3,317 research outputs found

    Quantum machine learning: a classical perspective

    Get PDF
    Recently, increased computational power and data availability, as well as algorithmic advances, have led machine learning techniques to impressive results in regression, classification, data-generation and reinforcement learning tasks. Despite these successes, the proximity to the physical limits of chip fabrication alongside the increasing size of datasets are motivating a growing number of researchers to explore the possibility of harnessing the power of quantum computation to speed-up classical machine learning algorithms. Here we review the literature in quantum machine learning and discuss perspectives for a mixed readership of classical machine learning and quantum computation experts. Particular emphasis will be placed on clarifying the limitations of quantum algorithms, how they compare with their best classical counterparts and why quantum resources are expected to provide advantages for learning problems. Learning in the presence of noise and certain computationally hard problems in machine learning are identified as promising directions for the field. Practical questions, like how to upload classical data into quantum form, will also be addressed.Comment: v3 33 pages; typos corrected and references adde

    2015 Update on Acute Adverse Reactions to Gadolinium based Contrast Agents in Cardiovascular MR. Large Multi-National and Multi-Ethnical Population Experience With 37788 Patients From the EuroCMR Registry

    Get PDF
    Objectives: Specifically we aim to demonstrate that the results of our earlier safety data hold true in this much larger multi-national and multi-ethnical population. Background: We sought to re-evaluate the frequency, manifestations, and severity of acute adverse reactions associated with administration of several gadolinium- based contrast agents during routine CMR on a European level. Methods: Multi-centre, multi-national, and multi-ethnical registry with consecutive enrolment of patients in 57 European centres. Results: During the current observation 37788 doses of Gadolinium based contrast agent were administered to 37788 patients. The mean dose was 24.7 ml (range 5–80 ml), which is equivalent to 0.123 mmol/kg (range 0.01 - 0.3 mmol/kg). Forty-five acute adverse reactions due to contrast administration occurred (0.12 %). Most reactions were classified as mild (43 of 45) according to the American College of Radiology definition. The most frequent complaints following contrast administration were rashes and hives (15 of 45), followed by nausea (10 of 45) and flushes (10 of 45). The event rate ranged from 0.05 % (linear non-ionic agent gadodiamide) to 0.42 % (linear ionic agent gadobenate dimeglumine). Interestingly, we also found different event rates between the three main indications for CMR ranging from 0.05 % (risk stratification in suspected CAD) to 0.22 % (viability in known CAD). Conclusions: The current data indicate that the results of the earlier safety data hold true in this much larger multi-national and multi-ethnical population. Thus, the “off-label” use of Gadolinium based contrast in cardiovascular MR should be regarded as safe concerning the frequency, manifestation and severity of acute events

    Allozyme differentiation of two populations of the genus Neoplecostomus Eigenmann & Eigenmann, 1888 (Teleostei, Loricariidae) from the upper Paraná River basin, Brazil

    Get PDF
    Allozyme electrophoresis was used to examine 12 enzymatic systems in two populations of the genus Neoplecostomus from the Paraná River basin. Samples of Neoplecostomus sp. 1 were collected in Paraitinguinha stream of the Tietê River basin, in the municipality of Salesópolis, São Paulo State, and those of Neoplecostomus sp. 2 from São Domingos stream of the Rio Grande River basin, in the municipality of Muzambinho, Minas Gerais State. The genetic variability of the two populations was estimated by Nei’s expected heterozygosity and was considered lower than average for populations of freshwater fish. The proportion of polymorphic loci was low (only 5.26% for the locus Idh). The low frequency of heterozygosity for both populations revealed a high fixation of alleles for each locus. Homozygote excess was observed in both populations. The values of Nei’s genetic identity and the presence of loci with different allele frequencies in both populations may imply that the two populations belong to different species. The genetic variability between populations was compared to other data for loricariids

    A posterior epidural mass causing paraparesis in a 20-year-old healthy individual

    Get PDF
    We present a case of a posterior epidural abscess at the thoracic vertebral level causing paraparesia in a young, healthy individual with no otherwise predisposing factors, with normal laboratory findings, as diagnosed using fat-suppressed MR imaging. Spinal epidural abscess is a rare condition, encountered mostly in the midthoracic or lower lumbar vertebral levels of elderly patients, that has a high mortality and morbidity (18-31%) when diagnosis and treatment is delayed. It is rarely spontaneous and is usually accompanied by spinal osteomyelitis. Diagnosis is rather easy in cases of vertebral osteomyelitis or when classical clinical, laboratory and imaging findings are present. However, cases of spontaneous development, with no predisposing factors, and lack of abscess suggesting clinical and laboratory findings may be a diagnostic challenge. In such cases, other posterior epidural masses such as schwannoma, neurofibroma, meningioma and hematoma should be considered in the differential diagnosis. Both the clinician and the radiology physician should have a high suspicion of epidural abscesses, because their early diagnosis and treatment is important. In addition to routine MR images, fat-suppressed MR images prove helpful in the diagnosis of spontaneous epidural abscesses by showing the inflammatory changes in the paraspinal area

    Searching for Exoplanets Using a Microresonator Astrocomb

    Get PDF
    Detection of weak radial velocity shifts of host stars induced by orbiting planets is an important technique for discovering and characterizing planets beyond our solar system. Optical frequency combs enable calibration of stellar radial velocity shifts at levels required for detection of Earth analogs. A new chip-based device, the Kerr soliton microcomb, has properties ideal for ubiquitous application outside the lab and even in future space-borne instruments. Moreover, microcomb spectra are ideally suited for astronomical spectrograph calibration and eliminate filtering steps required by conventional mode-locked-laser frequency combs. Here, for the calibration of astronomical spectrographs, we demonstrate an atomic/molecular line-referenced, near-infrared soliton microcomb. Efforts to search for the known exoplanet HD 187123b were conducted at the Keck-II telescope as a first in-the-field demonstration of microcombs

    Biochemical comparison of two Hypostomus populations (Siluriformes, Loricariidae) from the Atlântico Stream of the upper Paraná River basin, Brazil

    Get PDF
    Two syntopic morphotypes of the genus Hypostomus - H. nigromaculatus and H. cf. nigromaculatus (Atlântico Stream, Paraná State) - were compared through the allozyme electrophoresis technique. Twelve enzymatic systems (AAT, ADH, EST, GCDH, G3PDH, GPI, IDH, LDH, MDH, ME, PGM and SOD) were analyzed, attributing the score of 20 loci, with a total of 30 alleles. Six loci were diagnostic (Aat-2, Gcdh-1, Gpi-A, Idh-1, Ldh-A and Mdh-A), indicating the presence of interjacent reproductive isolation. The occurrence of few polymorphic loci acknowledge two morphotypes, with heterozygosity values He = 0.0291 for H. nigromaculatus and He = 0.0346 for H. cf. nigromaculatus. FIS statistics demonstrated fixation of the alleles in the two morphotypes. Genetic identity (I) and distance (D) of Nei (1978) values were I = 0.6515 and D = 0.4285. The data indicate that these two morphotypes from the Atlântico Stream belong to different species

    Management of chronic lateral instability due to lateral collateral ligament deficiency after total knee arthroplasty: a case report

    Get PDF
    <p>Abstract</p> <p>Introduction</p> <p>Lateral instability following total knee arthroplasty (TKA) is a rare condition with limited report of treatment options. The objective of this case presentation is to demonstrate the outcomes of different surgical procedures performed in a single patient with lateral collateral ligament (LCL) deficiency.</p> <p>Case presentation</p> <p>We present a case of chronic lateral instability due to LCL deficiency after primary TKA in a 47-year-old Caucasian woman with an obesity problem. Multiple treatment options have been performed in order to manage this problem, including the following: ligament reconstruction; combined ligament reconstruction and constrained implant; and rotating-hinge knee prosthesis that was the most recent surgery. All ligament reconstruction procedures failed within one year. The varus-valgus constrained prosthesis provided stability for six years.</p> <p>Conclusions</p> <p>Ligament reconstruction alone cannot provide enough stability for the treatment of chronic lateral instability in patients with obesity problems and LCL deficiency. When the reconstruction fails, a salvage procedure with rotating-hinge knee is still available.</p

    QUBIC: The QU Bolometric Interferometer for Cosmology

    Get PDF
    One of the major challenges of modern cosmology is the detection of B-mode polarization anisotropies in the CMB. These originate from tensor fluctuations of the metric produced during the inflationary phase. Their detection would therefore constitute a major step towards understanding the primordial Universe. The expected level of these anisotropies is however so small that it requires a new generation of instruments with high sensitivity and extremely good control of systematic effects. We propose the QUBIC instrument based on the novel concept of bolometric interferometry, bringing together the sensitivity advantages of bolometric detectors with the systematics effects advantages of interferometry. Methods: The instrument will directly observe the sky through an array of entry horns whose signals will be combined together using an optical combiner. The whole set-up is located inside a cryostat. Polarization modulation will be achieved using a rotating half-wave plate and interference fringes will be imaged on two focal planes (separated by a polarizing grid) tiled with bolometers. We show that QUBIC can be considered as a synthetic imager, exactly similar to a usual imager but with a synthesized beam formed by the array of entry horns. Scanning the sky provides an additional modulation of the signal and improve the sky coverage shape. The usual techniques of map-making and power spectrum estimation can then be applied. We show that the sensitivity of such an instrument is comparable with that of an imager with the same number of horns. We anticipate a low level of beam-related systematics thanks to the fact that the synthesized beam is determined by the location of the primary horns. Other systematics should be under good control thanks to an autocalibration technique, specific to our concept, that will permit the accurate determination of most of the systematics parameters.Comment: 12 pages, 10 figures, submitted to Astronomy and Astrophysic
    corecore