57 research outputs found

    Forensic age estimation based on fast spin-echo proton density (FSE PD)-weighted MRI of the distal radial epiphysis.

    Get PDF
    Radiation exposure is a crucial factor to consider in forensic age estimation. The various magnetic resonance imaging (MRI) modalities used in forensic age estimation avoid radiation exposure. This study examined the reliability of distal radius ossification using fast spin-echo proton density (FSE PD)-weighted MRI to estimate age. Left wrist MRI findings of 532 patients aged 10-29 years were evaluated retrospectively using the five-stage system of Dedouit et al. The intra- and interobserver reliability values were κ = 0.906 and 0.869, respectively. Based on the results, the respective minimum ages estimated for stages 4 and 5 were 13.4 and 16.1 years for females, and 15.1 and 17.3 years for males; the method could not estimate an age of 18 years in any case. FSE PD MRI analysis of the distal radius epiphysis provides supportive data and can be used when evaluating the distal radius for forensic age estimation

    Measuring pelvises in 3D surface scans and in MDCT generated virtual environment: Considerations for applications in the forensic context.

    Get PDF
    Virtual Anthropology (VA) transposes the traditional methods of physical anthropology to virtual environments using imaging techniques and exploits imaging technologies to devise new methodological protocols. In this research, we investigate whether the measurements used in the Diagnose Sexuelle Probabiliste (DSP) and Ischio-Pubic Index (IPI) differ significantly when 3D models of a bone are generated using 3D surface scans (3DSS) and Multidetector Computed Tomography (MDCT) scans. Thirty pelvises were selected from the SIMON identified skeletal collection. An equal ratio of females to males was sought, as well as a good preservation of the bones. The pelvises were scanned using an MDCT scanner and a 3D surface scanner. The measurements of the DSP and IPI methods on the dry bones (referred to as macroscopic measurements here), and then to the 3D models. The intra- and interobserver, using the Technical Error of Measurement (TEM) and relative Technical Error of Measurement (rTEM) error was assessed, and we aimed to observe if the measurements made on the MDCT and 3DSS generated models were significantly different from those taken on the dry bones. Additionally, the normality of the data was tested (Shapiro-Wilk test) and the differences in measurements was evaluated using parametric (Student t-tests) and non-parametric (Wilcoxon) tests. The TEM and rTEM calculations show high intra and interobserver consistency in general. However, some measurements present insufficient inter- and intraobserver agreement. Student t and Wilcoxon tests indicate potentially significant differences of some measurements between the different environments. The results show that especially in the virtual environment, it is not easy to find the right angle for some of the DSP measurements, However, when comparing the measurement differences between dry and virtual bones, the results show that most of the differences are less than or equal to 2.5 mm. Considering the IPI, the landmarks are already difficult to determine on the dry bone, but they are even more difficult to locate in the virtual environment. Nevertheless, this study shows that quantitative methods may be better suited for application in the virtual environment, but further research using different methods is needed

    A model of online protection to reduce children's online risk exposure: empirical evidence from Asia

    Get PDF
    Children are surrounded by a variety of digital media and are exposed to potential risks that come with such easy accessibility. Learning how to be safe online is an important consideration for both children and their caregivers. The present study proposes an integrated model of online safety based on constructs from protection motivation theory and the health belief model, namely perceived severity of (and susceptibility to) risk, online self-efficacy, online privacy concern, and digital literacy. The study comprised a survey conducted among 420 schoolchildren aged 9–16 years. Using partial least squares-structural equation modelling, the results illustrated the presence of a negative effect of ‘perceived severity of online risk’ toward online risks, whereas the effect of ‘digital literacy’ was found to be positive. Children whose perception of online risks was more severe were less exposed to online risks if they had higher ‘online privacy concerns’ than the children with higher ‘digital literacy’ who are more exposed to online risk. Results of the study show that engaging in safe online behaviour requires children to have a high perception regarding severity of online risks as well as knowledge of online privacy concerns. Online risks and opportunities occur in parallel. Consequently, the factors that increase or decrease risk may also increase or decrease the benefits

    BMJ Open

    Get PDF
    INTRODUCTION: Worldwide, 2 million patients aged 18-50 years suffer a stroke each year, and this number is increasing. Knowledge about global distribution of risk factors and aetiologies, and information about prognosis and optimal secondary prevention in young stroke patients are limited. This limits evidence-based treatment and hampers the provision of appropriate information regarding the causes of stroke, risk factors and prognosis of young stroke patients. METHODS AND ANALYSIS: The Global Outcome Assessment Life-long after stroke in young adults (GOAL) initiative aims to perform a global individual patient data meta-analysis with existing data from young stroke cohorts worldwide. All patients aged 18-50 years with ischaemic stroke or intracerebral haemorrhage will be included. Outcomes will be the distribution of stroke aetiology and (vascular) risk factors, functional outcome after stroke, risk of recurrent vascular events and death and finally the use of secondary prevention. Subgroup analyses will be made based on age, gender, aetiology, ethnicity and climate of residence. ETHICS AND DISSEMINATION: Ethical approval for the GOAL study has already been obtained from the Medical Review Ethics Committee region Arnhem-Nijmegen. Additionally and when necessary, approval will also be obtained from national or local institutional review boards in the participating centres. When needed, a standardised data transfer agreement will be provided for participating centres. We plan dissemination of our results in peer-reviewed international scientific journals and through conference presentations. We expect that the results of this unique study will lead to better understanding of worldwide differences in risk factors, causes and outcome of young stroke patients

    Autoantibodies to central nervous system neuronal surface antigens: psychiatric symptoms and psychopharmacological implications

    Get PDF

    Ultrasonographic assessment of ossification of the distal radial epiphysis for estimating forensic age.

    Get PDF
    Since forensic age estimation is not a valid medical indication, research on the use of nonionizing methods is increasing. Ultrasonography is a radiological approach that protects patients from radiation exposure and offers special convenience to them. In this study, ultrasonography was used for age estimation by investigating the degree of ossification of the distal radial epiphysis. Its applicability on the Turkish population was investigated. The left wrist of 688 (322 males, 366 females) patients between the ages of 9 and 25 years was prospectively evaluated by ultrasonography. The intra- and interobserver reliabilities in evaluating the distal radial epiphysis and Cohen's kappa statistics show that the interobserver error was very low, and the kappa value was found to be 0.919. Stage 3 and 4 ossification of the distal radial epiphysis was first detected at age 14.3 and 15.3 years in males and 12.7 and 14.8 years in females, respectively. The data obtained may help determine legally critical age limits of 14 and 15. Although it does not seem useful for the age of 18, ultrasonography may be recommended in selected cases as a fast, inexpensive, frequently reproducible radiological method without concern about radiation and without a predictable health risk

    A novel surgical technique for prevention of Ahmed glaucoma valve tube exposure: long scleral flap augmented with Tenon advancement and duplication

    No full text
    Abstract Background To describe a new technique and present its long-term outcome for prevention of Ahmed glaucoma valve (AGV) tube exposure in patients with refractory glaucoma. Methods Twenty-seven eyes of 24 patients (mean age, 50 years; age range, 16–78 years; 8 females, 16 males) with refractory glaucoma who had the AGV implant were retrospectively reviewed. For AGV implantation, a long scleral flap combined with Tenon advancement and duplication was used. In this technique, a long scleral flap is created to completely cover the extraocular part of valve’s tube, and the flap surface is covered with duplicated Tenon’s tissue. The average follow-up after AGV implantation was 21.7 months (range, 12–36 months). Results The mean intraocular pressure before the operation, which was 44.1 mmHg (range, 26–62 mmHg), decreased to 14.2 mmHg (range, 8–20 mmHg) at the last follow-up visit, showing 67% reduction with AGV implantation. The mean number of antiglaucomatous medications was 4.1 before the AGV implantation and decreased to 0.9 after the operation, showing 88% reduction. In 14 eyes (51.9%), there was no change in the best corrected visual acuity (BCVA), and in 11 eyes (40.7%), the BCVA increased by 2 lines on the Snellen chart postoperatively. No patient developed postoperative hypotony, flat anterior chamber, diplopia, strabismus, erosion or exposure of the tube, or tube/plate migration. Conclusions The long scleral flap augmented with Tenon advancement and duplication is an effective and safe surgical technique for the implantation of AGV and preventing tube exposure in cases of refractory glaucoma
    corecore