1,527 research outputs found

    Perinatal and paediatric post-mortem magnetic resonance imaging (PMMR): sequences and technique

    Get PDF
    As post-mortem MRI (PMMR) becomes more widely used for investigation following perinatal and paediatric deaths, the best possible images should be acquired. In this article, we review the most widely used published PMMR sequences, together with outlining our acquisition protocol and sequence parameters for foetal, perinatal and paediatric PMMR. We give examples of both normal and abnormal appearances, so that the reader can understand the logic behind each acquisition step before interpretation, as a useful day-to-day reference guide to performing PMMR

    Signalling Responses Following Varying Sequencing of Strength and Endurance Training in a Fed State.

    Get PDF
    The objective of this study was to compare anabolic signalling responses to differing sequences of concurrent strength and endurance training in a fed state.Eighteen resistance-trained males were randomly assigned to the following experimental conditions; i) strength training (ST), ii) strength followed by endurance training (ST-END) or iii) endurance followed by strength training (END-ST). Muscle tissue samples were taken from the vastus lateralis before each exercise protocol, upon cessation of exercise, and 1 h-post cessation of strength training. Tissue was analysed for total and phosphorylated (p-) signalling proteins linked to the mTOR and AMPK networks.Strength training performance was similar between ST, ST-END and END-ST. p-S6k1 was elevated from baseline 1 h post training in ST and ST-END (both p < 0.05). p-4E-BP1 was significantly lower than baseline post ST (p = 0.01), while 1 h post exercise in the ST-END condition p-4E-BP1 was significantly greater than post exercise (p = 0.04). p-ACC was elevated from baseline both post and 1 h post exercise (both p < 0.05) in the END-ST condition. AMPK, mTOR, p38, PKB, eEF2 responded similarly to the ST, ST-END and END-ST. Signalling responses to ST, ST-END and END were largely similar. As such it cannot be ascertained which sequence of concurrent strength and endurance training is most favourable in promoting anabolic signalling.These data indicate that in the case of the present study an acute bout of concurrent training of differing sequences elicited similar responses of the AMPK and mTOR networks

    Application of the speed-duration relationship to normalize the intensity of high-intensity interval training

    Get PDF
    The tolerable duration of continuous high-intensity exercise is determined by the hyperbolic Speed-tolerable duration (S-tLIM) relationship. However, application of the S-tLIM relationship to normalize the intensity of High-Intensity Interval Training (HIIT) has yet to be considered, with this the aim of present study. Subjects completed a ramp-incremental test, and series of 4 constant-speed tests to determine the S-tLIM relationship. A sub-group of subjects (n = 8) then repeated 4 min bouts of exercise at the speeds predicted to induce intolerance at 4 min (WR4), 6 min (WR6) and 8 min (WR8), interspersed with bouts of 4 min recovery, to the point of exercise intolerance (fixed WR HIIT) on different days, with the aim of establishing the work rate that could be sustained for 960 s (i.e. 4Γ—4 min). A sub-group of subjects (n = 6) also completed 4 bouts of exercise interspersed with 4 min recovery, with each bout continued to the point of exercise intolerance (maximal HIIT) to determine the appropriate protocol for maximizing the amount of high-intensity work that can be completed during 4Γ—4 min HIIT. For fixed WR HIIT tLIM of HIIT sessions was 399Β±81 s for WR4, 892Β±181 s for WR6 and 1517Β±346 s for WR8, with total exercise durations all significantly different from each other (P&#60;0.050). For maximal HIIT, there was no difference in tLIM of each of the 4 bouts (Bout 1: 229Β±27 s; Bout 2: 262Β±37 s; Bout 3: 235Β±49 s; Bout 4: 235Β±53 s; P&#62;0.050). However, there was significantly less high-intensity work completed during bouts 2 (153.5Β±40. 9 m), 3 (136.9Β±38.9 m), and 4 (136.7Β±39.3 m), compared with bout 1 (264.9Β±58.7 m; P&#62;0.050). These data establish that WR6 provides the appropriate work rate to normalize the intensity of HIIT between subjects. Maximal HIIT provides a protocol which allows the relative contribution of the work rate profile to physiological adaptations to be considered during alternative intensity-matched HIIT protocols

    Development and validation of a physical model to investigate the biomechanics of infant head impact

    Get PDF
    Head injury in childhood is the single most common cause of death or permanent disability from injury. However, despite its frequency and significance, there is little understanding of the response of a child's head to injurious loading. This is a significant limitation when making early diagnoses, informing clinical and/or forensic management or injury prevention strategies. With respect to impact vulnerability, current understanding is predominantly based on a few post-mortem-human-surrogate (PMHS) experiments. Researchers, out of experimental necessity, typically derive acceleration data, currently an established measure for head impact vulnerability, by calculation. Impact force is divided by the head mass, to produce a "global approximation", a single-generalised head response acceleration value. A need exists for a new experimental methodology, which can provide specific regional or localised response data. A surrogate infant head, was created from high resolution computer tomography scans with properties closely matched to tissue response data and validated against PMHS head impact acceleration data. The skull was 3D-printed from co-polymer materials. The brain, represented as a lumped mass, comprised of an injected gelatin/water mix. High-Speed Digital-Image-Correlation optically measured linear and angular velocities and accelerations, strains and strain rates. The "global approximation" was challenged by comparison with regional and local acceleration data. During impacts, perpendicular (at 90Β°) to a surface, regional and local accelerations were up to three times greater than the concomitant "global" accelerations. Differential acceleration patterns were very sensitive to impact location. Suture and fontanelle regions demonstrated ten times more strain (103%/s) than bone, resulting in skull deformations similar in magnitude to those observed during child birth, but at much higher rates. Surprisingly, perpendicular impacts produced significantly greater rotational velocities and accelerations, which are closer to current published injury thresholds than expected, seemingly as a result of deformational changes to the complex skull geometry. The methodology has proven a significant new step in characterising and understanding infant head injury mechanics

    Detection of involved margins in breast specimens with x-ray phase-contrast computed tomography

    Get PDF
    Margins of wide local excisions in breast conserving surgery are tested through histology, which can delay results by days and lead to second operations. Detection of margin involvement intraoperatively would allow the removal of additional tissue during the same intervention. X-ray phase contrast imaging (XPCI) provides soft tissue sensitivity superior to conventional X-rays: we propose its use to detect margin involvement intraoperatively. We have developed a system that can perform phase-based computed tomography (CT) scans in minutes, used it to image 101 specimens approximately half of which contained neoplastic lesions, and compared results against those of a commercial system. Histological analysis was carried out on all specimens and used as the gold standard. XPCI-CT showed higher sensitivity (83%, 95% CI 69–92%) than conventional specimen imaging (32%, 95% CI 20–49%) for detection of lesions at margin, and comparable specificity (83%, 95% CI 70–92% vs 86%, 95% CI 73–93%). Within the limits of this study, in particular that specimens obtained from surplus tissue typically contain small lesions which makes detection more difficult for both methods, we believe it likely that the observed increase in sensitivity will lead to a comparable reduction in the number of re-operations

    Detection of involved margins in breast specimens with X-ray phase-contrast computed tomography.

    Get PDF
    Margins of wide local excisions in breast conserving surgery are tested through histology, which can delay results by days and lead to second operations. Detection of margin involvement intraoperatively would allow the removal of additional tissue during the same intervention. X-ray phase contrast imaging (XPCI) provides soft tissue sensitivity superior to conventional X-rays: we propose its use to detect margin involvement intraoperatively. We have developed a system that can perform phase-based computed tomography (CT) scans in minutes, used it to image 101 specimens approximately half of which contained neoplastic lesions, and compared results against those of a commercial system. Histological analysis was carried out on all specimens and used as the gold standard. XPCI-CT showed higher sensitivity (83%, 95% CI 69-92%) than conventional specimen imaging (32%, 95% CI 20-49%) for detection of lesions at margin, and comparable specificity (83%, 95% CI 70-92% vs 86%, 95% CI 73-93%). Within the limits of this study, in particular that specimens obtained from surplus tissue typically contain small lesions which makes detection more difficult for both methods, we believe it likely that the observed increase in sensitivity will lead to a comparable reduction in the number of re-operations

    Volumetric high-resolution X-ray phase-contrast virtual histology of breast specimens with a compact laboratory system

    Get PDF
    The assessment of margin involvement is a fundamental task in breast conserving surgery to prevent recurrences and reoperations. It is usually performed through histology, which makes the process time consuming and can prevent the complete volumetric analysis of large specimens. X-ray phase contrast tomography combines high resolution, sufficient penetration depth and high soft tissue contrast, and can therefore provide a potential solution to this problem. In this work, we used a high-resolution implementation of the edge illumination X-ray phase contrast tomography based on "pixel-skipping" X-ray masks and sample dithering, to provide high definition virtual slices of breast specimens. The scanner was originally designed for intra-operative applications in which short scanning times were prioritised over spatial resolution; however, thanks to the versatility of edge illumination, high-resolution capabilities can be obtained with the same system simply by swapping x-ray masks without this imposing a reduction in the available field of view. This makes possible an improved visibility of fine tissue strands, enabling a direct comparison of selected CT slices with histology, and providing a tool to identify suspect features in large specimens before slicing. Combined with our previous results on fast specimen scanning, this works paves the way for the design of a multi-resolution EI scanner providing intra-operative capabilities as well as serving as a digital pathology system
    • …
    corecore