161 research outputs found

    Agreement, repeatability, and reproducibility of quantitative retinal layer assessment using swept-source and spectral-domain optical coherence tomography in eyes with retinal diseases

    Get PDF
    PurposeTo evaluate the agreement and precision of retinal thickness measurements obtained using swept-source optical coherence tomography (SS-OCT) and spectral-domain OCT (SD-OCT) in healthy eyes and eyes with retinopathy.MethodsThis cross-sectional prospective study involved three DRI-OCT Triton (SS-OCT) and three 3D-OCT-1 Maestro (SD-OCT) devices. One of each device (Maestro and Triton) was paired with a single operator. Healthy subjects and patients with retinal diseases were recruited, with study eye and testing order randomized. At least 3 scans per eye were captured for wide scan (12 mm × 9 mm-Triton and Maestro) and macular cube scan (7 mm × 7 mm-Triton, 6 mm × 6 mm-Maestro). Thickness of the full retina, ganglion cell layer + inner plexiform layer (GCL+), and ganglion cell complex (GCL++) were obtained from wide scan and cube scans. Agreement of the measurements between the Triton and Maestro was evaluated by Bland–Altman analysis and Deming regression for each group. Repeatability and reproducibility were assessed using a two-way random effect analysis of variance (ANOVA) model for each parameter by group.ResultsTwenty-five healthy subjects (25 eyes) and 26 patients with retinal diseases (26 eyes), including, but not limited to, age-related macular degeneration, macular hole, and diabetic retinopathy were recruited. Overall, the measurement differences between Triton and Maestro were <6 μm (mean differences of full retina, GCL++, and GCL+ thickness were ≤5.5 μm, 1.3 μm, and 2.8 μm, respectively) and not statistically significant across the parameters. The repeatability and reproducibility estimates indicate high precision in both devices and groups. Across all the parameters, the repeatability limit was ≤7.6 μm for Triton and ≤12.7 μm for Maestro; reproducibility limit was ≤9.2 μm for Triton and ≤14.4 μm for Maestro. In eyes with retinal pathology, the repeatability coefficient of variation (CV)% was ≤2.6% for Triton and ≤3.4% for Maestro; reproducibility CV% was ≤3.3% for Triton and ≤3.5% for Maestro.ConclusionBoth Triton SS-OCT and Maestro SD-OCT provide reliable measurements of retinal thickness in healthy eyes and eyes with retinal diseases. Excellent agreement between the two devices indicates interoperability when testing healthy eyes or eyes with retinal pathology. These findings support the use of thickness measurements from Triton SS-OCT and Maestro SD-OCT in clinical practice

    Adjustment of Insulin Pump Settings in Type 1 Diabetes Management: Advisor Pro Device Compared to Physicians’ Recommendations

    Get PDF
    Aims: To compare insulin dose adjustments made by physicians to those made by an artificial intelligence-based decision support system, the Advisor Pro, in people with type 1 diabetes (T1D) using an insulin pump and self-monitoring blood glucose (SMBG). Methods: This was a multinational, non-interventional study surveying 17 physicians from 11 countries. Each physician was asked to provide insulin dose adjustments for the settings of the pump including basal rate, carbohydrate-to-insulin ratios (CRs), and correction factors (CFs) for 15 data sets of pumps and SMBG of people with T1D (mean age 18.4 ± 4.8 years; eight females; mean glycated hemoglobin 8.2% ± 1.4% [66 ± 11mmol/mol]). The recommendations were compared among the physicians and between the physicians and the Advisor Pro. The study endpoint was the percentage of comparison points for which there was an agreement on the direction of insulin dose adjustments. Results: The percentage (mean ± SD) of agreement among the physicians on the direction of insulin pump dose adjustments was 51.8% ± 9.2%, 54.2% ± 6.4%, and 49.8% ± 11.6% for the basal, CR, and CF, respectively. The automated recommendations of the Advisor Pro on the direction of insulin dose adjustments were comparable)49.5% ± 6.4%, 55.3% ± 8.7%, and 47.6% ± 14.4% for the basal rate, CR, and CF, respectively(and noninferior to those provided by physicians. The mean absolute difference in magnitude of change between physicians was 17.1% ± 13.1%, 14.6% ± 8.4%, and 23.9% ± 18.6% for the basal, CR, and CF, respectively, and comparable to the Advisor Pro 11.7% ± 9.7%, 10.1% ± 4.5%, and 25.5% ± 19.5%, respectively, significant for basal and CR. Conclusions: Considerable differences in the recommendations for changes in insulin dosing were observed among physicians. Since automated recommendations by the Advisor Pro were similar to those given by physicians, it could be considered a useful tool to manage T1D

    Development, Capabilities, and Impact on Wind Analyses of the Hurricane Imaging Radiometer (HIRAD)

    Get PDF
    The Hurricane Imaging Radiometer (HIRAD) is a new airborne microwave remote sensor for hurricane observations that is currently under development by NASA Marshall Space Flight Center in partnership with the NOAA Atlantic Oceanographic and Meteorological Laboratory/Hurricane Research Division, the University of Central Florida, the University of Michigan, and the University of Alabama in Huntsville. The instrument is being test flown in January and is expected to participate in the tropical cyclone experiment GRIP (Genesis and Rapid Intensification Processes) in the 2010 season. HIRAD is being designed to study the wind field in some detail within strong hurricanes and to enhance the real-time airborne ocean surface winds observation capabilities of NOAA and USAF Weather Squadron hurricane hunter aircraft currently using the operational Stepped Frequency Microwave Radiometer (SFMR). Unlike SFMR, which measures wind speed and rain rate along the ground track at a single point directly beneath the aircraft, HIRAD will provide images of the surface wind and rain field over a wide swath (approximately 3 x the aircraft altitude) with approximately 2 km resolution. This paper describes the HIRAD instrument and the physical basis for its operations, including chamber test data from the instrument. The potential value of future HIRAD observations will be illustrated with a summary of Observing System Simulation Experiments (OSSEs) in which measurements from the new instrument as well as those from existing instruments (air, surface, and space-based) are simulated from the output of a detailed numerical model, and those results are used to construct simulated H*Wind analyses. Evaluations will be presented on the impact on H*Wind analyses of using the HIRAD instrument observations to replace those of the SFMR instrument, and also on the impact of a future satellite-based HIRAD in comparison to instruments with more limited capabilities for observing strong winds through heavy rain. Potential impact on numerical prediction of hurricane intensity will also be discussed

    Bacteraemia among severely malnourished children infected and uninfected with the human immunodeficiency virus-1 in Kampala, Uganda

    Get PDF
    BACKGROUND: To establish the magnitude of bacteraemia in severely malnourished children, and describe the types of bacteria and antimicrobial sensitivity by HIV status. METHOD: Isolates were recovered from 76 blood specimens. Antibiotic susceptibility tests were performed using commercial antibiotic disks and demographic and clinical findings were recorded. RESULTS: Of the 450 children 63% were male; median age 17.0 months (inter quartile range, IQR 12–24) and 57% had oedema. 151 (36.7 %) of 411 tested HIV-positive; 76 (17.1%) of 445 blood specimens grew bacterial isolates; 58% were Gram negative – S. typhimurium (27.6%) and S. enteriditis (11.8%). Staph. aureus (26.3%) and Strep. pneumoniae (13.2%) were the main Gram positive organisms. There was no difference in the risk of bacteraemia by HIV status, age < 24 months, male sex, or oedema, except for oral thrush (OR 2.3 CI 1.0–5.1) and hypoalbuminaemia (OR 3.5 CI 1.0–12.1). Isolates from severely immuno-suppressed children (CD4% <15%) were more likely to grow Salmonella enteriditis (OR 5.4; CI 1.6 – 17.4). The isolates were susceptible (≥ 80%) to ciprofloxacin, ceftriaxone and gentamicin; with low susceptibility to chlorampenicol, ampicillin (< 50%) and co-trimoxazole (<25%). Suspicion of bacteraemia had 95.9% sensitivity and 99.2% specificity. Among bacteraemic children, mortality was higher (43.5% vs 20.5%) in the HIV-positive; OR 3.0 (95%CI 1.0, 8.6). CONCLUSION: Bacteraemia affects 1 in every 6 severely malnourished children and carries high mortality especially among the HIV-positive. Given the high level of resistance to common antibiotics, there is need for clinical trials to determine the best combinations of antibiotics for management of bacteraemia in severely malnourished children

    Comparison of Methods for Detection of Blastocystis Infection in Routinely Submitted Stool Samples, and also in IBS/IBD Patients in Ankara, Turkey

    Get PDF
    BACKGROUND: This study compared diagnostic methods for identifying Blastocystis in stool samples, and evaluated the frequency of detection of Blastocystis in patients with irritable bowel syndrome (IBS) and inflammatory bowel disease (IBD). RESULTS AND DISCUSSION: From a set of 105 stool specimens submitted for routine parasitological analysis, 30 were identified as positive for Blastocystis by the culture method. From that group of 30 positives, Lugol's stain, trichrome staining, and an immunofluorescence assay identified 11, 15, and 26 samples as positive respectively. Using culture as a standard, the sensitivity of Lugol's stain was 36.7%, trichrome staining was 50%, and the IFA stain was 86.7%. The specificity of Lugol's stain was 91%, trichrome staining was 100%, and the IFA stain was 97.3%. In the group of 27 IBS and IBD patients, using all methods combined, we detected Blastocystis in 67% (18/27) of the patients. Blastocystis was detected in 33% (2/6) of IBD patients and 76% (16/21) of IBS patients. For comparison, trichrome staining alone, the method most frequently used in many countries, would have only identified Blastocystis infection in 29% (6/21) of the IBS patients. No parasitic co-infections were identified in the IBS/IBD patients. Most Blastocystis-positive IBS/IBD patients were over 36 with an average length of illness of 4.9 years. CONCLUSIONS: Most IBS patients in this study were infected with Blastocystis. IFA staining may be a useful alternative to stool culture, especially if stool specimens have been chemically preserved

    Consensus Recommendations for the Use of Automated Insulin Delivery (AID) Technologies in Clinical Practice

    Get PDF
    International audienceThe significant and growing global prevalence of diabetes continues to challenge people with diabetes (PwD), healthcare providers and payers. While maintaining near-normal glucose levels has been shown to prevent or delay the progression of the long-term complications of diabetes, a significant proportion of PwD are not attaining their glycemic goals. During the past six years, we have seen tremendous advances in automated insulin delivery (AID) technologies. Numerous randomized controlled trials and real-world studies have shown that the use of AID systems is safe and effective in helping PwD achieve their long-term glycemic goals while reducing hypoglycemia risk. Thus, AID systems have recently become an integral part of diabetes management. However, recommendations for using AID systems in clinical settings have been lacking. Such guided recommendations are critical for AID success and acceptance. All clinicians working with PwD need to become familiar with the available systems in order to eliminate disparities in diabetes quality of care. This report provides much-needed guidance for clinicians who are interested in utilizing AIDs and presents a comprehensive listing of the evidence payers should consider when determining eligibility criteria for AID insurance coverage
    corecore