2,037 research outputs found
A 64-pixel Positron-Sensitive Surgical Probe
We report on the continued development of a 64-pixel positron-sensitive surgical probe with a dual-layer detector and multi-anode PMT. An 8 x 8 array of this plastic scintillators in teh first layer detects positrons and a matched GSO crystal array in the second layer detects annihilation 511 keV gammas, which are required to be in coincidence with the detected positrons. Also, the 64 PMT anode signals are differentiated and an overshoot threshold is applied to separate the fast decay plastic anode signals from the slower GSO signals. Finally, an energy threshold is applied to the summed anode signal to distinguish 511 keV gammas from the 140 keV gammas commonly used in sentinel lymph node (SLN) surgery. Previously we reported on how these signal selection criteria were individually tested and optimized based on 9 channels of prototype electronics [1-2]. Currently the electronics shave been upgraded to Xilinx® programmable components, allowing on-the-fly alteration of signal selection criteria, and all 64 channels are operational. Initial measurements of the complete 64-pixel probe were conducted using 18F-FDG positron sources and 18F-FDG and 99mTcphantoms (background 511 keV and 140 keV gammas), simulating lesions in the SLN surgery environment. The average positron sensitivity is measured to be 3.0-7.0 kcps/µCi at different signal selection criteria. The lower bound on sensitivity corresponds to settings optimized for high image resolution and high background rejection ability. The upper bound on sensitivity corresponds to settings optimized for high sensitivity at the cost of lower image resolution and lower background rejection ability. The measured true-to-background contrast in the presence of clinically observed levels of 511 keV and 140 keV background gammas is ~3:1 for a tumor-to-background uptake ratio of 5:1. Performance measurements of the complete 64-pixel probe including sensitivity, true-to-background ratio, and the pixel separation ability are presented
Attitudes Towards and Limitations to ICT Use in Assisted and Independent Living Communities: Findings from a Specially-Designed Technological Intervention
Much literature has been devoted to theoretical explanations of the learning processes of older adults and to the methods of teaching best utilized in older populations. However, there has been less focus on the education of older adults who reside in assisted and independent living communities (AICs), especially with regards to information and communication technology (ICT) education. The purpose of this study is to determine whether participants\u27 attitudes and views towards computers and the Internet are affected as a result of participating in an eight-week training program designed to enhance computer and Internet use among older adults in such communities. Specifically, we examine if ICT education specially designed for AIC residents results in more positive attitudes towards ICTs and a perceived decrease in factors that may limit or prevent computer and Internet use. We discuss the implications of these results for enhancing the quality of life for older adults in AICs and make recommendations for those seeking to decrease digital inequality among older adults in these communities through their own ICT classes
Adiposity, hepatic triglyceride, and carotid intima media thickness during behavioral weight loss treatment in antipsychotic-treated youth: A randomized pilot study
The HERA-B Ring Imaging Cherenkov Counter
The HERA-B RICH uses a radiation path length of 2.8 m in C_4F_10 gas and a
large 24 square meters spherical mirror for imaging Cherenkov rings. The photon
detector consists of 2240 Hamamatsu multi-anode photomultipliers with about
27000 channels. A 2:1 reducing two-lens telescope in front of each PMT
increases the sensitive area at the expense of increased pixel size, resulting
in a contribution to the resolution which roughly matches that of dispersion.
The counter was completed in January of 1999, and its performance has been
steady and reliable over the years it has been in operation. The design
performance of the RICH was fully reached: the average number of detected
photons in the RICH for a beta=1 particle was found to be 33 with a single hit
resolution of 0.7 mrad and 1 mrad in the fine and coarse granularity regions,
respectively.Comment: 29 pages, 23 figure
The HADES Tracking System
The tracking system of the dielectron spectrometer HADES at GSI Darmstadt is
formed out of 24 low-mass, trapezoidal multi-layer drift chambers providing in
total about 30 square meter of active area. Low multiple scattering in the in
total four planes of drift chambers before and after the magnetic field is
ensured by using helium-based gas mixtures and aluminum cathode and field
wires. First in-beam performance results are contrasted with expectations from
simulations. Emphasis is placed on the energy loss information, exploring its
relevance regarding track recognition.Comment: 6 pages, 4 figures, presented at the 10th Vienna Conference on
Instrumentation, Vienna, February 2004, to be published in NIM A (special
issue
Recommended from our members
Geology, hydrology, chemistry, and microbiology of the in situ bioremediation demonstration site
This report summarizes characterization information on the geology, hydrology, microbiology, contaminant distribution, and ground-water chemistry to support demonstration of in situ bioremediation at the Hanford Site. The purpose of this information is to provide baseline conditions, including a conceptual model of the aquifer being utilized for in situ bioremediation. Data were collected from sampling and other characterization activities associated with three wells drilled in the upper part of the suprabasalt aquifer. Results of point-dilution tracer tests, conducted in the upper 9 m (30 ft) of the aquifer, showed that most ground-water flow occurs in the upper part of this zone, which is consistent with hydraulic test results and geologic and geophysical data. Other tracer test results indicated that natural ground-water flow velocity is equal to or less than about 0.03 m/d (0.1 ft/d). Laboratory hydraulic conductivity measurements, which represent the local distribution of vertical hydraulic conductivity, varied up to three orders of magnitude. Based on concentration data from both the vadose and saturated zone, it is suggested that most, if not all, of the carbon tetrachloride detected is representative of the aqueous phase. Concentrations of carbon tetrachloride, associated with a contaminant plume in the 200-West Area, ranged from approximately 500 to 3,800 {mu}g/L in the aqueous phase and from approximately 10 to 290 {mu}g/L in the solid phase at the demonstration site. Carbon tetrachloride gas was detected in the vadose zone, suggesting volatilization and subsequent upward migration from the saturated zone
Measurement of the rate of nu_e + d --> p + p + e^- interactions produced by 8B solar neutrinos at the Sudbury Neutrino Observatory
Solar neutrinos from the decay of B have been detected at the Sudbury
Neutrino Observatory (SNO) via the charged current (CC) reaction on deuterium
and by the elastic scattering (ES) of electrons. The CC reaction is sensitive
exclusively to nu_e's, while the ES reaction also has a small sensitivity to
nu_mu's and nu_tau's. The flux of nu_e's from ^8B decay measured by the CC
reaction rate is
\phi^CC(nu_e) = 1.75 +/- 0.07 (stat)+0.12/-0.11 (sys.) +/- 0.05(theor) x 10^6
/cm^2 s.
Assuming no flavor transformation, the flux inferred from the ES reaction
rate is
\phi^ES(nu_x) = 2.39+/-0.34 (stat.)+0.16}/-0.14 (sys) x 10^6 /cm^2 s.
Comparison of \phi^CC(nu_e) to the Super-Kamiokande Collaboration's precision
value of \phi^ES(\nu_x) yields a 3.3 sigma difference, providing evidence that
there is a non-electron flavor active neutrino component in the solar flux. The
total flux of active ^8B neutrinos is thus determined to be 5.44 +/-0.99 x
10^6/cm^2 s, in close agreement with the predictions of solar models.Comment: 6 pages (LaTex), 3 figures, submitted to Phys. Rev. Letter
A double-sided, shield-less stave prototype for the ATLAS upgrade strip tracker for the high luminosity LHC
A detailed description of the integration structures for the barrel region of the silicon strips tracker of the ATLAS Phase-II upgrade for the upgrade of the Large Hadron Collider, the so-called High Luminosity LHC (HL-LHC), is presented. This paper focuses on one of the latest demonstrator prototypes recently assembled, with numerous unique features. It consists of a shortened, shield-less, and double sided stave, with two candidate power distributions implemented. Thermal and electrical performances of the prototype are presented, as well as a description of the assembly procedures and tools
Adaptation of a mobile interactive obesity treatment approach for early severe mental illness: Protocol for a mixed methods implementation and pilot randomized controlled trial
BACKGROUND: Obesity is common in individuals with severe mental illness (SMI), contributing to a significantly shortened lifespan when compared to the general population. Available weight loss treatments have attenuated efficacy in this population, underscoring the importance of prevention and early intervention.
OBJECTIVE: Here, we describe a type 1 hybrid study design for adapting and pilot-testing an existing mobile health intervention for obesity prevention in individuals with early SMI and Class I or early-stage obesity, defined as a BMI of 30-35.
METHODS: An existing, evidence-based interactive obesity treatment approach using low-cost, semiautomated SMS text messaging was selected for adaptation. Community mental health clinics and Clubhouse settings in Eastern Missouri and South Florida were identified to participate. This study has the following 3 aims. First, using the Enhanced Framework for Reporting Adaptations and Modifications to Evidence-based interventions, contextual aspects of the clinical and digital treatment environments are identified for adaptation, considering 5 main stakeholder groups (clinical administrators, prescribing clinicians, case managers, nurses, and patients). Following a 2-week trial of unadapted SMS text messaging, Innovation Corps methods are used to discover needed intervention adaptations by stakeholder group and clinical setting. Second, adaptations to digital functionality and intervention content will be made based on themes identified in aim 1, followed by rapid usability testing with key stakeholders. A process for iterative treatment adaptation will be developed for making unplanned modifications during the aim 3 implementation pilot study. Individuals working in partner community mental health clinics and Clubhouse settings will be trained in intervention delivery. Third, in a randomized pilot and feasibility trial, adults with 5 years or less of treatment for an SMI diagnosis will be randomized 2:1 to 6 months of an adapted interactive obesity treatment approach or to an attentional control condition, followed by a 3-month extension phase of SMS text messages only. Changes in weight, BMI, and behavioral outcomes, as well as implementation challenges, will be evaluated at 6 and 9 months.
RESULTS: Institutional review board approval for aims 1 and 2 was granted on August 12, 2018, with 72 focus group participants enrolled; institutional review board approval for aim 3 was granted on May 6, 2020. To date, 52 participants have been enrolled in the study protocol.
CONCLUSIONS: In this type 1 hybrid study design, we apply an evidence-based treatment adaptation framework to plan, adapt, and feasibility test a mobile health intervention in real-world treatment settings. Resting at the intersection of community mental health treatment and physical health promotion, this study aims to advance the use of simple technology for obesity prevention in individuals with early-stage mental illness.
TRIAL REGISTRATION: ClinicalTrials.gov NCT03980743; https://clinicaltrials.gov/ct2/show/NCT03980743.
INTERNATIONAL REGISTERED REPORT IDENTIFIER (IRRID): DERR1-10.2196/42114
Isometric force production parameters during normal and experimental low back pain conditions
BACKGROUND: The control of force and its between-trial variability are often taken as critical determinants of motor performance. Subjects performed isometric trunk flexion and extension forces without and with experiment pain to examine if pain yields changes in the control of trunk forces. The objective of this study is to determine if experimental low back pain modifies trunk isometric force production. METHODS: Ten control subjects participated in this study. They were required to exert 50 and 75% of their isometric maximal trunk flexion and extension torque. In a learning phase preceding the non painful and painful trials, visual and verbal feedbacks were provided. Then, subjects were asked to perform 10 trials without any feedback. Time to peak torque, time to peak torque variability, peak torque variability as well as constant and absolute error in peak torque were calculated. Time to peak and peak dF/dt were computed to determine if the first peak of dF/dt could predict the peak torque achieved. RESULTS: Absolute and constant errors were higher in the presence of a painful electrical stimulation. Furthermore, peak torque variability for the higher level of force was increased with in the presence of experimental pain. The linear regressions between peak dF/dt, time to peak dF/dt and peak torque were similar for both conditions. Experimental low back pain yielded increased absolute and constant errors as well as a greater peak torque variability for the higher levels of force. The control strategy, however, remained the same between the non painful and painful condition. Cutaneous pain affects some isometric force production parameters but modifications of motor control strategies are not implemented spontaneously. CONCLUSIONS: It is hypothesized that adaptation of motor strategies to low back pain is implemented gradually over time. This would enable LBP patients to perform their daily tasks with presumably less pain and more accuracy
- …