33 research outputs found

    CD81 (Cluster of Differentiation 81)

    Get PDF
    Cluster of differentiation (CD81) is a type of protein, which is encoded by CD81 gene. Beside that CD81 is also known under other names such as Target of the Antiproliferative Antibody 1 (TAPA-1) and Tetraspanin-28 (TSPAN28). Location of CD81 is known to be on chromosome 11 (11p15.5), where it contains 15-20 bases in length. It is expressed mostly in cells of testis, ovary, endometrium, placenta, bone marrow, smooth muscles and others. The main function of the CD81 protein is to mediate signal transduction events, which are important for cells' development, activation, growth and motility. The CD81 gene is also known as a candidate for many malignancies because of its location. The characteristic feature of CD81 is that it is highly hydrophobic and contains a short N- and C-terminal cytoplasmic domains together with cytoplasmic cysteines, potential sites of palmitoylation as well as four transmembrane domains where they together hold the protein in a cell membrane. There are two CD81 isoforms, isoform 1 and isoform 2. Isoforms of CD81 are usually found in a tumor-suppressor region where they have a great impact on tumor development. There has always been a high interest in research on CD81 function in viral disease development. In fact, it is known that CD81 contributes in the development of diseases such as hepatitis C, malaria and various types of cancer. Since the complete effect of CD81 is unknown, further research and scientific methodology could potentially discover all possible functions and mechanisms regulated by the CD81 protein in human body

    CDK2 (cyclin dependent kinase 2)

    Get PDF
    Review on CDK2, with data on DNA, on the protein encoded, and where the gene is implicated

    SYK (spleen tyrosine kinase)

    Get PDF

    TNFRSF9 (TNF receptor superfamily member 9)

    Get PDF
    Review on TNFRSF9 (CD137), with data on DNA, on the protein encoded, and where the gene is implicated

    PIP5K1A (phosphatidylinositol-4-phosphate 5-kinase type 1 alpha)

    Get PDF
    Review on PIP5K1A, with data on DNA, on the protein encoded, and where the gene is implicated

    PTPN9 (protein tyrosine phosphatase, non-receptor type 9)

    Get PDF
    Review on PTPN9, with data on DNA, on the protein encoded, and where the gene is implicated

    Feasibility of magnetic bead technology for concentration of mycobacteria in sputum prior to fluorescence microscopy

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Direct sputum smear microscopy is the mainstay of TB diagnosis in most low and middle income countries, and is highly specific for <it>Mycobacterium tuberculosis </it>in such settings. However it is limited by low sensitivity, particularly in HIV co-infected patients. Concentration by centrifugation has been reported to be more sensitive than direct smear preparation, but is only suitable for referral laboratories. Simpler concentration methods that could be applied in peripheral laboratories are urgently needed.</p> <p>Methods</p> <p>We evaluated the feasibility of an early prototype ligand-coated magnetic bead technology to concentrate <it>M. tuberculosis </it>prior to detection by LED-based fluorescence microscopy compared with direct Ziehl-Neelsen microscopy and direct and concentrated fluorescence microscopy in a reference laboratory in Kampala, Uganda. Results were compared with MGIT 960 liquid culture and Lowenstein-Jensen culture.</p> <p>Results</p> <p>Compared to culture, concentrated FM had significantly higher sensitivity than direct ZN (74.8% and 51.4%), magnetic bead-FM (65.4%) and direct FM (58.9%). The sensitivity of magnetic bead FM was significantly higher than direct ZN (p < 0.001) but not significantly higher than direct FM (p = 0.210). The specificity of magnetic bead FM and concentrated FM was significantly lower than direct ZN (88.6%, 94.3% and 98.9% respectively) and direct FM (99.4%). There was no significant difference in specificity between magnetic bead FM and concentrated FM. Allowing for blinded resolution of discrepant results, the specificity of magnetic bead FM increased to 93.1%. Direct microscopy was simpler than concentrated FM and Magnetic bead FM which both had a similar number of steps.</p> <p>Conclusion</p> <p>The sensitivity of the early prototype magnetic bead FM was lower than concentrated FM, similar to direct FM, and significantly higher than direct ZN. Both magnetic bead and concentration by centrifugation led to reduced specificity compared with the direct smear methods. Some magnetic bead FM false positive results were not easily explained and should be further investigated. The prototype version of the magnetic bead procedure tested here was of similar complexity to concentration by centrifugation. As such, if the sensitivity of the magnetic bead FM could be improved in future versions of the technology, this may offer a viable alternative to centrifugation.</p

    Performance of Three LED-Based Fluorescence Microscopy Systems for Detection of Tuberculosis in Uganda

    Get PDF
    BACKGROUND: Direct smear microscopy using Ziehl-Neelsen (ZN) staining is the mainstay of tuberculosis (TB) diagnosis in most high burden countries, but is limited by low sensitivity in routine practice, particularly in high human immunodeficiency virus (HIV) prevalence settings. METHODS: We compared the performance of three commercial light emitting diode (LED)-based microscopy systems (Primostar™ iLED, Lumin™ and AFTER®) for fluorescent detection of Mycobacterium tuberculosis with ZN microscopy on slides prepared from sputum of TB suspects. Examination time for LED-based fluorescent microscopy (LED FM) and ZN slides was also compared, and a qualitative user appraisal of the LED FM systems was carried out. RESULTS: LED FM was between 5.6 and 9.4% more sensitive than ZN microscopy, although the difference was not statistically significant. There was no significant difference in the sensitivity or specificity of the three LED FM systems, although the specificity of Fraen AFTER was somewhat lower than the other LED FM methods. Examination time for LED FM was 2 and 4 times less than for ZN microscopy. LED FM was highly acceptable to Ugandan technologists, although differences in operational performance of the three systems were reported. CONCLUSIONS: LED FM compares favourably with ZN microscopy, with equivalent specificity and a modest increase in sensitivity. Screening of slides was substantially quicker using LED FM than ZN, and LED FM was rated highly by laboratory technologists. Available commercial systems have different operational characteristics which should be considered prior to programmatic implementation

    Rapid screening of MDR-TB using molecular Line Probe Assay is feasible in Uganda

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>About 500 new smear-positive Multidrug-resistant tuberculosis (MDR-TB) cases are estimated to occur per year in Uganda. In 2008 in Kampala, MDR-TB prevalence was reported as 1.0% and 12.3% in new and previously treated TB cases respectively. Line probe assays (LPAs) have been recently approved for use in low income settings and can be used to screen smear-positive sputum specimens for resistance to rifampicin and isoniazid in 1-2 days.</p> <p>Methods</p> <p>We assessed the performance of a commercial line probe assay (Genotype MTBDR<it>plus</it>) for rapid detection of rifampicin and isoniazid resistance directly on smear-positive sputum specimens from 118 previously treated TB patients in a reference laboratory in Kampala, Uganda. Results were compared with MGIT 960 liquid culture and drug susceptibility testing (DST). LPA testing was also performed in parallel in a University laboratory to assess the reproducibility of results.</p> <p>Results</p> <p>Overall, 95.8% of smear-positive specimens gave interpretable results within 1-2 days using LPA. Sensitivity, specificity, positive and negative predictive values were 100.0%, 96.1%, 83.3% and 100.0% for detection of rifampicin resistance; 80.8%, 100.0%, 100.0% and 93.0% for detection of isoniazid resistance; and 92.3%, 96.2%, 80.0% and 98.7% for detection of multidrug-resistance compared with conventional results. Reproducibility of LPA results was very high with 98.1% concordance of results between the two laboratories.</p> <p>Conclusions</p> <p>LPA is an appropriate tool for rapid screening for MDR-TB in Uganda and has the potential to substantially reduce the turnaround time of DST results. Careful attention must be paid to training, supervision and adherence to stringent laboratory protocols to ensure high quality results during routine implementation.</p

    PIP5K1A (phosphatidylinositol-4-phosphate 5-kinase type 1 alpha)

    No full text
    Review on PIP5K1A, with data on DNA, on the protein encoded, and where the gene is implicated
    corecore