64 research outputs found

    Hydroxyapatite coating does not improve uncemented stem survival after total hip arthroplasty!: An analysis of 116,069 THAs in the Nordic Arthroplasty Register Association (NARA) database

    Get PDF
    Background and purpose — It is still being debated whether HA coating of uncemented stems used in total hip arthroplasty (THA) improves implant survival. We therefore investigated different uncemented stem brands, with and without HA coating, regarding early and long-term survival. Patients and methods — We identified 152,410 THA procedures using uncemented stems that were performed between 1995 and 2011 and registered in the Nordic Arthroplasty Register Association (NARA) database. We excluded 19,446 procedures that used stem brands less than 500 times in each country, procedures performed due to diagnoses other than osteoarthritis or pediatric hip disease, and procedures with missing information on the type of coating. 22 stem brands remained (which were used in 116,069 procedures) for analysis of revision of any component. 79,192 procedures from Denmark, Norway, and Sweden were analyzed for the endpoint stem revision. Unadjusted survival rates were calculated according to Kaplan-Meier, and Cox proportional hazards models were fitted in order to calculate hazard ratios (HRs) for the risk of revision with 95% confidence intervals (CIs). Results — Unadjusted 10-year survival with the endpoint revision of any component for any reason was 92.1% (CI: 91.8–92.4). Unadjusted 10-year survival with the endpoint stem revision due to aseptic loosening varied between the stem brands investigated and ranged from 96.7% (CI: 94.4–99.0) to 99.9% (CI: 99.6–100). Of the stem brands with the best survival, stems with and without HA coating were found. The presence of HA coating was not associated with statistically significant effects on the adjusted risk of stem revision due to aseptic loosening, with an HR of 0.8 (CI: 0.5–1.3; p = 0.4). The adjusted risk of revision due to infection was similar in the groups of THAs using HA-coated and non-HA-coated stems, with an HR of 0.9 (CI: 0.8–1.1; p = 0.6) for the presence of HA coating. The commonly used Bimetric stem (n = 25,329) was available both with and without HA coating, and the adjusted risk of stem revision due to aseptic loosening was similar for the 2 variants, with an HR of 0.9 (CI: 0.5–1.4; p = 0.5) for the HA-coated Bimetric stem. Interpretation — Uncemented HA-coated stems had similar results to those of uncemented stems with porous coating or rough sand-blasted stems. The use of HA coating on stems available both with and without this surface treatment had no clinically relevant effect on their outcome, and we thus question whether HA coating adds any value to well-functioning stem designs.publishedVersio

    Uncemented and cemented primary total hip arthroplasty in the Swedish Hip Arthroplasty Register: Evaluation of 170,413 operations

    Get PDF
    BACKGROUND AND PURPOSE: Since the introduction of total hip arthroplasty (THA) in Sweden, both components have most commonly been cemented. A decade ago the frequency of uncemented fixation started to increase, and this change in practice has continued. We therefore analyzed implant survival of cemented and uncemented THA, and whether the modes of failure differ between the two methods of fixation. PATIENTS AND METHODS: All patients registered in the Swedish Hip Arthroplasty Register between 1992 and 2007 who received either totally cemented or totally uncemented THA were identified (n = 170,413). Kaplan-Meier survival analysis with revision of any component, and for any reason, as the endpoints was performed. Cox regression models were used to calculate risk ratios (RRs) for revision for various reasons, adjusted for sex, age, and primary diagnosis. RESULTS: Revision-free 10-year survival of uncemented THA was lower than that of cemented THA (85% vs. 94%, p < 0.001). No age or diagnosis groups benefited from the use of uncemented fixation. Cox regression analysis confirmed that uncemented THA had a higher risk of revision for any reason (RR = 1.5, 95% CI: 1.4-1.6) and for aseptic loosening (RR = 1.5, CI: 1.3-1.6). Uncemented cup components had a higher risk of cup revision due to aseptic loosening (RR = 1.8, CI: 1.6-2.0), whereas uncemented stem components had a lower risk of stem revision due to aseptic loosening (RR = 0.4, CI: 0.3-0.5) when compared to cemented components. Uncemented stems were more frequently revised due to periprosthetic fracture during the first 2 postoperative years than cemented stems (RR = 8, CI: 5-14). The 5 most common uncemented cups had no increased risk of revision for any reason when compared with the 5 most commonly used cemented cups (RR = 0.9, CI: 0.6-1.1). There was no significant difference in the risk of revision due to infection between cemented and uncemented THA. INTERPRETATION: Survival of uncemented THA is inferior to that of cemented THA, and this appears to be mainly related to poorer performance of uncemented cups. Uncemented stems perform better than cemented stems; however, unrecognized intraoperative femoral fractures may be an important reason for early failure of uncemented stems. The risk of revision of the most common uncemented cup designs is similar to that of cemented cups, indicating that some of the problems with uncemented cup fixation may have been solved.Open Access - This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the source is credited

    No increased mortality after total hip arthroplasty in patients with a history of pediatric hip disease : a matched, population-based cohort study on 4,043 patients.

    No full text
    Background and purpose - Patients with pediatric hip diseases are more comorbid than the general population and at risk of premature, secondary osteoarthritis, often leading to total hip arthroplasty (THA). We investigated whether THA confers an increased mortality in this cohort.Patients and methods - We identified 4,043 patients with a history of Legg-Calvé-Perthes disease (LCPD), slipped capital femoral epiphysis (SCFE), or developmental dysplasia of the hip (DDH) in the Swedish Hip Arthroplasty Register (SHAR) between 1992 and 2012. For each patient, we matched 5 controls from the general population for age, sex, and place of residence, and acquired information on all participants' socioeconomic background and comorbidities. Mortality after THA was estimated according to Kaplan-Meier, and Cox proportional hazard models were fitted to estimate adjusted hazard ratios (HRs) for the risk of death.Results - Compared with unexposed individuals, patients exposed to a THA due to pediatric hip disease had lower incomes, lower educational levels, and a higher degree of comorbidity but a statistically non-significant attenuation of 90-day mortality (HR 0.9; 95% CI 0.4-2.0) and a lower risk of overall mortality (HR 0.8; CI 0.7-0.9).Interpretation - Patients exposed to THA due to a history of pediatric hip disease have a slightly lower mortality than unexposed individuals. THA seems not to confer increased mortality risks, even in these specific patients with numerous risk factors

    Concentrations of Cobalt, Chromium and Titanium and Immunological Changes after Primary Total Knee Arthroplasty—A Cohort Study with an 18-Year Follow-Up

    No full text
    Background: Total knee arthroplasty (TKA) generates elevated metal ion concentrations, but long-term changes in the concentrations of cobalt (Co), chromium (Cr) and titanium (Ti) after primary TKA and potential subsequent immune system activation—not limited to the joint but systemically—are not known. Patients and Methods: We conducted a cohort study on 26 patients with TKA (19 women; 16 with metal-backed and 10 with all-polyethylene tibial components) 18.3 years (min. 16.7, max. 20.5) after index TKA. A total of 69% of patients additionally underwent subsequent arthroplasty of the contralateral knee or either hip after the index surgery. Blood samples were analysed by inductively coupled plasma–mass spectrometry, and leukocytes were characterised by flow cytometry. Patients were clinically assessed using the Knee Society score and by plain radiography of the knee. Results: The median metal ion concentrations were 0.7 (0.1–13.0) µg/L for Co, 0.9 (0.4–5.0) µg/L for Cr, and 1.0 (0.2–13.0) µg/L for Ti. There was no relevant difference in systemic metal ion concentrations between patients exposed to single and multiple arthroplasties. The absolute count and proportion of CD3+CD4+CD8+ T cells was inversely correlated with both Co (rho −0.55, p = 0.003) and Cr concentrations (rho −0.59, p = 0.001). Conclusions: Between the first and second decades after primary TKA, in most patients, the concentrations of Co, Cr and Ti in blood samples were below the thresholds that are considered alarming. The negative correlation of Co and Cr concentrations with a subset of lymphocytes that commonly increases during immune activation is reassuring. This represents a worst-case scenario, underscoring that the investigated metal ions remain within reasonable ranges, even after additional hardware exposure
    • …
    corecore