12,666 research outputs found

    ST/STIS Spectroscopy of the White Dwarfs in the Short-Period Dwarf Novae LL And and EF Peg

    Get PDF
    We present new HST/STIS observations of the short-period dwarf novae LL And and EF Peg during deep quiescence. We fit stellar models to the UV spectra and use optical and IR observations to determine the physical parameters of the whitedwarfs in the systems, the distances to the binaries, and the properties of thesecondary stars. Both white dwarfs are relatively cool, having T_{eff} near 15000K, and consistent with a mass of 0.6 M-sun. The white dwarf in LL And appears to be of solar abundance or slightly lower while that in EF Peg is near 0.1-0.3 solar. LL And is found to be 760 pc away while EF Peg is closer at 380 pc. EF Peg appears to have an ~M5V secondary star, consistent with that expected for its orbital period, while the secondary object in LL And remains a mystery.Comment: Accepted in Ap

    Noise suppression in inverse weak value based phase detection

    Get PDF
    We examine the effect of different sources of technical noise on inverse weak value-based precision phase measurements. We find that this type of measurement is similarly robust to technical noise as related experiments in the weak value regime. In particular, the measurements considered here are robust to additive Gaussian white noise and angular jitter noise commonly encountered in optical experiments. Additionally, we show the same techniques used for precision phase measurement can be used with the same technical advantages for optical frequency measurements.Comment: 6 pages, 4 figure

    Fluid thrust control system

    Get PDF
    A pure fluid thrust control system is described for a pump-fed, regeneratively cooled liquid propellant rocket engine. A proportional fluid amplifier and a bistable fluid amplifier control overshoot in the starting of the engine and take it to a predetermined thrust. An ejector type pump is provided in the line between the liquid hydrogen rocket nozzle heat exchanger and the turbine driving the fuel pump to aid in bringing the fluid at this point back into the regular system when it is not bypassed. The thrust control system is intended to function in environments too severe for mechanical controls

    Technical advantages for weak value amplification: When less is more

    Get PDF
    The technical merits of weak value amplification techniques are analyzed. We consider models of several different types of technical noise in an optical context and show that weak value amplification techniques (which only use a small fraction of the photons) compare favorably with standard techniques (which uses all of them). Using the Fisher information metric, we demonstrate that weak value techniques can put all of the Fisher information about the detected parameter into a small portion of the events and show how this fact alone gives technical advantages. We go on to consider a time correlated noise model, and find that a Fisher information analysis indicates that while the standard method can have much larger information about the detected parameter than the postselected technique. However, the estimator needed to gather the information is technically difficult to implement, showing that the inefficient (but practical) signal-to-noise estimation of the parameter is usually superior. We also describe other technical advantages unique to imaginary weak value amplification techniques, focusing on beam deflection measurements. In this case, we discuss combined noise types (such as detector transverse jitter, angular beam jitter before the interferometer and turbulence) for which the interferometric weak value technique gives higher Fisher information over conventional methods. We go on to calculate the Fisher information of the recently proposed photon recycling scheme for beam deflection measurements, and show it further boosts the Fisher information by the inverse postselection probability relative to the standard measurement case

    Gravitational sensing with weak value based optical sensors

    Get PDF
    Using weak values amplification angular resolution limits, we theoretically investigate the gravitational sensing of objects. By inserting a force-sensing pendulum into a weak values interferometer, the optical response can sense accelerations to a few 10's of zepto-g/Hz\mathrm{zepto}\text{-}\mathrm{g}/\sqrt{\mathrm{Hz}}, with optical powers of 1 mW1~\mathrm{mW}. We convert this precision into range and mass sensitivity, focusing in detail on simple and torsion pendula. Various noise sources present are discussed, as well as the necessary cooling that should be applied to reach the desired levels of precision.Comment: 9 pages, 4 figures, Quantum Stud.: Math. Found. (2018

    Experimental Violation of Two-Party Leggett-Garg Inequalities with Semi-weak Measurements

    Get PDF
    We generalize the derivation of Leggett-Garg inequalities to systematically treat a larger class of experimental situations by allowing multi-particle correlations, invasive detection, and ambiguous detector results. Furthermore, we show how many such inequalities may be tested simultaneously with a single setup. As a proof of principle, we violate several such two-particle inequalities with data obtained from a polarization-entangled biphoton state and a semi-weak polarization measurement based on Fresnel reflection. We also point out a non- trivial connection between specific two-party Leggett-Garg inequality violations and convex sums of strange weak values.Comment: 4 pages, 6 figure

    Quadruple Simulations of Thermographic Inspections of Impacted Composites

    Get PDF
    Thermography has been shown to be a viable technique for inspection of composites. Impact damage in composites typically contains multiple overlapping delaminations at different depths. Understanding the limitations of the thermographic inspection is enhanced by performing simulations of the technique. Most simulations of composite thermographic inspections have focused on simulations of a single delamination at a fixed depth. The quadrupole method has been shown as a viable technique for rapid three-dimensional thermographic simulations of a delamination. This method is expanded to enable rapid simulation of multiple overlapping delaminations at different depths. Quadrupole simulations are compared to finite element simulations of multiple delaminations at different depths. The simulations are also compared to the thermographic measurements on impacted composites where shape and depth of the delaminations are known from x-ray computed tomography data

    Precision frequency measurements with interferometric weak values

    Get PDF
    We demonstrate an experiment which utilizes a Sagnac interferometer to measure a change in optical frequency of 129 kHz per root Hz with only 2 mW of continuous wave, single mode input power. We describe the measurement of a weak value and show how even higher frequency sensitivities may be obtained over a bandwidth of several nanometers. This technique has many possible applications, such as precision relative frequency measurements and laser locking without the use of atomic lines.Comment: 4 pages, 3 figures, published in PR

    Ultrasensitive Beam Deflection Measurement via Interferometric Weak Value Amplification

    Get PDF
    We report on the use of an interferometric weak value technique to amplify very small transverse deflections of an optical beam. By entangling the beam's transverse degrees of freedom with the which-path states of a Sagnac interferometer, it is possible to realize an optical amplifier for polarization independent deflections. The theory for the interferometric weak value amplification method is presented along with the experimental results, which are in good agreement. Of particular interest, we measured the angular deflection of a mirror down to 560 femtoradians and the linear travel of a piezo actuator down to 20 femtometers
    corecore