33 research outputs found

    Risk assessment of exposure to particulate output of a demolition site.

    Get PDF
    Whilst vehicular and industrial contributions to the airborne particulate budget are well explored, the input due to building demolition is relatively unknown. Air quality is of importance to human health, and it is well known that composition of airborne particles can have a significant influence on both chronic and acute health effects. Road dust (RD) was collected before and after the demolition of a large building to elucidate changes in elemental profile. Rainfall and PM10 mass concentration data aided interpretation of the elemental data. Quantification of Al, As, Ba, Ca, Cd, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, Rh, S, Si, Sn, Ti, V and Zn was carried out. It was found that only Al, K, Mg, Si and S increased in concentration across all size fractions after the building demolition. Risk assessment was then carried out on elements with applicable reference dose values to assess the potential health risks due to the demolition. Significant risk to children was observed for chromium and aluminium exposure. PM10, monitored 40 metres from the demolition site, indicated no abnormal concentrations during the demolition; however, rainfall data were shown to affect the concentration of PM10. The elemental data observed in this study could possibly indicate the role of increased sulphur concentrations (in this case as a result of the demolition) on the buffer capacity of RD, hence leaching metals into rainwater

    Chromium speciation in solid matrices and regulation: A review

    No full text
    cited By 89International audienceIn recent years, the extensive use of chromium in industrial processes has led to the promotion of several directives and recommendations by the European Union, that try to limit and regulate the presence of Cr(VI) in the environment and to protect industrial workers using chromium and end-users of manufactured products. As a consequence, new standard methods and analytical procedures have been published at the EU level for Cr(VI) determination in soil, sludge, sediment, and similar waste materials, workplace atmospheres, cement, packaging materials, industrially produced samples, and corrosion-protection layers on some components of vehicles and electrical and electronic equipment. The objective of this article is to summarize the different directives and recommendations and to critically review the currently existing standard methods and the methods published in the literature for chromium speciation in the above mentioned solid matrices, putting the emphasis on the different extraction procedures which have been developed for each matrix. Particular attention has been paid to Cr(III) and Cr (VI) inter-conversions that can occur during extraction and efforts to minimize these unwanted reactions. Although the use of NaOH-Na2CO3 solutions with hot plate extraction seems to be the more widespread procedure, species transformation can still occur and several studies suggest that speciated isotope-dilution mass spectrometry (SIDMS) could be a suitable tool for correction of these interconversions. Besides, recent studies have proved the role of Cr(III) in chromium toxicology. As a consequence, the authors suggest an update of standard methods in the near future. © Springer-Verlag 2010

    Immunocytohistochemical characterization of pituitary cells of the bluefin tuna, Thunnus thynnus L

    Get PDF
    In this paper we report the first complete mapping of the pituitary in a tuna species. The various different adenohypophysis cell types of the bluefin tuna, Thunnus thynnus L. have been identified and located using different antisera against mammalian and piscine hormones and various histochemical techniques: PAS, Alcian Blue pH 2.5 and lectins -ConA and WGA- (Neutral and Acidic Glycoproteins); Bromophenol Blue (Proteins) and Tioglycollate-Ferric-Ferricianide-Fe111 (-S-S- groups). Prolactin (PRL) and adrenocorticotrophic (ACTH) cells were located in the rostral pars distalis (RPD) of the pituitary, while the proximal pars distalis (PPD) displayed gonadotrophic (GTH), thyrotrophic (TSH), somatotrophic (GH) and also a few PRL cells. Moreover, somatolactin (SL) and melanotrophic (MSH) cells were identified inside the pars intermedia (PI). Interestingly, some SL-immunoreactive fibers were dso detected in the neurohypophysis. Some GTH cells were also located on the exterior surface of the PI. Glycoproteins containing mannose (Man) andlor glucose (Glc); N-acetyl-glucosamine (GlcNAc) andlor sialic acid sugar residues, as well as -S-S- groups, were observed in GTH, TSH and SL cells. The Bromophenol Blue technique stained amphiphilic SL, acidophilic GH cells and weakly ACTH cells. GH and ACTH cells were unreactive to PAS, Alcian Blue, Tioglycollate-Ferric- Ferricianide-Fe111 and lectin (Con A and WGA) techniques. Finally, PAS reaction was positive in amphiphilic SL cells, which were PbH unreactive, while MSH and ACTH cells were stained with PbH technique

    Multi-residue analysis of pharmaceutical compounds in wastewaters by dual solid-phase microextraction coupled to liquid chromatography electrospray ionization ion trap mass spectrometry

    No full text
    The aim of this article is to present a new procedure based on dual solid-phase microextraction (dSPME) for the simultaneous extraction of 16 pharmaceutical compounds with acidic and basic characteristics in urban wastewaters. Water samples are divided into two aliquots of 2mL each extracted by two CW-TPR fibers at different pH values (pH 3 and 11) and with a NaCl concentration of 300gL-1 at 75°C for 30min. The analytes in both fibers are desorbed one after the other in the desorption chamber in static mode with mobile phase for 10min. The extracts are injected into an LC system coupled to an ion trap mass spectrometer, leading to the accurate quantification of 16 pharmaceutical compounds in wastewaters, in MS2 mode. All the target compounds found in wastewaters provide good signals corresponding to the protonated precursor ion M+H+. The parameters influencing adsorption and desorption of the analytes on fiber were optimized. The assessment of the analytical method was performed by studying the linearity (LOQ to 10ngmL-1) and the intra- and interday accuracy (89.2-109.7%) and precision (RSD <13.6%). The quantification limits obtained ranged between 0.005 and 0.05μgL-1. The application of the method to real samples proves its effectiveness in identifying and detecting naproxen, valsartan, bezafibrate, torasemide, diclofenac, carbamazepine, citalopram, lorazepan, fluoxetine, imipramine and amitriptyline in influent and effluent wastewater treatment plant samples

    Evaluation of Biomarkers for the Prediction of Venous Thromboembolism in Ambulatory Cancer Patients

    No full text
    Background: Venous thromboembolism (VTE) is a common complication of cancer. This study aimed to evaluate immature platelet fraction (IPF), mean platelet volume (MPV), P-selectin, D-dimer, and thrombin generation (TG) as predictive biomarkers for VTE and further the improvement of existing risk assessment models (RAMs). Methods: A prospective, observational, exploratory study was conducted on ambulatory cancer patients with indication for systemic chemotherapy. Baseline RAMs included the Khorana-, Vienna Cancer, Thrombosis-, Protecht-, ONKOTEV-, and Catscore. IPF, MPV, P-selectin, D-dimer, and TG were analysed at baseline and 3-month follow-up. Results: We enrolled 100 patients, of whom 89 completed the follow-up. Frequent tumour types were breast (30%), gastric (14%), gynaecological (14%), and colorectal (14%) cancer. Ten of the 89 patients (11.2%) developed VTE. The highest VTE rate was observed in patients with cholangiocarcinoma (3/5; 60%). Baseline D-dimer levels but not IPF, MPV, or P-selectin were associated with the risk of developing VTE (HR 6.9; p = 0.021). None of the RAMs showed statistical significance in predicting VTE. Peak thrombin and endogenous thrombin potential were lower in patients who developed VTE. Biomarker changes between baseline and follow-up were not associated with VTE risk. Conclusions: VTE risk was well predicted by baseline D-dimer levels. Adding D-dimer could improve existing RAMs to better identify patients who may benefit from primary VTE prophylaxis. The VTE risk among patients with cholangiocarcinoma should be further evaluated

    Evaluation of hexavalent chromium extraction method EPA method 3060A for soils using XANES spectroscopy

    No full text
    cited By 11International audienceHexavalent chromium (Cr(VI)) occurrence in soils is generally determined using an extraction step to transfer it to the liquid phase where it is more easily detected and quantified. In this work, the performance of the most common extraction procedure (EPA Method 3060A) using NaOH-Na2CO3 solutions is evaluated using X-ray absorption near edge structure spectroscopy (XANES), which enables the quantification of Cr(VI) directly in the solid state. Results obtained with both methods were compared for three solid samples with different matrices: a soil containing chromite ore processing residue (COPR), a loamy soil, and a paint sludge. Results showed that Cr(VI) contents determined by the two methods differ significantly, and that the EPA Method 3060A procedure underestimated the Cr(VI) content in all studied samples. The underestimation is particularly pronounced for COPR. Low extraction yield for EPA Method 3060A was found to be the main reason. The Cr(VI) present in COPR was found to be more concentrated in magnetic phases. This work provides new XANES analyses of SRM 2701 and its extraction residues for the purpose of benchmarking EPA 3060A performance. © 2011 American Chemical Society
    corecore