60 research outputs found

    Megahertz serial crystallography

    Get PDF
    The new European X-ray Free-Electron Laser is the first X-ray free-electron laser capable of delivering X-ray pulses with a megahertz inter-pulse spacing, more than four orders of magnitude higher than previously possible. However, to date, it has been unclear whether it would indeed be possible to measure high-quality diffraction data at megahertz pulse repetition rates. Here, we show that high-quality structures can indeed be obtained using currently available operating conditions at the European XFEL. We present two complete data sets, one from the well-known model system lysozyme and the other from a so far unknown complex of a β-lactamase from K. pneumoniae involved in antibiotic resistance. This result opens up megahertz serial femtosecond crystallography (SFX) as a tool for reliable structure determination, substrate screening and the efficient measurement of the evolution and dynamics of molecular structures using megahertz repetition rate pulses available at this new class of X-ray laser source

    Features of “All LNA” Duplexes Showing a New Type of Nucleic Acid Geometry

    Get PDF
    “Locked nucleic acids” (LNAs) belong to the backbone-modified nucleic acid family. The 2′-O,4′-C-methylene-β-D-ribofuranose nucleotides are used for single or multiple substitutions in RNA molecules and thereby introduce enhanced bio- and thermostability. This renders LNAs powerful tools for diagnostic and therapeutic applications. RNA molecules maintain the overall canonical A-type conformation upon substitution of single or multiple residues/nucleotides by LNA monomers. The structures of “all” LNA homoduplexes, however, exhibit significant differences in their overall geometry, in particular a decreased twist, roll and propeller twist. This results in a widening of the major groove, a decrease in helical winding, and an enlarged helical pitch. Therefore, the LNA duplex structure can no longer be described as a canonical A-type RNA geometry but can rather be brought into proximity to other backbone-modified nucleic acids, like glycol nucleic acids or peptide nucleic acids. LNA-modified nucleic acids provide thus structural and functional features that may be successfully exploited for future application in biotechnology and drug discovery

    Femtosecond x-ray diffraction from an aerosolized beam of protein nanocrystals

    Get PDF
    We demonstrate near-atomic-resolution Bragg diffraction from aerosolized single granulovirus crystals using an x-ray free-electron laser. The form of the aerosol injector is nearly identical to conventional liquid-microjet nozzles, but the x-ray-scattering background is reduced by several orders of magnitude by the use of helium carrier gas rather than liquid. This approach provides a route to study the weak diffuse or lattice-transform signal arising from small crystals. The high speed of the particles is particularly well suited to upcoming MHz-repetition-rate x-ray free-electron lasers

    Rapid sample delivery for megahertz serial crystallography at X-ray FELs

    Get PDF
    Liquid microjets are a common means of delivering protein crystals to the focus of X-ray free-electron lasers (FELs) for serial femtosecond crystallography measurements. The high X-ray intensity in the focus initiates an explosion of the microjet and sample. With the advent of X-ray FELs with megahertz rates, the typical velocities of these jets must be increased significantly in order to replenish the damaged material in time for the subsequent measurement with the next X-ray pulse. This work reports the results of a megahertz serial diffraction experiment at the FLASH FEL facility using 4.3 nm radiation. The operation of gas-dynamic nozzles that produce liquid microjets with velocities greater than 80 m s-1 was demonstrated. Furthermore, this article provides optical images of X-ray-induced explosions together with Bragg diffraction from protein microcrystals exposed to trains of X-ray pulses repeating at rates of up to 4.5 MHz. The results indicate the feasibility for megahertz serial crystallography measurements with hard X-rays and give guidance for the design of such experiments

    Segmented flow generator for serial crystallography at the European X-ray free electron laser

    Get PDF
    Serial femtosecond crystallography (SFX) with X-ray free electron lasers (XFELs) allows structure determination of membrane proteins and time-resolved crystallography. Common liquid sample delivery continuously jets the protein crystal suspension into the path of the XFEL, wasting a vast amount of sample due to the pulsed nature of all current XFEL sources. The European XFEL (EuXFEL) delivers femtosecond (fs) X-ray pulses in trains spaced 100 ms apart whereas pulses within trains are currently separated by 889 ns. Therefore, continuous sample delivery via fast jets wastes >99% of sample. Here, we introduce a microfluidic device delivering crystal laden droplets segmented with an immiscible oil reducing sample waste and demonstrate droplet injection at the EuXFEL compatible with high pressure liquid delivery of an SFX experiment. While achieving ~60% reduction in sample waste, we determine the structure of the enzyme 3-deoxy-D-manno-octulosonate-8-phosphate synthase from microcrystals delivered in droplets revealing distinct structural features not previously reported

    Electrically stimulated droplet injector for reduced sample consumption in serial crystallography

    Get PDF
    15 pags., 6 figs., 1 tab.With advances in X-ray free-electron lasers (XFELs), serial femtosecond crystallography (SFX) has enabled the static and dynamic structure determination for challenging proteins such as membrane protein complexes. In SFX with XFELs, the crystals are typically destroyed after interacting with a single XFEL pulse. Therefore, thousands of new crystals must be sequentially introduced into the X-ray beam to collect full data sets. Because of the serial nature of any SFX experiment, up to 99% of the sample delivered to the X-ray beam during its "off-time" between X-ray pulses is wasted due to the intrinsic pulsed nature of all current XFELs. To solve this major problem of large and often limiting sample consumption, we report on improvements of a revolutionary sample-saving method that is compatible with all current XFELs. We previously reported 3D-printed injection devices coupled with gas dynamic virtual nozzles (GDVNs) capable of generating samples containing droplets segmented by an immiscible oil phase for jetting crystal-laden droplets into the path of an XFEL. Here, we have further improved the device design by including metal electrodes inducing electrowetting effects for improved control over droplet generation frequency to stimulate the droplet release to matching the XFEL repetition rate by employing an electrical feedback mechanism. We report the improvements in this electrically triggered segmented flow approach for sample conservation in comparison with a continuous GDVN injection using the microcrystals of lysozyme and 3-deoxy-D-manno-octulosonate 8-phosphate synthase and report the segmented flow approach for sample injection applied at the Macromolecular Femtosecond Crystallography instrument at the Linear Coherent Light Source for the first time.Financial support from the STC Program of the National Science Foundation through BioXFEL under agreement no. 1231306, NSF ABI Innovations award no. 1565180, and the National Institutes of Health award no. R01GM095583 is gratefully acknowledged. The use of the Linac Coherent Light Source (LCLS), SLAC National Accelerator Laboratory, is generously supported by the US Department of Energy, Office of Science, Office of Basic Energy Sciences under contract no. DE-AC02-76SF00515. The HERA system for in-helium experiments at MFX was developed by Bruce Doak and funded by the Max Planck Institute for Medical Research. This work was also supported by The Center for Structural Dynamics in Biology, NIH grant P41GM139687.Peer reviewe

    Biological single-particle imaging using XFELs – towards the next resolution revolution

    No full text
    The development of X-ray free-electron lasers (XFELs) has opened the possibility to investigate the ultrafast dynamics of biomacromolecules using X-ray diffraction. Whereas an increasing number of structures solved by means of serial femtosecond crystallography at XFELs is available, the effect of radiation damage on protein crystals during ultrafast exposures has remained an open question. We used a split-and-delay line based on diffractive X-ray optics at the Linac Coherent Light Source XFEL to investigate the time dependence of X-ray radiation damage to lysozyme crystals. For these tests, crystals were delivered to the X-ray beam using a fixed-target approach. The presented experiments provide probe signals at eight different delay times between 19 and 213 femtoseconds after a single pump event, thereby covering the time-scales relevant for femtosecond serial crystallography. Even though significant impact on the crystals was observed at long time scales after exposure with a single X-ray pulse, the collected diffraction data did not show significant signal reduction that could be assigned to beam damage on the crystals in the sampled time window and resolution range. This observation is in agreement with estimations of the applied radiation dose, which in our experiment was clearly below the values expected to cause damage on the femtosecond time scale. The experiments presented here demonstrate the feasibility of time-resolved pump-multiprobe X-ray diffraction experiments on protein crystals

    From XFELs to Synchrotrons and back: High output serial crystallography to image the structure and dynamics of biological macromolecules

    No full text
    The establishment of serial methods in macromolecular crystallography since the seminal experiments by Chapman et al. at LCLS in 2008 led, together with the re-discovery of crystallography under ambient conditions to a re-emergence of time-resolved studies to track the dynamic properties of functioning proteins. It also enabled structure determination using sub-micron sized crystals and - using an XFEL - circumvents many challenges related to radiation damage. Initially many critics doubted that serial crystallography would work, but from experimental phasing to superior difference maps from time-resolved experiments, the critics could be proven wrong every single time. Today it is a robust method, thanks also to strong developments in sample delivery procedures and data processing algorithms. One challenge still remains, however: the availability of beamtime and access for novice user groups, even with five XFELs in operation. It is therefore necessary to strongly consider for which scientific question an XFEL is needed, what could be done by serial crystallography at synchrotron light sources (SSX), where experiments at both XFELs and Synchrotrons would complement each other and how such decisions can be made in a way that benefits science and at the same time lowers the access barriers for users. To address these issues, results from recent experiments at both the European XFEL and PETRAIII will be shown here, ranging from new protein structures using native nano-crystals and de novo structure determination through a combination of nanoSFX and Alphafold2, to approaches to data collection under (almost) physiological conditions

    Raw diffraction data (CBF) for a structure of SARS-CoV-2 Main Protease bound to 2-Methyl-1-tetralone

    No full text
    Data collected at beamline P11/PETRAIII Deutsches Elektronen Synchrotron DESY. Co-crystallization of Sars-CoV-2 MPro with the compound was achieved by equlibrating a 6.25 mg/ml protein solution in 20 mM HEPES buffer (pH 7.8) containing 1 mM DTT, 1mM EDTA, and 150 mM NaCl against a reservoir solution of 100 mM MIB buffer (2:3:3 molar ratio of malonic acid, imidazole, and boric acid), pH 7.5, containing 25% v/v PEG 1500 and 5% v/v DMSO. Prior to crystallization compound solutions in DMSO were dried onto the wells of SwissCI 96-well plates. To achieve reproducible crystal growth seeding was used. Crystals appeared within a few hours and reached their final size after 2 -3 days. Crystals were manually harvested and flash cooled in liquid nitrogen for subsequent X-ray diffraction data collection

    JINXED: Just in time crystallization for easy structure determination of biological macromolecules

    No full text
    Macromolecular crystallography is a well-established method in the field of structure biology and has led to the majority of known protein structures to date. After focusing on static structures, the method is now developing towards the investigation of protein dynamics through time-resolved methods. These experiments often require multiple handling steps of the sensitive protein crystals, e.g. for ligand soaking and cryo-protection. These handling steps can cause significant crystal damage, causing a decrease in data quality. Furthermore, in time-resolved experiments based on serial crystallography that use micron-sized crystals for short diffusion times of ligands, certain crystal morphologies with small solvent channels can prevent sufficient ligand diffusion. Described here is a method combining protein crystallization and data collection in a novel one-step-process. Corresponding experiments were successfully performed as a proof-of-principle using hen egg white lysozyme and crystallization times of only a few seconds. This method called JINXED (Just in time crystallization for easy structure determination) promises to result in high-quality data due the avoidance of crystal handling and has the potential to enable time-resolved experiments with crystals containing small solvent channels by adding potential ligands to the crystallization buffer, simulating traditional co-crystallization approaches
    corecore