140 research outputs found

    Theory for polymer coils with necklaces of micelles

    Get PDF
    If many micelles adsorb onto the same polymer molecule then they are said to form a necklace. A minimal model of such a necklace is proposed and shown to be almost equivalent to a 1-dimensional fluid with nearest-neighbour interactions. The thermodynamic functions of this fluid are obtained and then used to predict the change in the critical micellar concentration of the surfactant in the presence of the polymer. If the amount of polymer is not too large there are two critical micellar concentrations, one for micelles in necklaces and one for free micelles.Comment: 12 pages, 5 figure

    Vitamin-V: Virtual Environment and Tool-boxing for Trustworthy Development of RISC-V based Cloud Services

    Get PDF
    Vitamin-V is a 2023-2025 Horizon Europe project that aims to develop a complete RISC-V open-source software stack for cloud services with comparable performance to the cloud-dominant x86 counterpart and a powerful virtual execution environment for software development, validation, verification, and test that considers the relevant RISC-V ISA extensions for cloud deployment

    Search for Lorentz and CPT Violation Effects in Muon Spin Precession

    Full text link
    The spin precession frequency of muons stored in the (g2)(g-2) storage ring has been analyzed for evidence of Lorentz and CPT violation. Two Lorentz and CPT violation signatures were searched for: a nonzero Δωa\Delta\omega_{a} (=ωaμ+ωaμ\omega_{a}^{\mu^{+}}-\omega_{a}^{\mu^{-}}); and a sidereal variation of ωaμ±\omega_{a}^{\mu^{\pm}}. No significant effect is found, and the following limits on the standard-model extension parameters are obtained: bZ=(1.0±1.1)×1023b_{Z} =-(1.0 \pm 1.1)\times 10^{-23} GeV; (mμdZ0+HXY)=(1.8±6.0×1023)(m_{\mu}d_{Z0}+H_{XY}) = (1.8 \pm 6.0 \times 10^{-23}) GeV; and the 95% confidence level limits bˇμ+<1.4×1024\check{b}_{\perp}^{\mu^{+}}< 1.4 \times 10^{-24} GeV and bˇμ<2.6×1024\check{b}_{\perp}^{\mu^{-}} < 2.6 \times 10^{-24} GeV.Comment: 5 pages, 3 figures, submitted to Physical Review Letters, Modified to answer the referees suggestion

    ACTiCLOUD: Enabling the Next Generation of Cloud Applications

    Get PDF
    Despite their proliferation as a dominant computing paradigm, cloud computing systems lack effective mechanisms to manage their vast amounts of resources efficiently. Resources are stranded and fragmented, ultimately limiting cloud systems' applicability to large classes of critical applications that pose non-moderate resource demands. Eliminating current technological barriers of actual fluidity and scalability of cloud resources is essential to strengthen cloud computing's role as a critical cornerstone for the digital economy. ACTiCLOUD proposes a novel cloud architecture that breaks the existing scale-up and share-nothing barriers and enables the holistic management of physical resources both at the local cloud site and at distributed levels. Specifically, it makes advancements in the cloud resource management stacks by extending state-of-the-art hypervisor technology beyond the physical server boundary and localized cloud management system to provide a holistic resource management within a rack, within a site, and across distributed cloud sites. On top of this, ACTiCLOUD will adapt and optimize system libraries and runtimes (e.g., JVM) as well as ACTiCLOUD-native applications, which are extremely demanding, and critical classes of applications that currently face severe difficulties in matching their resource requirements to state-of-the-art cloud offerings

    An Improved Limit on the Muon Electric Dipole Moment

    Get PDF
    Three independent searches for an electric dipole moment (EDM) of the positive and negative muons have been performed, using spin precession data from the muon g-2 storage ring at Brookhaven National Laboratory. Details on the experimental apparatus and the three analyses are presented. Since the individual results on the positive and negative muon, as well as the combined result, d=-0.1(0.9)E-19 e-cm, are all consistent with zero, we set a new muon EDM limit, |d| < 1.9E-19 e-cm (95% C.L.). This represents a factor of 5 improvement over the previous best limit on the muon EDM.Comment: 19 pages, 15 figures, 7 table

    Final Report of the Muon E821 Anomalous Magnetic Moment Measurement at BNL

    Full text link
    We present the final report from a series of precision measurements of the muon anomalous magnetic moment, a_mu = (g-2)/2. The details of the experimental method, apparatus, data taking, and analysis are summarized. Data obtained at Brookhaven National Laboratory, using nearly equal samples of positive and negative muons, were used to deduce a_mu(Expt) = 11 659 208.0(5.4)(3.3) x 10^-10, where the statistical and systematic uncertainties are given, respectively. The combined uncertainty of 0.54 ppm represents a 14-fold improvement compared to previous measurements at CERN. The standard model value for a_mu includes contributions from virtual QED, weak, and hadronic processes. While the QED processes account for most of the anomaly, the largest theoretical uncertainty, ~0.55 ppm, is associated with first-order hadronic vacuum polarization. Present standard model evaluations, based on e+e- hadronic cross sections, lie 2.2 - 2.7 standard deviations below the experimental result.Comment: Summary paper of E821 Collaboration measurements of the muon anomalous magnetic moment, each reported earlier in Letters or Brief Reports; 96 pages, 41 figures, 16 tables. Revised version submitted to PR

    Search for Lorentz and CPT Violation Effects in Muon Spin Precession

    Full text link
    The spin precession frequency of muons stored in the (g2)(g-2) storage ring has been analyzed for evidence of Lorentz and CPT violation. Two Lorentz and CPT violation signatures were searched for: a nonzero Δωa\Delta\omega_{a} (=ωaμ+ωaμ\omega_{a}^{\mu^{+}}-\omega_{a}^{\mu^{-}}); and a sidereal variation of ωaμ±\omega_{a}^{\mu^{\pm}}. No significant effect is found, and the following limits on the standard-model extension parameters are obtained: bZ=(1.0±1.1)×1023b_{Z} =-(1.0 \pm 1.1)\times 10^{-23} GeV; (mμdZ0+HXY)=(1.8±6.0×1023)(m_{\mu}d_{Z0}+H_{XY}) = (1.8 \pm 6.0 \times 10^{-23}) GeV; and the 95% confidence level limits bˇμ+<1.4×1024\check{b}_{\perp}^{\mu^{+}}< 1.4 \times 10^{-24} GeV and bˇμ<2.6×1024\check{b}_{\perp}^{\mu^{-}} < 2.6 \times 10^{-24} GeV.Comment: 5 pages, 3 figures, submitted to Physical Review Letters, Modified to answer the referees suggestion

    Challenges in the harmonisation of global integrated assessment models: a comprehensive methodology to reduce model response heterogeneity

    Get PDF
    Harmonisation sets the ground to a solid inter-comparison of integrated assessment models. A clear and transparent harmonisation process promotes a consistent interpretation of the modelling outcomes divergences and, reducing the model variance, is instrumental to the use of integrated assessment models to support policy decision-making. Despite its crucial role for climate economic policies, the definition of a comprehensive harmonisation methodology for integrated assessment modelling remains an open challenge for the scientific community. This paper proposes a framework for a harmonisation methodology with the definition of indispensable steps and recommendations to overcome stumbling blocks in order to reduce the variance of the outcomes which depends on controllable modelling assumptions. The harmonisation approach of the PARIS REINFORCE project is presented here to layout such a framework. A decomposition analysis of the harmonisation process is shown through 6 integrated assessment models (GCAM, ICES-XPS, MUSE, E3ME, GEMINI-E3, and TIAM). Results prove the potentials of the proposed framework to reduce the model variance and present a powerful diagnostic tool to feedback on the quality of the harmonisation itself

    The Muon Anomalous Magnetic Moment and the Standard Model

    Full text link
    The muon anomalous magnetic moment measurement, when compared with theory, can be used to test many extensions to the standard model. The most recent measurement made by the Brookhaven E821 Collaboration reduces the uncertainty on the world average of a_mu to 0.7 ppm, comparable in precision to theory. This paper describes the experiment and the current theoretical efforts to establish a correct standard model reference value for the muon anomaly.Comment: Plenary Talk; PANIC'02 XVI Particles and Nuclear International Conference, Osaka, Japan; Sept. 30 - Oct. 4, 2002; Report describes the published 0.7 ppm result and updates the theory statu

    Measurement of the Negative Muon Anomalous Magnetic Moment to 0.7 ppm

    Full text link
    The anomalous magnetic moment of the negative muon has been measured to a precision of 0.7 parts per million (ppm) at the Brookhaven Alternating Gradient Synchrotron. This result is based on data collected in 2001, and is over an order of magnitude more precise than the previous measurement of the negative muon. The result a_mu= 11 659 214(8)(3) \times 10^{-10} (0.7 ppm), where the first uncertainty is statistical and the second is sytematic, is consistend with previous measurements of the anomaly for the positive and negative muon. The average for the muon anomaly a_{mu}(exp) = 11 659 208(6) \times 10^{-10} (0.5ppm).Comment: 4 pages, 4 figures, submitted to Physical Review Letters, revised to reflect referee comments. Text further revised to reflect additional referee comments and a corrected Fig. 3 replaces the older versio
    corecore