36 research outputs found

    Comparison of Glasgow Admission Prediction Score and Amb Score in predicting need for inpatient care.

    Get PDF
    AIM: We compared the abilities of two established clinical scores to predict emergency department (ED) disposition: the Glasgow Admission Prediction Score (GAPS) and the Ambulatory Score (Ambs). METHODS: The scores were compared in a prospective, multicentre cohort study. We recruited consecutive patients attending ED triage at two UK sites: Northern General Hospital in Sheffield and Glasgow Royal Infirmary, between February and May 2016. Each had a GAPS and Ambs calculated at the time of triage, with the triage nurses and treating clinicians blinded to the scores. Patients were followed up to hospital discharge. The ability of the scores to discriminate discharge from ED and from hospital at 12 and 48 hours after arrival was compared using the area under the curve (AUC) of their receiving-operator characteristics (ROC). RESULTS: 1424 triage attendances were suitable for analysis during the study period, of which 567 (39.8%) were admitted. The AUC for predicting admission was significantly higher for GAPS at 0.807 (95% CI 0.785 to 0.830), compared with 0.743 (95% CI 0.717 to 0.769) for Ambs, P12 hour and >48 hour. GAPS was also more accurate as a binary test, correctly predicting 1057 outcomes compared with 1004 for Ambs (74.2vs70.5%, P=0.012). CONCLUSION: The GAPS is a significantly better predictor of need for hospital admission than Ambs in an unselected ED population

    Multicentre, prospective observational study of the correlation between the Glasgow Admission Prediction Score and adverse outcomes

    Get PDF
    Objectives: To assess whether the Glasgow Admission Prediction Score (GAPS) is correlated with hospital length of stay, 6-month hospital readmission and 6-month all-cause mortality. This study represents a 6-month follow-up of patients who were included in an external validation of the GAPS’ ability to predict admission at the point of triage. Setting: Sampling was conducted between February and May 2016 at two separate emergency departments (EDs) in Sheffield and Glasgow. Participants: Data were collected prospectively at triage for consecutive adult patients who presented to the ED within sampling times. Any patients who avoided formal triage were excluded from the study. In total, 1420 patients were recruited. Primary outcomes: GAPS was calculated following triage and did not influence patient management. Length of hospital stay, hospital readmission and mortality against GAPS were modelled using survival analysis at 6 months. Results: Of the 1420 patients recruited, 39.6% of these patients were initially admitted to hospital. At 6 months, 30.6% of patients had been readmitted and 5.6% of patients had died. For those admitted at first presentation, the chance of being discharged fell by 4.3% (95% CI 3.2% to 5.3%) per GAPS point increase. Cox regression indicated a 9.2% (95% CI 7.3% to 11.1%) increase in the chance of 6-month hospital readmission per point increase in GAPS. An association between GAPS and 6-month mortality was demonstrated, with a hazard increase of 9.0% (95% CI 6.9% to 11.2%) for every point increase in GAPS. Conclusion: A higher GAPS is associated with increased hospital length of stay, 6-month hospital readmission and 6-month all-cause mortality. While GAPS’s primary application may be to predict admission and support clinical decision making, GAPS may provide valuable insight into inpatient resource allocation and bed planning

    Irish cardiac society - Proceedings of annual general meeting held 20th & 21st November 1992 in Dublin Castle

    Get PDF

    Measurement of the νe and total 8B solar neutrino fluxes with the Sudbury Neutrino Observatory phase-III data set

    Get PDF
    This paper details the solar neutrino analysis of the 385.17-day phase-III data set acquired by the Sudbury Neutrino Observatory (SNO). An array of 3He proportional counters was installed in the heavy-water target to measure precisely the rate of neutrino-deuteron neutral-current interactions. This technique to determine the total active 8B solar neutrino flux was largely independent of the methods employed in previous phases. The total flux of active neutrinos was measured to be 5.54-0.31+0.33(stat.)-0.34+0.36(syst.)×106 cm-2 s-1, consistent with previous measurements and standard solar models. A global analysis of solar and reactor neutrino mixing parameters yielded the best-fit values of Δm2=7.59-0.21+0.19×10 -5eV2 and θ=34.4-1.2+1.3degrees

    Scintillator ageing of the T2K near detectors from 2010 to 2021

    Get PDF
    The T2K experiment widely uses plastic scintillator as a target for neutrino interactions and an active medium for the measurement of charged particles produced in neutrino interactions at its near detector complex. Over 10 years of operation the measured light yield recorded by the scintillator based subsystems has been observed to degrade by 0.9–2.2% per year. Extrapolation of the degradation rate through to 2040 indicates the recorded light yield should remain above the lower threshold used by the current reconstruction algorithms for all subsystems. This will allow the near detectors to continue contributing to important physics measurements during the T2K-II and Hyper-Kamiokande eras. Additionally, work to disentangle the degradation of the plastic scintillator and wavelength shifting fibres shows that the reduction in light yield can be attributed to the ageing of the plastic scintillator. The long component of the attenuation length of the wavelength shifting fibres was observed to degrade by 1.3–5.4% per year, while the short component of the attenuation length did not show any conclusive degradation

    Long-Baseline Neutrino Facility (LBNF) and Deep Underground Neutrino Experiment (DUNE) Conceptual Design Report Volume 2: The Physics Program for DUNE at LBNF

    Get PDF
    The Physics Program for the Deep Underground Neutrino Experiment (DUNE) at the Fermilab Long-Baseline Neutrino Facility (LBNF) is described

    Rectus femoris surface myoelectric signal cross-talk during static contractions

    Get PDF
    The clinical application of EMG requires that the recorded signal is representative of the muscle of interest and is not contaminated with signals from adjacent muscles. Some authors report that surface EMG is not suitable for obtaining information on a single muscle but rather reflects muscle group function [J. Perry, C.S. Easterday, D.J. Antonelli, Surface versus intramuscular electrodes for electromyography of superficial and deep muscles. Physical Therapy 61 (1981) 7–15]. Other authors report however, that surface EMG is adequate to determine individual muscle function, once guidelines pertaining to data acquisition are followed [D.A. Winter, A.J. Fuglevand, S.E. Archer. Cross-talk in surface electromyography: theoretical and practical estimates. Journal of Electromyography and Kinesiology 4 (1994) 15–26]. The aim of this study was to determine whether surface EMG was suitable for monitoring rectus femoris (RF) activity during static contractions. Five healthy subjects, having given written informed consent, participated in this trial. Surface and fine wire EMG from the rectus femoris and the vastus lateralis (VL) muscles were recorded simultaneously during a protocol of static contractions consisting of knee extensions and hip flexions. Ratios were used to quantify the relationship between the surface EMG amplitude value and the fine wire EMG amplitude value for the same contraction. The results showed that hip flexion contractions elicited RF activation only and that knee extension contractions elicited fine wire activity in VL only. When the relationship between RF surface and RF fine wire electrodes was compared for hip flexion and knee extension contractions, it was observed that for all subjects, there was a tendency for increased RF surface activity in the absence of RF fine wire activity during knee extensions. It was concluded that the activity recorded by the RF surface electrode arrangement during knee extension consisted of EMG from the vastii, i.e., cross-talk and that vastus intermedius was the most likely origin of the erroneous signal. Therefore it is concluded that for accurate EMG information from RF, fine wire electrodes are necessary during a range of static contractions
    corecore