79 research outputs found

    Marked variation in newborn resuscitation practice: a national survey in the UK

    Get PDF
    Abstract Background Although international newborn resuscitation guidance has been in force for some time, there are no UK data on current newborn resuscitation practices. Objective Establish delivery room (DR) resuscitation practices in the UK, and identify any differences between neonatal intensive care units (NICU), and other local neonatal services. Methods We conducted a structured two-stage survey of DR management, among UK neonatal units during 2009–2010 (n = 192). Differences between NICU services (tertiary level) and other local neonatal services (non-tertiary) were analysed using Fisher's exact and Student's t-tests. Results There was an 89% response rate (n = 171). More tertiary NICUs institute DR CPAP than non-tertiary units (43% vs. 16%, P = 0.0001) though there was no significant difference in frequency of elective intubation and surfactant administration for preterm babies. More tertiary units commence DR resuscitation in air (62% vs. 29%, P < 0.0001) and fewer in 100% oxygen (11% vs. 41%, P < 0.0001). Resuscitation of preterm babies in particular, commences with air in 56% of tertiary units. Significantly more tertiary units use DR pulse oximeters (58% vs. 29%, P < 0.01) and titrate oxygen based on saturations. Almost all services use occlusive wrapping to maintain temperature for preterm infants. Conclusions In the UK, there are many areas of good evidence based DR practice. However, there is marked variation in management, including between units of different designation, suggesting a need to review practice to fulfil new resuscitation guidance, which will have training and resource implications

    Inhaled Nitric Oxide in preterm infants: a systematic review and individual patient data meta-analysis

    Get PDF
    BACKGROUND: Preterm infants requiring assisted ventilation are at significant risk of both pulmonary and cerebral injury. Inhaled Nitric Oxide, an effective therapy for pulmonary hypertension and hypoxic respiratory failure in the full term infant, has also been studied in preterm infants. The most recent Cochrane review of preterm infants includes 11 studies and 3,370 participants. The results show a statistically significant reduction in the combined outcome of death or chronic lung disease (CLD) in two studies with routine use of iNO in intubated preterm infants. However, uncertainty remains as a larger study (Kinsella 2006) showed no significant benefit for iNO for this combined outcome. Also, trials that included very ill infants do not demonstrate significant benefit. One trial of iNO treatment at a later postnatal age reported a decrease in the incidence of CLD. The aim of this individual patient meta-analysis is to confirm or refute these potentially conflicting results and to determine the extent to which patient or treatment characteristics may explain the results and/or may predict benefit from inhaled Nitric Oxide in preterm infants. METHODS/DESIGN: The Meta-Analysis of Preterm Patients on inhaled Nitric Oxide (MAPPiNO) Collaboration will perform an individual patient data meta-analysis to answer these important clinical questions. Studies will be included if preterm infants receiving assisted ventilation are randomized to receive inhaled Nitric Oxide or to a control group. The individual patient data provided by the Collaborators will be analyzed on an intention-to-treat basis where possible. Binary outcomes will be analyzed using log-binomial regression models and continuous outcomes will be analyzed using linear fixed effects models. Adjustments for trial differences will be made by including the trial variable in the model specification. DISCUSSION: Thirteen (13) trials, with a total of 3567 infants are eligible for inclusion in the MAPPiNO systematic review. To date 11 trials (n = 3298, 92% of available patients) have agreed to participate. Funding was successfully granted from Ikaria Inc as an unrestricted grant. A collaborative group was formed in 2006 with data collection commencing in 2007. It is anticipated that data analysis will commence in late 2009 with results being publicly available in 2010

    Neonatal outcomes of extremely preterm infants from the NICHD Neonatal Research Network.

    Get PDF
    OBJECTIVE: This report presents data from the Eunice Kennedy Shriver National Institute of Child Health and Human Development Neonatal Research Network on care of and morbidity and mortality rates for very low birth weight infants, according to gestational age (GA). METHODS: Perinatal/neonatal data were collected for 9575 infants of extremely low GA (22-28 weeks) and very low birth weight (401-1500 g) who were born at network centers between January 1, 2003, and December 31, 2007. RESULTS: Rates of survival to discharge increased with increasing GA (6% at 22 weeks and 92% at 28 weeks); 1060 infants died at CONCLUSION: Although the majority of infants with GAs of \u3eor=24 weeks survive, high rates of morbidity among survivors continue to be observed

    Association Between Oxygen Saturation Targeting and Death or Disability in Extremely Preterm Infants in the Neonatal Oxygenation Prospective Meta-analysis Collaboration

    Get PDF
    Importance There are potential benefits and harms of hyperoxemia and hypoxemia for extremely preterm infants receiving more vs less supplemental oxygen. Objective To compare the effects of different target ranges for oxygen saturation as measured by pulse oximetry (Spo2) on death or major morbidity. Design, Setting, and Participants Prospectively planned meta-analysis of individual participant data from 5 randomized clinical trials (conducted from 2005-2014) enrolling infants born before 28 weeks’ gestation. Exposures Spo2 target range that was lower (85%-89%) vs higher (91%-95%). Main Outcomes and Measures The primary outcome was a composite of death or major disability (bilateral blindness, deafness, cerebral palsy diagnosed as ≥2 level on the Gross Motor Function Classification System, or Bayley-III cognitive or language score <85) at a corrected age of 18 to 24 months. There were 16 secondary outcomes including the components of the primary outcome and other major morbidities. Results A total of 4965 infants were randomized (2480 to the lower Spo2 target range and 2485 to the higher Spo2 range) and had a median gestational age of 26 weeks (interquartile range, 25-27 weeks) and a mean birth weight of 832 g (SD, 190 g). The primary outcome occurred in 1191 of 2228 infants (53.5%) in the lower Spo2 target group and 1150 of 2229 infants (51.6%) in the higher Spo2 target group (risk difference, 1.7% [95% CI, −1.3% to 4.6%]; relative risk [RR], 1.04 [95% CI, 0.98 to 1.09], P = .21). Of the 16 secondary outcomes, 11 were null, 2 significantly favored the lower Spo2 target group, and 3 significantly favored the higher Spo2 target group. Death occurred in 484 of 2433 infants (19.9%) in the lower Spo2 target group and 418 of 2440 infants (17.1%) in the higher Spo2 target group (risk difference, 2.8% [95% CI, 0.6% to 5.0%]; RR, 1.17 [95% CI, 1.04 to 1.31], P = .01). Treatment for retinopathy of prematurity was administered to 220 of 2020 infants (10.9%) in the lower Spo2 target group and 308 of 2065 infants (14.9%) in the higher Spo2 target group (risk difference, −4.0% [95% CI, −6.1% to −2.0%]; RR, 0.74 [95% CI, 0.63 to 0.86], P < .001). Severe necrotizing enterocolitis occurred in 227 of 2464 infants (9.2%) in the lower Spo2 target group and 170 of 2465 infants (6.9%) in the higher Spo2 target group (risk difference, 2.3% [95% CI, 0.8% to 3.8%]; RR, 1.33 [95% CI, 1.10 to 1.61], P = .003). Conclusions and Relevance In this prospectively planned meta-analysis of individual participant data from extremely preterm infants, there was no significant difference between a lower Spo2 target range compared with a higher Spo2 target range on the primary composite outcome of death or major disability at a corrected age of 18 to 24 months. The lower Spo2 target range was associated with a higher risk of death and necrotizing enterocolitis, but a lower risk of retinopathy of prematurity treatment

    Act now against new NHS competition regulations: an open letter to the BMA and the Academy of Medical Royal Colleges calls on them to make a joint public statement of opposition to the amended section 75 regulations.

    Get PDF

    Safety and Effectiveness of Meropenem in Infants With Suspected or Complicated Intra-abdominal Infections

    Get PDF
    Background. Intra-abdominal infections are common in young infants and lead to significant morbidity and mortality. Meropenem is a broad-spectrum antimicrobial with excellent activity against pathogens associated with intra-abdominal infections. The purpose of this study was to determine the safety and effectiveness of meropenem in young infants with suspected or complicated intra-abdominal infections

    Impact of Optimized Breastfeeding on the Costs of Necrotizing Enterocolitis in Extremely Low Birthweight Infants

    Get PDF
    To estimate risk of NEC for ELBW infants as a function of preterm formula and maternal milk (MM) intake and calculate the impact of suboptimal feeding on NEC incidence and costs

    Recent advances in the management of lung disease of prematurity

    No full text

    Anatomy-driven design of a prototype video laryngoscope for extremely low birth weight infants

    No full text
    Extremely low birth weight (ELBW) infants frequently require endotracheal intubation for assisted ventilation or as a route for administration of drugs or exogenous surfactant. In adults and less premature infants, the risks of this intubation can be greatly reduced using video laryngoscopy, but current products are too large and incorrectly shaped to visualize an ELBW infant's airway anatomy. We design and prototype a video laryngoscope using a miniature camera set in a curved acrylic blade with a 3×6-mm cross section at the tip. The blade provides a mechanical structure for stabilizing the tongue and acts as a light guide for an LED light source, located remotely to avoid excessive local heating at the tip. The prototype is tested on an infant manikin and found to provide sufficient image quality and mechanical properties to facilitate intubation. Finally, we show a design for a neonate laryngoscope incorporating a wafer-level microcamera that further reduces the tip cross section and offers the potential for low cost manufacture
    • …
    corecore