychiatric disorders, including Alzheimer’s disease, Parkinson’s disease, multiple sclerosis, epilepsy, major depressive disorder, and schizophrenia. MR spectroscopy has also been used for research because of its increased chemical shift that separates overlapping peaks and resolves neurochemicals more effectively at 7T than a lower magnetic field. This paper presents a narrative review of these topics and an illustrative presentation of images obtained at 7T. We expect 7T neuroimaging to provide a new imaging biomarker of various brain disorders
    corecore