108 research outputs found

    Virus-like particle distribution and abundance in sediments and overlying waters along eutrophication gradients in two subtropical estuaries

    Get PDF
    Viruses are recognized as ubiquitous components of marine ecosystems; however, there has been limited study of viral abundance and its ecological role in sediments. Viral abundance was determined in both the water column and sediments of a eutrophic (Brisbane River/Moreton Bay; 27°25′S, 153°5′E) and oligotrophic (Noosa River; 26°15′S, 153°0′E) estuary in subtropical Queensland, Australia. Viruses, bacteria, and microalgae from both water column and extracted sediment samples were enumerated using SYBR Green I staining and epifluorescence microscopy. Sediment viral abundance ranged from 10 to 10 particles cm of sediment, bacterial abundance ranged from 10 to 10 cells cm of sediment, and microalgal abundance ranged from 10 to 10 cells cm sediment. Pelagic abundances for all microorganisms were 10-1,000-fold lower than sediment abundances. Correlations between viral abundances and suspended solids suggest that viruses sorbed to suspended material in the water column may settle out and contribute to the benthic viral population. Virus production was measured by a time course increase of viral abundance in seawater using a dilution technique. Virus production was highest in eutrophic waters of the Brisbane River, and addition of inorganic nutrients (NO + NH + PO + SiO) stimulated viral production rates at all stations by 14-52% above ambient, suggesting that inorganic nutrient availability may play a key role in aquatic viral abundance

    Validation of a new method for building a three-dimensional physical model of the skull and dentition

    No full text
    We present a new method for replicating the skull and occlusal surface with an accurate physical model that could be used for planning orthognathic surgery. The investigation was made on 6 human skulls, and a polyvinyl splint was fabricated on the dental cast of the maxillary dentition in each case. A cone beam computed tomogram (CBCT) was taken of each skull and a three-dimensional replica produced. The distorted dentition (as a result of magnification errors and streak artefacts) was removed from the three-dimensional model and replaced by new plaster dentition that was fabricated using the polyvinyl splint and a transfer jig replication technique. To verify the accuracy of the method the human skulls and the three dimensional replica model, with the new plaster dentition in situ, were scanned using a laser scanner. The three-dimensional images produced were superimposed to identify the errors associated with the replacement of the distorted occlusal surface with the new plaster dentition. The overall mean error was 0.72 and SD was (0.26) mm. The accuracy of the method encouraged us to use it clinically in a case of pronounced facial asymmetry

    Low-speed longitudinal aerodynamic characteristics of a flat-plate planform model of an advanced fighter configuration

    Get PDF
    A flat-plate wind tunnel model of an advanced fighter configuration was tested in the NASA LaRC Subsonic Basic Research Tunnel and the 16- by 24-inch Water Tunnel. The test objectives were to obtain and evaluate the low-speed longitudinal aerodynamic characteristics of a candidate configuration for the integration of several new innovative wing designs. The flat plate test allowed for the initial evaluation of the candidate planform and was designated as the baseline planform for the innovative wing design study. Low-speed longitudinal aerodynamic data were obtained over a range of freestream dynamic pressures from 7.5 psf to 30 psf (M = 0.07 to M = 0.14) and angles-of-attack from 0 to 40 deg. The aerodynamic data are presented in coefficient form for the lift, induced drag, and pitching moment. Flow-visualization results obtained were photographs of the flow pattern over the flat plate model in the water tunnel for angles-of-attack from 10 to 40 deg. The force and moment coefficients and the flow-visualization photographs showed the linear and nonlinear aerodynamic characteristics due to attached flow and vortical flow over the flat plate model. Comparison between experiment and linear theory showed good agreement for the lift and induced drag; however, the agreement was poor for the pitching moment

    Genomic prediction of coronary heart disease

    Get PDF
    Aims Genetics plays an important role in coronary heart disease (CHD) but the clinical utility of genomic risk scores (GRSs) relative to clinical risk scores, such as the Framingham Risk Score (FRS), is unclear. Our aim was to construct and externally validate a CHD GRS, in terms of lifetime CHD risk and relative to traditional clinical risk scores. Methods and results We generated a GRS of 49 310 SNPs based on a CARDIoGRAMplusC4D Consortium meta-analysis of CHD, then independently tested it using five prospective population cohorts (three FINRISK cohorts, combined n = 12 676, 757 incident CHD events; two Framingham Heart Study cohorts (FHS), combined n = 3406, 587 incident CHD events). The GRS was associated with incident CHD (FINRISK HR = 1.74, 95% confidence interval (CI) 1.61-1.86 per S.D. of GRS; Framingham HR = 1.28, 95% CI 1.18-1.38), and was largely unchanged by adjustment for known risk factors, including family history. Integration of the GRS with the FRS or ACC/AHA13 scores improved the 10 years risk prediction (meta-analysis C-index: +1.5-1.6%, P = 60 years old (meta-analysis C-index: +4.6-5.1%, P <0.001). Importantly, the GRS captured substantially different trajectories of absolute risk, with men in the top 20% of attaining 10% cumulative CHD risk 12-18 y earlier than those in the bottom 20%. High genomic risk was partially compensated for by low systolic blood pressure, low cholesterol level, and non-smoking. Conclusions A GRS based on a large number of SNPs improves CHD risk prediction and encodes different trajectories of lifetime risk not captured by traditional clinical risk scores.Peer reviewe

    Meniscus-assisted solution printing of large-grained perovskite films for high-efficiency solar cells

    Get PDF
    Control over morphology and crystallinity of metal halide perovskite films is of key importance to enable high-performance optoelectronics. However, this remains particularly challenging for solution-printed devices due to the complex crystallization kinetics of semiconductor materials within dynamic flow of inks. Here we report a simple yet effective meniscus-assisted solution printing (MASP) strategy to yield large-grained dense perovskite film with good crystallization and preferred orientation. Intriguingly, the outward convective flow triggered by fast solvent evaporation at the edge of the meniscus ink imparts the transport of perovskite solutes, thus facilitating the growth of micrometre-scale perovskite grains. The growth kinetics of perovskite crystals is scrutinized by in situ optical microscopy tracking to understand the crystallization mechanism. The perovskite films produced by MASP exhibit excellent optoelectronic properties with efficiencies approaching 20% in planar perovskite solar cells. This robust MASP strategy may in principle be easily extended to craft other solution-printed perovskite-based optoelectronics

    Magnetic Resonance Thermometry at 7T for Real-Time Monitoring and Correction of Ultrasound Induced Mild Hyperthermia

    Get PDF
    While Magnetic Resonance Thermometry (MRT) has been extensively utilized for non-invasive temperature measurement, there is limited data on the use of high field (≥7T) scanners for this purpose. MR-guided Focused Ultrasound (MRgFUS) is a promising non-invasive method for localized hyperthermia and drug delivery. MRT based on the temperature sensitivity of the proton resonance frequency (PRF) has been implemented in both a tissue phantom and in vivo in a mouse Met-1 tumor model, using partial parallel imaging (PPI) to speed acquisition. An MRgFUS system capable of delivering a controlled 3D acoustic dose during real time MRT with proportional, integral, and derivative (PID) feedback control was developed and validated. Real-time MRT was validated in a tofu phantom with fluoroptic temperature measurements, and acoustic heating simulations were in good agreement with MR temperature maps. In an in vivo Met-1 mouse tumor, the real-time PID feedback control is capable of maintaining the desired temperature with high accuracy. We found that real time MR control of hyperthermia is feasible at high field, and k-space based PPI techniques may be implemented for increasing temporal resolution while maintaining temperature accuracy on the order of 1°C
    • …
    corecore