2,375 research outputs found

    Differential metabolic and biological profiles of Lychnophora ericoides mart. (Asteraceae) from different localities in the Brazilian "campos rupestres"

    Full text link
    This paper reports HPLC-DAD-MS/MS and HPLC-ECD characterisation of secondary metabolite profiles of Lychnophora ericoides Mart. leaf extracts from different provenances and their cytotoxic and antioxidant properties. Leaf extracts from populations representing seven different locations were evaluated for antioxidant activity by the DPPH radical scavenging system and activity towards cellular growth in three tumor cell lines. The extracts were electrochemically analysed by HPLC-ECD and their main secondary metabolites were identified by HPLC-DAD-MS and HPLC-DAD-MS/MS. An amplified defensive secondary chemistry, together with maximal cytotoxic and antioxidant bioactivities, were found for plants collected at the interface between two types of forest. These findings furnish additional support for the hypothesis that plants occurring at the interface between two forests ecosystems might be stimulated to amplify their own production and storage of defensive secondary metabolites due to the greater number of environmental influences

    Diagnostic accuracy of five serologic tests for Strongyloides stercoralis infection.

    Get PDF
    Background: The diagnosis of Strongyloides stercoralis (S. stercoralis) infection is hampered by the suboptimal sensitivity of fecal-based tests. Serological methods are believed to be more sensitive, although assessing their accuracy is difficult because of the lack of sensitivity of a fecal-based reference ('gold') standard. Methods: The sensitivity and specificity of 5 serologic tests for S. stercoralis (in-house IFAT, NIE-ELISA and NIE-LIPS and the commercially available Bordier-ELISA and IVD-ELISA) were assessed on 399 cryopreserved serum samples. Accuracy was measured using fecal results as the primary reference standard, but also using a composite reference standard (based on a combination of tests). Results: According to the latter standard, the most sensitive test was IFAT, with 94.6% sensitivity (91.2-96.9), followed by IVD-ELISA (92.3%, 87.7-96.9). The most specific test was NIE-LIPS, with specificity 99.6% (98.9-100), followed by IVD-ELISA (97.4%, 95.5-99.3). NIE-LIPS did not cross-react with any of the specimens from subjects with other parasitic infections. NIE-LIPS and the two commercial ELISAs approach 100% specificity at a cut off level that maintains ≥70% sensitivity. Conclusions: NIE-LIPS is the most accurate serologic test for the diagnosis of S. stercoralis infection. IFAT and each of the ELISA tests are sufficiently accurate, above a given cut off, for diagnosis, prevalence studies and inclusion in clinical trials

    The Fast Read-out System for the MAPMTs of COMPASS RICH-1

    Full text link
    A fast readout system for the upgrade of the COMPASS RICH detector has been developed and successfully used for data taking in 2006 and 2007. The new readout system for the multi-anode PMTs in the central part of the photon detector of the RICH is based on the high-sensitivity MAD4 preamplifier-discriminator and the dead-time free F1-TDC chip characterized by high-resolution. The readout electronics has been designed taking into account the high photon flux in the central part of the detector and the requirement to run at high trigger rates of up to 100 kHz with negligible dead-time. The system is designed as a very compact setup and is mounted directly behind the multi-anode photomultipliers. The data are digitized on the frontend boards and transferred via optical links to the readout system. The read-out electronics system is described in detail together with its measured performances.Comment: Proceeding of RICH2007 Conference, Trieste, Oct. 2007. v2: minor change

    Fast Photon Detection for Particle Identification with COMPASS RICH-1

    Get PDF
    Particle identification at high rates is an important challenge for many current and future high-energy physics experiments. The upgrade of the COMPASS RICH-1 detector requires a new technique for Cherenkov photon detection at count rates of several 10610^6 per channel in the central detector region, and a read-out system allowing for trigger rates of up to 100 kHz. To cope with these requirements, the photon detectors in the central region have been replaced with the detection system described in this paper. In the peripheral regions, the existing multi-wire proportional chambers with CsI photocathode are now read out via a new system employing APV pre-amplifiers and flash ADC chips. The new detection system consists of multi-anode photomultiplier tubes (MAPMT) and fast read-out electronics based on the MAD4 discriminator and the F1-TDC chip. The RICH-1 is in operation in its upgraded version for the 2006 CERN SPS run. We present the photon detection design, constructive aspects and the first Cherenkov light in the detector.Comment: Proceedings of the Imaging 2006 conference, Stockholm, Sweden, 27-30 June 2006, 5 pages, 6 figures, to appear in NIM A; corrected typo in caption of Fig.

    Fast photon detection for the COMPASS RICH detector

    Get PDF
    The COMPASS experiment at the SPS accelerator at CERN uses a large scale Ring Imaging CHerenkov detector (RICH) to identify pions, kaons and protons in a wide momentum range. For the data taking in 2006, the COMPASS RICH has been upgraded in the central photon detection area (25% of the surface) with a new technology to detect Cherenkov photons at very high count rates of several 10^6 per second and channel and a new dead-time free read-out system, which allows trigger rates up to 100 kHz. The Cherenkov photons are detected by an array of 576 visible and ultra-violet sensitive multi-anode photomultipliers with 16 channels each. The upgraded detector showed an excellent performance during the 2006 data taking.Comment: Proceeding of the IPRD06 conference (Siena, Okt. 06

    Measurement of the Longitudinal Spin Transfer to Lambda and Anti-Lambda Hyperons in Polarised Muon DIS

    Get PDF
    The longitudinal polarisation transfer from muons to lambda and anti-lambda hyperons, D_LL, has been studied in deep inelastic scattering off an unpolarised isoscalar target at the COMPASS experiment at CERN. The spin transfers to lambda and anti-lambda produced in the current fragmentation region exhibit different behaviours as a function of x and xF . The measured x and xF dependences of D^lambda_LL are compatible with zero, while D^anti-lambda_LL tends to increase with xF, reaching values of 0.4 - 0.5. The resulting average values are D^lambda_LL = -0.012 +- 0.047 +- 0.024 and D^anti-lambda_LL = 0.249 +- 0.056 +- 0.049. These results are discussed in the frame of recent model calculations.Comment: 13 pages, 7 figure

    First Measurement of Chiral Dynamics in \pi^- \gamma -> \pi^- \pi^- \pi^+

    Full text link
    The COMPASS collaboration at CERN has investigated the \pi^- \gamma -> \pi^- \pi^- \pi^+ reaction at center-of-momentum energy below five pion masses, sqrt(s) < 5 m(\pi), embedded in the Primakoff reaction of 190 GeV pions impinging on a lead target. Exchange of quasi-real photons is selected by isolating the sharp Coulomb peak observed at smallest momentum transfers, t' < 0.001 (GeV/c)^2. Using partial-wave analysis techniques, the scattering intensity of Coulomb production described in terms of chiral dynamics and its dependence on the 3\pi-invariant mass m(3\pi) = sqrt(s) were extracted. The absolute cross section was determined in seven bins of s\sqrt{s} with an overall precision of 20%. At leading order, the result is found to be in good agreement with the prediction of chiral perturbation theory over the whole energy range investigated.Comment: 10 pages, 5 figure

    The Polarised Valence Quark Distribution from semi-inclusive DIS

    Get PDF
    The semi-inclusive difference asymmetry A^{h^{+}-h^{-}} for hadrons of opposite charge has been measured by the COMPASS experiment at CERN. The data were collected in the years 2002-2004 using a 160 GeV polarised muon beam scattered off a large polarised ^6LiD target and cover the range 0.006 < x < 0.7 and 1 < Q^2 < 100 (GeV/c)^2. In leading order QCD (LO) the asymmetry A_d^{h^{+}-h^{-}} measures the valence quark polarisation and provides an evaluation of the first moment of Delta u_v + Delta d_v which is found to be equal to 0.40 +- 0.07 (stat.) +- 0.05 (syst.) over the measured range of x at Q^2 = 10 (GeV/c)^2. When combined with the first moment of g_1^d previously measured on the same data, this result favours a non-symmetric polarisation of light quarks Delta u-bar = - Delta d-bar at a confidence level of two standard deviations, in contrast to the often assumed symmetric scenario Delta u-bar = Delta d-bar = Delta s-bar = Delta s.Comment: 7 pages, 3 figures, COMPASS, revised: details added, author list update

    Manejo de solo para implantação de adubos verdes em sistemas agroflorestais agroecológicos.

    Get PDF
    Resumo: A adubação verde consiste no emprego de plantas anuais capazes de garantir melhores condições de ciclagem de nutrientes ao agroecossistema por meio da incorporação da sua biomassa ao solo. O objetivo deste trabalho foi monitorar e avaliar o desenvolvimento das plantas consorciadas submetidas a dois diferentes preparos de solo, um com preparo mais intensivo do solo em que se utilizou a grade aradora e o outro com um preparo menos intensivo em que foi utilizada a enxada rotativa. Foi encontrado melhor desenvolvimento das espécies de nabo forrageiro e girassol no preparo de solo mais intensivo e melhor desenvolvimento e número de espécies de aveia preta no preparo menos intensivo. Conclui-se a importância do preparo de solo para desenvolvimento das plantas e do aprofundamento de pesquisas para adubação verde em sistemas agroflorestais agroecológicos
    corecore