1,951 research outputs found

    The absorption spectrum of calcium vapor - 1660 - 2028 angstrom Scientific report no. 5

    Get PDF
    Absorption spectrum, atomic energy levels, and electron transitions for calcium vapor between 1660 to 2028 angstrom

    Oscillator strengths of the red autoionizing lines of calcium

    Get PDF
    Shock tube measurement of calcium autoionization line oscillator strength for use in stellar atmospheric model calculation

    Inverted Martian Craters in Lineated Glacial Valleys, Ismenius Lacus Region, Mars

    Get PDF
    We studied small, uniquely-shaped craters found on the surface of lineated terrain in the Ismenius Lacus region of Mars. By utilizing MOC and THEMIS satellite images, we located terrain including lineations (viscous flow features), smoothing of topography, and morphologic features such as polygons and gullies, which appear to be strong evidence of preexisting ice deposits

    Variable Corticosteroid Sensitivity of Thymic Cortex and Medullary Peripheral-type Lymphoid Tissue in Myasthenia Gravis Patients: Structural and Functional Effects

    Get PDF
    The thymus has been studied in myasthenia gravis patients to assess the effects of previous immunosuppresslon on total yields of cell suspension, immunohistology and culture responses. The reduction in cell yields by pretreatment with corticosteroid was very variable. In 16 of 32 cases, cortical, medullary and total cell numbers were all greatly reduced (‘depleted cases'), whereas in the others, they were within or near the typical range for untreated myasthenics. Cortical thymocytes were even more depleted than precursor thymic blasts. Thus the interpatient differences in sensitivity to corticosteroid recently described for mature T cells also affected immature cortical thymocytes and their differentiating medullary progeny.In the medulla, mature (CD3+)T lymphocytes and germinal centres were enriched by the loss of cortex and appeared relatively healthy, but somewhat depopulated. Concomitantly, in-vitro T-cell responses to acetylcholine receptor (AChR) and production of anti-A ChR antibody and total IgG by thymic cells were usually well within the typical range (assessed per 106 cells). Moreover, the total productivity of the entire thymus was reduced almost entirely by the cellular depopulation rather than by decreased function per surviving cell. Thus the main actions of this alternate day therapy with corticosteroids were apparently on total peripheral cell numbers, and perhaps on activated cells and effector mechanisms too, and its thymic effects were inessentia

    Beam Test Results of the BTeV Silicon Pixel Detector

    Get PDF
    The results of the BTeV silicon pixel detector beam test carried out at Fermilab in 1999-2000 are reported. The pixel detector spatial resolution has been studied as a function of track inclination, sensor bias, and readout threshold.Comment: 8 pages of text, 8 figures, Proceedings paper of Pixel 2000: International Workshop on Semiconductor Pixel Detectors for Particles and X-Rays, Genova, June 5-8, 200

    Performance of prototype BTeV silicon pixel detectors in a high energy pion beam

    Get PDF
    The silicon pixel vertex detector is a key element of the BTeV spectrometer. Sensors bump-bonded to prototype front-end devices were tested in a high energy pion beam at Fermilab. The spatial resolution and occupancies as a function of the pion incident angle were measured for various sensor-readout combinations. The data are compared with predictions from our Monte Carlo simulation and very good agreement is found.Comment: 24 pages, 20 figure

    Beam Test of BTeV Pixel Detectors

    Full text link
    The silicon pixel vertex detector is one of the key elements of the BTeV spectrometer. Detector prototypes were tested in a beam at Fermilab. We report here on the measured spatial resolution as a function of the incident angles for different sensor-readout electronics combinations. We compare the results with predictions from our Monte Carlo simulation.Comment: 7 pages, 5 figures, Invited talk given by J.C. Wang at "Vertex 2000, 9th International Workshop on Vertex Detectors", Michigan, Sept 10-15, 2000. To be published in NIM

    Apatites in Gale Crater

    Get PDF
    ChemCam is an active remote sensing instrument suite that has operated successfully on MSL since landing Aug. 6th, 2012. It uses laser pulses to remove dust and to analyze rocks up to 7 m away. Laser-induced breakdown spectroscopy (LIBS) obtains emission spectra of materials ablated from the samples in electronically excited states. The intensities of the emission lines scale with the abundances of the related element. ChemCam is sensitive to most major rock-forming elements as well as to a set of minor and trace elements such as F, Cl, Li, P, Sr, Ba, and Rb. The measured chemical composition can then be used to infer the mineralogical composition of the ablated material. Here, we report a summary of inferred apatite detections along the MSL traverse at Gale Crater. We present the geologic settings of these findings and derive some interpretations about the formation conditions of apatite in time and space

    Improving Practice Accessibility Through MyChart Utilization

    Get PDF
    Aims for Improvement Increase patient portal MyChart activation for a cohort of approximately 2,000 patients at JFMA by 1% from February to April 2021. Demonstrate evidence of utilization including appointment scheduling, results review, and communication with providers through MyChart after activation
    corecore