47 research outputs found

    Relationships between reproduction parameters in dairy cows

    Get PDF
    The aim of the reproductive management of dairy farms is to keep low the days in milk (DIM). Milk production can be profitable only in that case. Calvings make only low DIM. From the economic point of view, to evaluate the amount of the calving is not simple because in many cases the insemination and the calving are not in the same year. We wanted to find a reproduction parameter, which is easy to record, available real time, and corrrelate well with other parameters. We collected reproduction data from 21 farms from 2016. Average numbers of cows, number of the ai (artificial insemination) in cows, number of cows pregnancies, open days (OD), service period (SP), time of first ai (TFAI), conception rate of first ai (CRFAI), conception rate of all ai (CRSAI) were collected. The number of the pregnant cows were grouped, pregancies under 120 days after calving -U120- and pregnancies above 200 -A200- days after calving. The economical effect of open days are well-known. OD correlated with the rate of the pregnancies under 120 days after calving (r = -0.802; P ≤ 0.001). The open days correlated with the rate of the pregnancis above 200 days after calving (r = 0.889; P ≤ 0.001). If the rate of U120 is high, the rate of pregnant cows (ROPC) will be high too (r = 0.611; P = 0.003). A200 is in negative relation with ROPC (r = -0.525; P = 0.015). OD correlated with TFAI (r = 0.562; P = 0.008). ROPC correlated with TFAI (r = -0.457; P = 0.037). OD correlated with SP (r = 0.778; P ≤ 0.001). SP is in negative correlation with CRFAI and CRSAI (r = - 0.577, P = 0.006; r = - 0.773, P ≤ 0.001). SP correlated with U120 and A200 (r= - 0.572, P = 0.007; r = 0.788 P ≤ 0.001). Our study shows that the rate of the pregnant cows are stasistically correlated with many important reproduction parameters. The measurement of the number of pregnant cows is easy, available real time and it has important economical effect on milk production. In summary, the number of pregnant cows is a useful parameter to evaluate the reproductive performance and current status of the farms

    Az elektródasor visszatekeredésének kimutatása transzimpedanciamátrix (TIM)-vizsgálattal cochlearis implantátumban = Detection of “tip fold-over” of the cochlear implant electrode array with transimpedance matrix (TIM) measurement

    Get PDF
    Összefoglaló. Bevezetés: Az elmúlt években a cochlearis implantátum a súlyos halláskárosodás vagy a teljes siketség rutinszerű és hatékony kezelési eszközévé vált. Korunk egyik leggyakrabban használt és leghatékonyabb újítása a cochlearis implantációban a perimodiolaris vékony elektródasorok alkalmazása. A cochlea középtengelyét, a modiolust szorosan ölelő atraumatikus elektródasor igen meggyőző eredménnyel bizonyítja népszerűségét, mind az elektrofiziológiai mérések során, mind az akusztikus hallás megőrzése terén nyújtott teljesítményével. Ugyanakkor igen kevés publikáció írja le az elektródasor nem megfelelő helyzetének előfordulási gyakoriságát, pontosabban a visszatekeredését a csúcsi szakaszon. Célkitűzés: Tanulmányunk célja olyan szoftveres technika, a transzimpedancia-mátrix (TIM) beillesztése a rutin intraoperatív elektrofiziológiai mérési metodikák közé, amely képes objektív diagnosztikai lehetőséget biztosítani ahhoz, hogy korán felismerhessük a cochlearis implantátum elektródasorán keletkezett hurkot. Módszer: Hároméves kisgyermek kétoldali cochlearis implantációját követően, posztoperatív röntgenfelvételen a bal oldalon az elektródasor megfelelő pozíciója figyelhető meg, míg a jobb oldalon az intracochlearis elektródasor végének visszatekeredése igazolódott. Képalkotó vizsgálatot követően elektrofiziológiai metódusként TIM-vizsgálatot végeztünk. Az eljárás során a mérőeszköz a kijelölt stimuláló elektródákon 1 V nagyságrendű feszültséget közöl állandó áramerősség mellett a cochlea közel eső struktúrái felé. Mérőelektródák segítségével regisztráljuk a szöveteken mérhető feszültséget, majd transzimpedancia-mátrixszá alakítjuk a mért értékeket. Eredmények: Az elektródasor visszatekeredése, amelyet korábban radiológiai vizsgálattal igazoltunk, az objektív elektrofiziológiai mérések segítségével is jól azonosítható, és a vizsgálatok szoros párhuzamot mutatnak. Következtetés: Az elektródák helyzetének megjelenítésére szolgáló standard radiológiai képalkotási technikák kiegészíthetők, illetve kiválthatók egyszerűen elvégezhető, hatékony, objektív elektrofiziológiai vizsgálatokkal. Intraoperatíven, még a sebzárás előtt kimutatható, ha az elektródasor nem megfelelő helyzetbe került, így csökkenthetjük a radiológiai vizsgálatokkal járó sugárterhelés és annak finanszírozási problémáját. Orv Hetil. 2021; 162(25): 988-996. In recent years, the cochlear implant has become a routine and effective treatment tool for severe hearing loss and total deafness. One of the commonly used and effective innovations of our time in cochlear implantation is the perimodiolar thin electrode array. The atraumatic electrode array, which closely embraces the central axis of the cochlea (modiolus), has served its popularity with very convincing results, with its performance in both electrophysiological measurements and acoustic hearing preservation. However, very few publications describe the frequency of improper positioning of the electrode array, which is known as 'tip fold-over'.The aim of our study is to incorporate a software technique, the transimpedance matrix (TIM), into routine intraoperative electrophysiological measurement methodologies to provide a potential objective diagnostic opportunity for early detection of tip fold-over of the electrode array.Following bilateral cochlear implantation of a three-year-old child, postoperative radiography showed the correct position of the electrode array on the left side, while tip fold-over of the intracochlear electrode array was detected on the right side. Following imaging, a TIM study was performed as an electrophysiological method. During the procedure, the measuring device transmits a voltage of the order of 1 V to the nearby structures of the cochlea at a constant current at the designated stimulus electrodes. Measuring electrodes were used to register the voltage measured on the tissues, and then converted into a TIM.Electrode tip fold-over was previously diagnosed by radiological examination, while it can also be diagnosed by objective electrophysiological measurements now, and these two tests correlate well.Standard radiological imaging techniques for electrode positioning can be supplemented or replaced by easy-to-perform, effective objective electrophysiological studies. Tip fold-over can be detected intraoperatively, even before wound closure, if the electrode array is in the wrong position, thus reducing the radiation exposure associated with radiological examinations as well as reducing relevant costs. Orv Hetil. 2021; 162(25): 988-996

    Relationships between reproduction parameters in dairy cows

    Get PDF
    The aim of the reproductive management of dairy farms is to keep low the days in milk (DIM). Milk production can be profitable only in that case. Calvings make only low DIM. From the economic point of view, to evaluate the amount of the calving is not simple because in many cases the insemination and the calving are not in the same year. We wanted to find a reproduction parameter, which is easy to record, available real time, and corrrelate well with other parameters. We collected reproduction data from 21 farms from 2016. Average numbers of cows, number of the ai (artificial insemination) in cows, number of cows pregnancies, open days (OD), service period (SP), time of first ai (TFAI), conception rate of first ai (CRFAI), conception rate of all ai (CRSAI) were collected. The number of the pregnant cows were grouped, pregancies under 120 days after calving -U120- and pregnancies above 200 -A200- days after calving. The economical effect of open days are well-known. OD correlated with the rate of the pregnancies under 120 days after calving (r = -0.802; P ≤ 0.001). The open days correlated with the rate of the pregnancis above 200 days after calving (r = 0.889; P ≤ 0.001). If the rate of U120 is high, the rate of pregnant cows (ROPC) will be high too (r = 0.611; P = 0.003). A200 is in negative relation with ROPC (r = -0.525; P = 0.015). OD correlated with TFAI (r = 0.562; P = 0.008). ROPC correlated with TFAI (r = -0.457; P = 0.037). OD correlated with SP (r = 0.778; P ≤ 0.001). SP is in negative correlation with CRFAI and CRSAI (r = - 0.577, P = 0.006; r = - 0.773, P ≤ 0.001). SP correlated with U120 and A200 (r= - 0.572, P = 0.007; r = 0.788 P ≤ 0.001). Our study shows that the rate of the pregnant cows are stasistically correlated with many important reproduction parameters. The measurement of the number of pregnant cows is easy, available real time and it has important economical effect on milk production. In summary, the number of pregnant cows is a useful parameter to evaluate the reproductive performance and current status of the farms

    Versatility of microglial bioenergetic machinery under starving conditions

    Get PDF
    Microglia are highly dynamic cells in the brain. Their functional diversity and phenotypic versatility brought microglial energy metabolism into the focus of research. Although it is known that microenvironmental cues shape microglial phenotype, their bioenergetic response to local nutrient availability remains unclear. In the present study effects of energy substrates on the oxidative and glycolytic metabolism of primary - and BV-2 microglial cells were investigated. Cellular oxygen consumption, glycolytic activity, the levels of intracellular ATP/ADP, autophagy, mTOR phosphorylation, apoptosis and cell viability were measured in the absence of nutrients or in the presence of physiological energy substrates: glutamine, glucose, lactate, pyruvate or ketone bodies. All of the oxidative energy metabolites increased the rate of basal and maximal respiration. However, the addition of glucose decreased microglial oxidative metabolism and glycolytic activity was enhanced. Increased ATP/ADP ratio and cell viability, activation of the mTOR and reduction of autophagic activity were observed in glutamine-supplemented media. Moreover, moderate and transient oxidation of ketone bodies was highly enhanced by glutamine, suggesting that anaplerosis of the TCA-cycle could stimulate ketone body oxidation. It is concluded that microglia show high metabolic plasticity and utilize a wide range of substrates. Among them glutamine is the most efficient metabolite. To our knowledge these data provide the first account of microglial direct metabolic response to nutrients under short-term starvation and demonstrate that microglia exhibit versatile metabolic machinery. Our finding that microglia have a distinct bioenergetic profile provides a critical foundation for specifying microglial contributions to brain energy metabolism

    Cochlearis implantátumok különböző, előre görbített elektródasorainak elhelyezkedése a cochlea tengelyéhez viszonyítva. Radiológiai vizsgálat a perimodiolaritás mértékének megállapítására = The distance from the modiolus of perimodiolar electrode arrays of cochlear implants. A radiological study to evaluate the difference in perimodiolar properties

    Get PDF
    Absztrakt: Bevezetés: A cochlearis implantátumok elektródái gyártótól és modelltől függően különböznek hosszukban, vastagságukban és implantációt követően a csiga tengelyéhez (modiolushoz) viszonyított elhelyezkedésükben. Az előre görbített elektródasorok közelebb kerülnek a stimulálandó ganglion spirale sejtekhez, mint az egyenes elektródasorok, ami a stimulációban tapasztalt elektrofiziológiai különbségek mellett előnyös lehet a hangélmény minőségének szempontjából. Célkitűzés: Előzetes elektrofiziológiai vizsgálataink eredménye szerint ugyanannak a termékcsaládnak (Cochlear™ Nucleus® Profile) a vastagabb (Contour Advance) és vékonyabb (Slim Modiolar) perimodioláris elektródasorai közül a vékonyabbnak az elektródái hasonló töltésmennyiség átadása mellett is képesek hasonló idegi választ kiváltani, mint a vastagabbnak az elektródái. Vizsgálatunkkal arra kerestük a választ, hogy milyen jelenség áll az elektrofiziológiai eredmények hátterében. Módszer: Betegcsoportonként 54, Contour Advance és Slim Modiolar típusú elektródasorral implantáltakat vontunk be. Az elektródasor bevezetése minden esetben a kerek ablakon keresztül történt, a kerek ablak elülső-alsó csontszélének elfúrását követően vagy a nélkül. A műtét másnapján készült, Stenvers-féle röntgenfelvételeken megmértük az elektródasorok által leírt hurok cochleán belüli legnagyobb átmérőjét. A beültetés után két hónappal megbecsültük a kétféle perimodioláris elektródasorral felszerelt implantátum energiafelhasználási mutatóit. Eredmények: A posztoperatív röntgenfelvételeken a vékonyabb perimodioláris elektródasorral implantált csoportban az elektródasorok által leírt hurok cochleán belüli átlagos átmérője 4,2 ± 0,5 mm, míg a vastagabb perimodioláris elektródasorral implantált csoportban 4,9 ± 1,1 mm értéknek adódott. Az ’Auto power’ a CI532-csoportban 44,81 ± 5,05%, a CI512-csoportban 50,85 ± 8,35% volt, tehát alacsonyabb energiafogyasztást tapasztaltunk a CI532-csoportban. Következtetés: Képi diagnosztikai módszerrel, viszonylag nagy esetszám bevonásával arra következtettünk, hogy a vékonyabb perimodioláris elektródasor még a vastagabbnál is szignifikánsan közelebb kerül a modiolushoz, ami elfogadható magyarázatot ad előzetes elektrofiziológiai mérési eredményeinkre. Orv Hetil. 2019; 160(31): 1216–1222. | Abstract: Introduction: The cochlear implants vary in electrodes in terms of length, width and proximity to the modiolus. The precurved electrode arrays could be placed closer to the modiolus and the ganglion cells compared to straight electrodes. The two types of electrode arrays provide different electrophysiological characteristics; however, proximity to the modiolus may lead to better hearing performance. Aim: To investigate our preliminary electrophysiological results that suggest that the Slim Modiolar (SM) electrode array has the potential to elicit similar neural responses as the thicker perimodiolar (Contour Advance, CA) electrode from the same generation of implants. Method: Subjects that were implanted either with CA or SM electrodes were enrolled, 54 consecutive subjects in each group. All electrodes were introduced into the cochlea via the round window. The diameter of the largest turn of the electrode arrays within the cochlea was measured through postoperative radiography. The energy consumption parameters were estimated 2 months after implantation. Results: The mean of the largest turns of the arrays within the cochlea was 4.2 ± 0.5 mm in the SM group and 4.9 ± 1.1 mm in the CA group. ‘Auto power’ was 44.81 ± 5.05% and 50.85 ± 8.35% with SM and CA, respectively. Estimated energy consumption was lower with SM. The differences were statistically significant. Conclusion: Our measurements for a large cohort in each group suggest that the SM electrode array takes a significantly closer position to the modiolus than the CA. This finding supports our earlier electrophysiological result and indicates better performance abilities. Orv Hetil. 2019; 160(31): 1216–1222

    Continuous Camera-Based Premature-Infant Monitoring Algorithms for NICU

    Get PDF
    Non-contact visual monitoring of vital signs in neonatology has been demonstrated by several recent studies in ideal scenarios where the baby is calm and there is no medical or parental intervention. Similar to contact monitoring methods (e.g., ECG, pulse oximeter) the camera-based solutions suffer from motion artifacts. Therefore, during care and the infants’ active periods, calculated values typically differ largely from the real ones. In this way, our main contribution to existing remote camera-based techniques is to detect and classify such situations with a high level of confidence. Our algorithms can not only evaluate quiet periods, but can also provide continuous monitoring. Altogether, our proposed algorithms can measure pulse rate, breathing rate, and to recognize situations such as medical intervention or very active subjects using only a single camera, while the system does not exceed the computational capabilities of average CPU-GPU-based hardware. The performance of the algorithms was evaluated on our database collected at the Ist Dept. of Neonatology of Pediatrics, Dept of Obstetrics and Gynecology, Semmelweis University, Budapest, Hungary

    Studia Litteraria

    Get PDF
    KATONA GÁBOR: A szellemi test feltámadásának ígérete Dante: Az új élet címû mûvében p. 5-22. TÓTH JUDIT: Apokaliptikus testek és terek feminista módra p. 22-37. NAGY MARIANN: "Táncoló nõ az élet" - test és mûvészet a modernségben p. 37-64. KÁLAI SÁNDOR: Venus oszlásnak indul (Emile Zola: Nana) p. 64-75. MOLNÁR ÁDÁM: A test koncepciói és a szexualitás diszkurzusa John Updike Így látja Roger címû regényében p. 75-86. GYÜRKY KATALIN: Irina teste, avagy irodalmi és szexuális szerepkonfliktusok Viktor Jerofejev Az orosz széplány címû regényében p. 86-104. KOVÁCS MIKLÓS: A kert prezenciája Csehov Cseresznyéskert címû mûvében p. 104-122. TAKÁCS MIKLÓS: Hang(szín) és hang(test) A látás és hallás mint a numinózus érzet metaforái Ady és Rilke néhány Isten-versében p. 122-152. BERTA ERZSÉBET: Arché versus artefaktum. Az architektúra dekonstrukciójának kísérlete a dekonstruktivista építészetben és filozófiában p. 152-174. KRICSFALUSI BEATRIX: Testek ritmikus mozgása a térben Töredékek a testiség és színház történetiségének kapcsolatához p. 174-194. FAZEKAS ATTILA GYÕZÕ: A század fordul egyet. Nézõ-pont és jelentés Henry James: A csavar fordul egyet címû kisregényében p. 194-202
    corecore