42 research outputs found
Crystal growth and characterization of the dilutable frustrated spin-ladder compound Bi(Cu1-xZnx)(2)PO6
High quality centimeter size single crystals of Bi(Cu1-xZnx)(2)PO6 (x=0% 1% 5%) have been successfully grown by the Travelling Solvent Floating Zone (TSFZ) technique The crystals were grown with a rate of 1 mm/h in a gas mixture of 20% O-2 in Ar Characterization of the single crystal samples by means of optical microscopy X-ray powder diffraction X-ray Laue diffraction neutron diffraction and magnetization measurement are reported The magnetic susceptibility lambda(spin)(T) measured from 2 to 300 K passes a broad maximum around 60 K followed by an exponential decrease towards lower T and confirm the formation of a spin singlet ground state at low temperature At low-temperature a paramagnetic Curie-like upturn quantitatively reflect the increasing Zn-doping level (C) 2010 Elsevier B V All rights reserve
Corrosion behavior of friction stir welded lap joints of AA6061-T6 aluminum alloy
In this work, the corrosion behaviors of friction-stir lap welding of 6061-T6 Al-alloy are studied. The friction-stir lap welding was performed under different welding conditions (rotation speed and welding speed). The corrosion behavior of the parent alloy, the weld nugget zone (WNZ), and the heat affected zone (HAZ) of each welded sample working as an electrode, were investigated by the Tafel polarization test in 3.5 wt. (%) NaCl at ambient temperature. The morphology of the corroded surface of each region was analyzed by scanning electron microscopy together with energy dispersive spectroscopy (SEM-EDS). The results showed that the corrosion resistance of the parent alloy was better than the WNZ and the HAZ in both welding conditions. Localized pit dissolution and intergranular corrosion were the dominant corrosion types observed in the parent alloy, WNZ, and HAZ. The parent alloy, WNZ, and HAZ exhibited similar corrosion potentials (Ecorr) after T6 heat treatment. This treatment had a better effect on the corrosion resistance of the welded regions than the parent alloy
Efficacy of high-intensity, low-volume interval training compared to continuous aerobic training on insulin resistance, skeletal muscle structure and function in adults with metabolic syndrome: study protocol for a randomized controlled clinical trial (Intraining-MET)
ABSTRACT: Evidence of the efficacy of high-intensity, low-volume interval training (HIIT-low volume) in treating insulin resistance (IR) in patients with metabolic disorders is contradictory. In addition, it is unknown whether this effect is mediated through muscle endocrine function, which in turn depends on muscle mass and fiber type composition. Our aims were to assess the efficacy of HIIT-low volume compared to continuous aerobic exercise (CAE) in treating IR in adults with metabolic syndrome (MS) and to establish whether musclin, apelin, muscle mass and muscle composition are mediators of the effect. Methods: This is a controlled, randomized, clinical trial using the minimization method, with blinding of those who will evaluate the outcomes and two parallel groups for the purpose of showing superiority. Sixty patients with MS and IR with ages between 40 and 60 years will be included. A clinical evaluation will be carried out, along with laboratory tests to evaluate IR (homeostatic model assessment (HOMA)), muscle endocrine function (serum levels of musclin and apelin), thigh muscle mass (by dual energy x-ray absorptiometry (DXA) and thigh muscle composition (by carnosine measurement with proton magnetic resonance spectroscopy (H–MRS)), before and after 12 weeks of a treadmill exercise program three times a week. Participants assigned to the intervention (n = 30) will receive HIIT-low volume in 22-min sessions that will include six intervals at a load of 90% of maximum oxygen consumption (VO2 max) for 1 min followed by 2 min at 50% of VO2 max. The control group (n = 30) will receive CAE at an intensity of 60% of VO2 max for 36 min. A theoretical model based on structural equations will be proposed to estimate the total, direct and indirect effects of training on IR and the proportion explained by the mediators. Discussion: Compared with CAE, HIIT-low volume can be effective and efficient at improving physical capacity and decreasing cardiovascular risk factors, such as IR, in patients with metabolic disorders. Studies that evaluate mediating variables of the effect of HIIT-low volume on IR, such as endocrine function and skeletal muscle structure, are necessary to understand the role of skeletal muscle in the pathophysiology of MS and their regulation by exercise. Trial registration: NCT03087721. High-intensity Interval, Low Volume Training in Metabolic Syndrome (Intraining-MET). Registered on 22 March 2017, retrospectively registered
Frequency and clinical patterns of stroke in Iran - Systematic and critical review
<p>Abstract</p> <p>Background</p> <p>Cerebrovascular disease is the second commonest cause of death, and over a third of stroke deaths occur in developing countries. To fulfil the current gap on data, this systematic review is focused on the frequency of stroke, risk factors, stroke types and mortality in Iran.</p> <p>Methods</p> <p>Thirteen relevant articles were identified by keyword searching of PubMed, Iranmedex, Iranian University index Libraries and the official national data on burden of diseases.</p> <p>Results</p> <p>The publication dates ranged from 1990 to 2008. The annual stroke incidence of various ages ranged from 23 to 103 per 100,000 population. This is comparable to the figures from Arab Countries, higher than sub-Saharan Africa, but lower than developed countries, India, the Caribbean, Latin America, and China. Similarly to other countries, ischaemic stroke was the commonest subtype. Likewise, the most common related risk factor is hypertension in adults, but cardiac causes in young stroke. The 28-day case fatality rate is reported at 19-31%.</p> <p>Conclusions</p> <p>Data on the epidemiology of stroke, its pattern and risk factors from Iran is scarce, but the available data highlights relatively low incidence of stroke. This may reflect a similarity towards the neighbouring nations, and a contrast with the West.</p
Supernova neutrino detection in NOvA
The NOvA long-baseline neutrino experiment uses a pair of large, segmented, liquid-scintillator calorimeters to study neutrino oscillations, using GeV-scale neutrinos from the Fermilab NuMI beam. These detectors are also sensitive to the flux of neutrinos which are emitted during a core-collapse supernova through inverse beta decay interactions on carbon at energies of O(10 MeV). This signature provides a means to study the dominant mode of energy release for a core-collapse supernova occurring in our galaxy. We describe the data-driven software trigger system developed and employed by the NOvA experiment to identify and record neutrino data from nearby galactic supernovae. This technique has been used by NOvA to self-trigger on potential core-collapse supernovae in our galaxy, with an estimated sensitivity reaching out to 10 kpc distance while achieving a detection efficiency of 23% to 49% for supernovae from progenitor stars with masses of 9.6 M_⊙ to 27 M_⊙, respectively
First measurement of neutrino oscillation parameters using neutrinos and antineutrinos by NOvA
The NOvA experiment has seen a 4.4σ signal of ν̄e appearance in a 2 GeV ν̄μ beam at a distance of 810 km. Using 12.33×1020 protons on target delivered to the Fermilab NuMI neutrino beamline, the experiment recorded 27 ν̄μ→ν̄e candidates with a background of 10.3 and 102 ν̄μ→ν̄μ candidates. This new antineutrino data are combined with neutrino data to measure the parameters |Δm322|=2.48-0.06+0.11×10-3 eV2/c4 and sin2θ23 in the ranges from (0.53-0.60) and (0.45-0.48) in the normal neutrino mass hierarchy. The data exclude most values near δCP=π/2 for the inverted mass hierarchy by more than 3σ and favor the normal neutrino mass hierarchy by 1.9σ and θ23 values in the upper octant by 1.6σ
First measurement of neutrino oscillation parameters using neutrinos and antineutrinos by NOvA
The NOvA experiment has seen a
4.4
σ
signal of
¯
ν
e
appearance in a 2 GeV
¯
ν
μ
beam at a distance of 810 km. Using
12.33
×
10
20
protons on target delivered to the Fermilab NuMI neutrino beamline, the experiment recorded 27
¯
ν
μ
→
¯
ν
e
candidates with a background of 10.3 and 102
¯
ν
μ
→
¯
ν
μ
candidates. This new antineutrino data are combined with neutrino data to measure the parameters
|
Δ
m
2
32
|
=
2.4
8
+
0.11
−
0.06
×
10
−
3
eV
2
/
c
4
and
sin
2
θ
23
in the ranges from (0.53–0.60) and (0.45–0.48) in the normal neutrino mass hierarchy. The data exclude most values near
δ
C
P
=
π
/
2
for the inverted mass hierarchy by more than
3
σ
and favor the normal neutrino mass hierarchy by
1.9
σ
and
θ
23
values in the upper octant by
1.6
σ