32 research outputs found

    Tracionamento de incisivo central superior impactado com aparelho removível: relato de dois casos clínicos

    Get PDF
    An impacted tooth is defined as the one that presents, radiographically, two thirds of its root developed and doesn’t erupt naturally. When this condition is established in the anterior region, compromises the aesthetic appearance of the child, concerning the parents and encouraging the search for orthodontic treatment. The treatment can be done using different types of appliances, fixed or removable. Objective: the aim of this study was to report two clinical cases of impacted upper central incisor, which were treated using a removable appliance in the Orthodontic Department of the Faculty of Dentitry at the Federal University of Rio Grande do Sul. Case report: In both cases, the patients were male, in the mixed dentition and their chief complain was the absence of the central incisor. The treatment was performed through traction of the impacted incisors in both reported cases. The traction of the incisors was done using an upper removable appliance with a modified Hawley arch which was used to support the intermaxillary elastics that applied a force to extrude the incisors. Conclusion: the treatment for tooth impaction with traction supported by a removable appliance was successful, and as any kind of treatment has advantages and disadvantages. It is the duty of the general practitioner to select the best type of appliance for the case considering the particular characterists of each patient.Um dente impactado é definido como aquele que apresenta, radiograficamente, dois terços de sua raiz desenvolvida e não entra em processo eruptivo. Quando esta condição se estabelece na região anterior, compromete a aparência estética da criança, preocupando os pais e incentivando a procura por um tratamento ortodôntico. O tratamento pode ser feito através de diferentes aparatologias, fixas ou removíveis. Objetivo: relatar dois casos clínicos de tracionamento de incisivo central superior impactado com aparelho removível, os quais foram tratados na Disciplina de Ortodontia Clínica da FO UFRGS. Relato de caso: Em ambos os casos os pacientes eram do sexo masculino, encontravam-se em fase de dentição mista e buscaram atendimento tendo como queixa a ausência do incisivo central superior. O tratamento foi realizado através de tracionamento dos incisivos impactados em ambos os pacientes. O tracionamento foi realizado utilizando-se um aparelho removível superior com arco de Hawley modificado que foi usado como apoio para uso de elasticos intermaxilares que aplicavam força para fazer a extrusão dos incisivos. Conclusão: O protocolo de tratamento foi bem sucedido nos dois pacientes

    Temporomandibular disorders and Orthodontics : cross-sectional study with RDC/TMD application

    Get PDF
    Objetivo: Avaliar se o tratamento ortodôntico está associado à presença de desordens temporomandibulares (DTM) em adolescentes e adultos jovens de idade entre 12 e 24 anos. Materiais e métodos: Foi realizada uma investigação sobre sinais e sintomas de DTM aplicando-se o protocolo RDC/TMD (Critérios de Diagnóstico para Pesquisa das Desordens Temporomandibulares), em pacientes ortodônticos e controles. A amostra foi composta por 70 participantes divididos em dois grupos. O grupo ortodôntico foi composto por 35 voluntários em fase ativa de tratamento ortodôntico fixo e o controle por 35 voluntários sem histórico de tratamento ortodôntico. Resultados: Não ocorreram diferenças estatísticas entre os grupos relacionadas ao autorrelato de sintomas de dor de cabeça, dores na face, ruídos articulares e hábitos parafuncionais anteriores ao exame (p > 0,1). Em relação à abertura máxima de boca em milímetros e dor relacionada ao movimento mandibular de abertura também não houve diferença estatística entre os grupos (p > 0,3). No que se refere ao relato de dor à palpação nos músculos masseter e temporal, não ocorreram diferenças estatísticas entre os grupos (p > 0,5). Quanto ao exame das articulações temporomandibulares (ATM), os grupos não diferiram estatisticamente em relação ao relato de dor à palpação, nem quanto à presença de ruídos articulares (p > 0,4). Conclusões: O estudo sugere, portanto, que o uso de aparelho ortodôntico fixo não parece estar associado à presença ou ausência de desordens temporomandibulares em adolescentes e adultos jovens. É recomendável, no entanto, que estudos longitudinais sejam conduzidos aplicando-se o protocolo RDC/TMDObjective: To evaluate whether orthodontic treatment is associated with the presence of temporomandibular disorders (TMD) in adolescents and young adults, aged between 12 and 24 years old. Materials and methods: An investigation about TMD signs and symptoms applying the RDC/TMD (Diagnostic Criteria for Research of Temporomandibular Disorders) protocol was performed. A sample of 70 subjects was divided into two groups, orthodontic and control patients. The orthodontic group was formed by 35 volunteers in the active phase of orthodontic treatment and the control group by 35 volunteers with no history of orthodontic treatment. Results: No statistical differences between the groups for self-report symptoms involving history of headache, pain on the face, joint sounds or parafunctional habits before the examinations (p > 0,1) was found. With respect to maximum mouth opening and pain related to mandibular movements, both did not present statistically significant differences. (p > 0,3). Concerning masseter and temporal muscle pain under palpation, there were no statistical differences between groups (p > 0,5). As for the examination of the temporomandibular joints (TMJ), both groups did not differ for the presence of pain on palpation, nor for the presence of joint sounds (p > 0,4). Conclusions: The study suggests that the use of orthodontic appliances appears not to be associated with the presence or absence of temporomandibular disorders in adolescents and young adults. Longitudinal studies by applying the RDC/TMD protocol are recommende

    Desordens temporomandibulares e Ortodontia: estudo transversal com aplicação do RDC/TMD

    Get PDF
    Objective: To evaluate whether orthodontic treatment is associated with the presence of temporo-mandibular disorders (TMD) in adolescents and young adults, aged between 12 and 24 years old. Materials and methods: An investigation about TMD signs and symptoms applying the RDC/TMD (Diagnostic Criteria for Research of Temporomandibular Disorders) protocol was performed. A sample of 70 subjects was divided into two groups, orthodontic and control patients. The orthodontic group was formed by 35 volunteers in the active phase of orthodontic treatment and the control group by 35 volunteers with no history of orthodontic treatment. Results: No statistical differences between the groups for self-report symptoms involving history of headache, pain on the face, joint sounds or parafunctional habits before the examinations (p > 0,1) was found. With respect to maximum mouth opening and pain related to mandibular movements, both did not present statistically significant differences. (p > 0,3). Concerning masseter and tem oral muscle pain under palpation, there were no statistical differences between groups (p > 0,5). As for the examination of the temporomandibular joints (TMJ), both groups did not differ for the presence of pain on palpation, nor for the presence of joint sounds (p > 0,4). Conclusions: The study suggests that the use of orthodontic appliances appears not to be associated with the presence or absence of temporomandibular disorders in adolescents and young adults. Longitudinal studies by applying the RDC/TMD protocol are recommended.Objetivo: Avaliar se o tratamento ortodôntico está associado à presença de desordens temporomandibulares (DTM) em adolescentes e adultos jovens de idade entre 12 e 24 anos. Materiais e métodos: Foi realizada uma investigação sobre sinais e sintomas de DTM aplicando-se o protocolo RDC/TMD (Critérios de Diagnóstico para Pesquisa das Desordens Temporomandibulares), em pacientes ortodônticos e controles. A amostra foi composta por 70 participantes divididos em dois grupos. O grupo ortodôntico foi composto por 35 voluntários em fase ativa de tratamento ortodôntico fixo e o controle por 35 voluntários sem histórico de tratamento ortodôntico. Resultados: Não ocorreram diferenças estatísticas entre os grupos relacionadas ao autorrelato de sintomas de dor de cabeça, dores na face, ruídos articulares e hábitos parafuncionais anteriores ao exame (p > 0,1). Em relação à abertura máxima de boca em milímetros e dor relacionada ao movimento mandibular de abertura também não houve diferença estatística entre os grupos (p > 0,3). No que se refere ao relato de dor à palpação nos músculos masseter e temporal, não ocorreram diferenças estatísticas entre os grupos (p > 0,5). Quanto ao exame das articulações temporomandibulares (ATM), os grupos não diferiram estatisticamente em relação ao relato de dor à palpação, nem quanto à presença de ruídos articulares (p > 0,4). Conclusões: O estudo sugere, portanto, que o uso de aparelho ortodôntico fixo não parece estar associado à presença ou ausência de desordens temporomandibulares em adolescentes e adultos jovens. É recomendável, no entanto, que estudos longitudinais sejam conduzidos aplicando-se o protocolo RDC/TMD

    Estudo dos efeitos da expansão rápida de maxila em pacientes com mordida cruzada posterior tratados com aparelhos de Haas e de Hyrax

    No full text
    A expansão rápida da maxila é um tratamento rotineiro dentro da prática ortodôntica, e temos disponíveis vários tipos de aparelhos que realizam a abertura da sutura palatina mediana. Os aparelhos ortodônticos mais utilizados para este tipo de tratamento são os expansores de Hyrax e de Haas. Com o objetivo de avaliar as alterações transversais e anatômicas, mudanças de perímetro e de comprimento de arco, alterações de área do palato, assim como inclinações dos dentes posteriores superiores e inferiores foi realizado este estudo que comparou o desempenho dos aparelhos expansores de Hyrax e de Haas. O grupo de pacientes que foi tratado com aparelho de Haas teve a reabsorção radicular dos incisivos centrais superiores avaliada através de radiografias periapicais. Material e métodos: trinta e duas (32) crianças com idade entre 7 e 11 anos, de ambos os gêneros, portadoras de mordida cruzada posterior uni ou bilateral foram divididas em dois grupos: Haas e Hyrax, combinando-se gênero e idade das mesmas nos diferentes grupos. O material para análise constituiu-se de dois pares de modelos de estudo de cada paciente, um realizado no início do tratamento e outro após a remoção do aparelho. Esses modelos foram digitalizados com coordenadas x, y, e z de cada ponto, e após calcularam-se as seguintes medidas: as distâncias intermolares e intercaninos, comprimento e perímetro dos arcos superior e inferior, inclinação dos molares e do processo alveolar. A variação anatômica de área e altura do palato foi avaliada através de moldagens de silicona dos palatos dos modelos de gesso antes e depois da expansão rápida de maxila. Estas moldagens foram seccionadas, escaneadas e medidas. Resultados: Tanto o tratamento com o aparelho Hyrax quanto com o Haas ocasionaram aumento das distâncias intermolares e intercaninos, sendo que o grupo Hyrax resultou em um maior aumento...Rapid maxillary expansion is routine treatment in orthodontic practice, and wehave several types of appliances that accomplish medium palatal suture opening. The orthodontic appliances more used for this type of treatment are Hyrax and Haas expanders. This study was done with the objective to evaluate transversal alterations, changes in perimeter and arch length, alterations in palatal area, as well as inclination changes of the buccal segments in the upper and lower arches. The patient group that was treated with the Haas expander had the upper central incisor root resorption evaluated through the use of periapical radiographs. Material and methods; thirty two (32) children with ages between 7 and 11 years, from both genders and with uni or bilateral posterior crossbites were divided into two groups: Haas and Hyrax, matching gender and age in both groups. Two sets of cast models from each patient were available, one taken in the beginning of treatment and another taken after expander removal. This casts were digitized with x, y and z coordinates for each point and the following measurements were calculated: inter-molar and inter-cuspid distances, arch length and perimeter, molar inclination and alveolar process inclination. The anatomical variation of the area and height of the palato was evaluated using silicon impressions of the cast models before and after maxillary expansion. This impressions were cut, scanned and measured. Results: both treatments with Hyrax and Haas resulted in increase of the inter-molar and inter-cuspid distances, and the Hyrax group presented a higher increase in these measurements. Upper and lower arch length measurements decreased for both groups, and arch perimeter didn't presented a statistically significant change for the Hyrax and Haas groups. The cuspid region area showed a higher increase in the Hyrax group whereas the first permanent molar region...(Complete abstract click electronic access below)Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES

    In vitro force delivery of nickel-titanium superelastic archwires in vertical displacement

    No full text
    OBJECTIVE: The purpose of this study was to evaluate the force delivered by different superlastic nickel-titanium wires during vertical displacement, in order to determine whether their stress release meets the criteria for constant and light forces that are usually accredited to these archwires. METHOD: Ten samples of 6 brands of 0.016-in archwires (Ormco, GAC, Morelli, TP, American Orthodontics e Rocky Mountain) were tested in a complete metal model using Dynalock brackets (3M Unitek&#8482;). In the canine position, there was a sliding bracket connected to a pole. This set was related to a load cell of 0.5 kg attached to a universal testing machine (Autograph AG-199kNG, Shimadzu). The crosshead speed was 0.5 mm/min and the maximum displacement was 1.0 mm. The model was submerged in temperature-controlled water. The results were analyzed by ANOVA (p < 0.05), using the software SAS System 8.02, Cry, NC, USA. RESULTS: The TP archwire had the lowest force throughout the test, although the final force was high (277.91 g). The Rocky Mountain archwire had the highest force release (455.41 g). CONCLUSION: The different brands of wires tested in this study failed in delivering low and constant forces as expected from superlastic nickel-titanium wires. The forces were extremely heavy for a vertical tooth movement.<br>OBJETIVO: o objetivo deste estudo foi avaliar a força liberada por diferentes fios de níquel-titânio (NiTi) superelástico em deslocamento vertical, a fim de determinar se a liberação de estresse por esses satisfaz o critério de forças suaves e constantes, geralmente atribuído a tais arcos. MÉTODOS: dez amostras de seis arcos de NiTi superelástico 0,016” de marcas comerciais diferentes (Ormco, GAC, Morelli, TP, American Orthodontics e Rocky Mountain) foram testados em um modelo metálico usando braquetes Dynalock (3M Unitek). Na região do canino, havia um braquete móvel conectado a uma haste, a qual estava relacionada com uma célula de carga de 0,5kg de uma máquina universal de ensaios (Autograph AG-199kNG, Shimadzu). O deslocamento do conjunto na região do canino foi realizado a uma velocidade constante de 0,5mm/min e o deslocamento máximo foi de 1,0mm. O conjunto foi submerso em água com temperatura controlada a 37ºC. RESULTADOS: os resultados obtidos foram avaliados por ANOVA (p <0,05), usando o software SAS System 8.02, Cry, NC, EUA. O arco da TP apresentou a menor força durante todo o teste, embora a força final tenha sido elevada (277,91g). O fio da Rocky Mountain demonstrou a maior liberação de força (455,41g). CONCLUSÕES: conclui-se que todas as diferentes marcas comerciais testadas nesse estudo falharam em liberar forças baixas e constantes, como é esperado nos fios de níquel-titânio superelástico. As forças foram extremamente pesadas para o movimento vertical de dentes

    Liberação de força in vitro de fios de níquel-titânio superelásticos em deslocamento vertical

    No full text
    Objective: The purpose of this study was to evaluate the force delivered by different superlastic nickel-titanium wires during vertical displacement, in order to determine whether their stress release meets the criteria for constant and light forces that are usually accredited to these archwires. Method: Ten samples of 6 brands of 0.016-in archwires (Ormco, GAC, Morelli, TP, American Orthodontics e Rocky Mountain) were tested in a complete metal model using Dynalock brackets (3M Unitek™). In the canine position, there was a sliding bracket connected to a pole. This set was related to a load cell of 0.5 kg attached to a universal testing machine (Autograph AG-199kNG, Shimadzu). The crosshead speed was 0.5 mm/min and the maximum displacement was 1.0 mm. The model was submerged in temperature-controlled water. The results were analyzed by ANOVA (p < 0.05), using the software SAS System 8.02, Cry, NC, USA. Results: The TP archwire had the lowest force throughout the test, although the final force was high (277.91 g). The Rocky Mountain archwire had the highest force release (455.41 g). Conclusion: The different brands of wires tested in this study failed in delivering low and constant forces as expected from superlastic nickel-titanium wires. The forces were extremely heavy for a vertical tooth movement.Objetivo: o objetivo deste estudo foi avaliar a força liberada por diferentes fios de níquel-titânio (NiTi) superelástico em deslocamento vertical, a fim de determinar se a liberação de estresse por esses satisfaz o critério de forças suaves e constantes, geralmente atribuído a tais arcos. Métodos: dez amostras de seis arcos de NiTi superelástico 0,016” de marcas comerciais diferentes (Ormco, GAC, Morelli, TP, American Orthodontics e Rocky Mountain) foram testados em um modelo metálico usando braquetes Dynalock (3M Unitek). Na região do canino, havia um braquete móvel conectado a uma haste, a qual estava relacionada com uma célula de carga de 0,5kg de uma máquina universal de ensaios (Autograph AG-199kNG, Shimadzu). O deslocamento do conjunto na região do canino foi realizado a uma velocidade constante de 0,5mm/min e o deslocamento máximo foi de 1,0mm. O conjunto foi submerso em água com temperatura controlada a 37ºC. Resultados: os resultados obtidos foram avaliados por ANOVA (p <0,05), usando o software SAS System 8.02, Cry, NC, EUA. O arco da TP apresentou a menor força durante todo o teste, embora a força final tenha sido elevada (277,91g). O fio da Rocky Mountain demonstrou a maior liberação de força (455,41g). Conclusões: conclui-se que todas as diferentes marcas comerciais testadas nesse estudo falharam em liberar forças baixas e constantes, como é esperado nos fios de níquel-titânio superelástico. As forças foram extremamente pesadas para o movimento vertical de dentes

    Liberação de força in vitro de fios de níquel-titânio superelásticos em deslocamento vertical

    No full text
    Objective: The purpose of this study was to evaluate the force delivered by different superlastic nickel-titanium wires during vertical displacement, in order to determine whether their stress release meets the criteria for constant and light forces that are usually accredited to these archwires. Method: Ten samples of 6 brands of 0.016-in archwires (Ormco, GAC, Morelli, TP, American Orthodontics e Rocky Mountain) were tested in a complete metal model using Dynalock brackets (3M Unitek™). In the canine position, there was a sliding bracket connected to a pole. This set was related to a load cell of 0.5 kg attached to a universal testing machine (Autograph AG-199kNG, Shimadzu). The crosshead speed was 0.5 mm/min and the maximum displacement was 1.0 mm. The model was submerged in temperature-controlled water. The results were analyzed by ANOVA (p < 0.05), using the software SAS System 8.02, Cry, NC, USA. Results: The TP archwire had the lowest force throughout the test, although the final force was high (277.91 g). The Rocky Mountain archwire had the highest force release (455.41 g). Conclusion: The different brands of wires tested in this study failed in delivering low and constant forces as expected from superlastic nickel-titanium wires. The forces were extremely heavy for a vertical tooth movement.Objetivo: o objetivo deste estudo foi avaliar a força liberada por diferentes fios de níquel-titânio (NiTi) superelástico em deslocamento vertical, a fim de determinar se a liberação de estresse por esses satisfaz o critério de forças suaves e constantes, geralmente atribuído a tais arcos. Métodos: dez amostras de seis arcos de NiTi superelástico 0,016” de marcas comerciais diferentes (Ormco, GAC, Morelli, TP, American Orthodontics e Rocky Mountain) foram testados em um modelo metálico usando braquetes Dynalock (3M Unitek). Na região do canino, havia um braquete móvel conectado a uma haste, a qual estava relacionada com uma célula de carga de 0,5kg de uma máquina universal de ensaios (Autograph AG-199kNG, Shimadzu). O deslocamento do conjunto na região do canino foi realizado a uma velocidade constante de 0,5mm/min e o deslocamento máximo foi de 1,0mm. O conjunto foi submerso em água com temperatura controlada a 37ºC. Resultados: os resultados obtidos foram avaliados por ANOVA (p <0,05), usando o software SAS System 8.02, Cry, NC, EUA. O arco da TP apresentou a menor força durante todo o teste, embora a força final tenha sido elevada (277,91g). O fio da Rocky Mountain demonstrou a maior liberação de força (455,41g). Conclusões: conclui-se que todas as diferentes marcas comerciais testadas nesse estudo falharam em liberar forças baixas e constantes, como é esperado nos fios de níquel-titânio superelástico. As forças foram extremamente pesadas para o movimento vertical de dentes
    corecore