8 research outputs found
Development and implementation of real-time web-based dashboards in a multisite transfusion service
Background: In hospital transfusion services, visualization of blood product inventory in the form of web-based dashboards has the potential to improve the workflow and efficiency of blood product inventory management. While off-the-shelf “business intelligence” solutions by external vendors may offer the ability to display and analyze blood bank inventory data, laboratories may lack resources to readily access this technology. Using in-house talent, our transfusion service developed real-time, web-based dashboards to replace manual processes for managing both blood product inventory and cooler tracking at two large academic hospital blood banks. Methods: Dashboards were developed using Hypertext Markup Language, Cascading Style Sheets, and Hypertext Preprocessor scripting/programming languages. Data are extracted in real time from Sunquest (v7.3) Laboratory Information Systems Database (InterSystems Cache) and are refreshed every 2 min. Data are hosted internally by our institution's web servers and are accessed on a webpage via Microsoft Group Policy shortcuts. Results: Dashboards were designed and implemented to provide a fully customizable, dynamic, and secure method of displaying blood product inventory and blood product cooler status. Transfusion service staff utilized dashboard data to maintain adequate blood product supply, modify blood product replacement orders to prevent excess inventory, and transfer short-dated blood products between our facilities to minimize wastage. Conclusions: Dashboard technology can be readily implemented at hospital transfusion services with minimal capital expenditure. The implementation of real-time web-based dashboards for blood product inventory and cooler management at our centers facilitated on-demand blood product monitoring and replaced a tedious, manual process with a user-friendly and intuitive electronic tool
Correction of murine hemophilia a by hematopoietic stem cell gene therapy
A serious complication of current protein replacement therapy for hemophilia A patients with coagulation factor VIII (FVIII) deficiency is the frequent development of anti-FVIII inhibitor antibodies that preclude therapeutic benefit from further treatment. Induction of tolerance by persistent high-level FVIII synthesis following transplantation with hematopoietic stem cells expressing a retrovirally-delivered FVIII transgene offers the possibility to permanently correct the disease. Here, we transplanted bone marrow cells transduced with an optimized MSCV-based FVIII oncoretroviral vector into immunocompetent hemophilia A mice that had been conditioned with a potentially lethal dose of irradiation (800 cGy), a sublethal dose of irradiation (550 cGy) or a nonmyelablative preparative regimen involving busulfan. Therapeutic levels of FVIII (42%, 18% and 11% of normal, respectively) were detected in the plasma of the transplant recipients for the duration of the study (over 6 months). Moreover, subsequent challenge with recombinant FVIII elicited at most a minor anti-FVIII inhibitor antibody response in any of the experimental animals in contrast to the vigorous neutralizing humoral reaction to FVIII that was stimulated in naive hemophilia A mice. These findings represent an encouraging advance toward potential clinical application and long-term amelioration or cure of this progressively debilitating, life-threatening bleeding disorder
Recommended from our members
Investigating Transfusion-related Sepsis Using Culture-Independent Metagenomic Sequencing.
BackgroundTransfusion-related sepsis remains an important hospital infection control challenge. Investigation of septic transfusion events is often restricted by the limitations of bacterial culture in terms of time requirements and low yield in the setting of prior antibiotic administration.MethodsIn 3 gram-negative septic transfusion cases, we performed metagenomic next-generation sequencing (mNGS) of direct clinical blood specimens in addition to standard culture-based approaches utilized for infection control investigations. Pathogen detection leveraged IDSeq, a new open-access microbial bioinformatics portal. Phylogenetic analysis was performed to assess microbial genetic relatedness and understand transmission events.ResultsmNGS of direct clinical blood specimens afforded precision detection of pathogens responsible for each case of transfusion-related sepsis and enabled discovery of a novel Acinetobacter species in a platelet product that had become contaminated despite photochemical pathogen reduction. In each case, longitudinal assessment of pathogen burden elucidated the temporal sequence of events associated with each transfusion-transmitted infection. We found that informative data could be obtained from culture-independent mNGS of residual platelet products and leftover blood specimens that were either unsuitable or unavailable for culture or that failed to grow due to prior antibiotic administration. We additionally developed methods to enhance accuracy for detecting transfusion-associated pathogens that share taxonomic similarity to contaminants commonly found in mNGS library preparations.ConclusionsCulture-independent mNGS of blood products afforded rapid and precise assessment of pathogen identity, abundance, and genetic relatedness. Together, these challenging cases demonstrated the potential for metagenomics to advance existing methods for investigating transfusion-transmitted infections
Efficient construction of producer cell lines for a SIN lentiviral vector for SCID-X1 gene therapy by concatemeric array transfection
Retroviral vectors containing internal promoters, chromatin insulators, and self-inactivating (SIN) long terminal repeats (LTRs) may have significantly reduced genotoxicity relative to the conventional retroviral vectors used in recent, otherwise successful clinical trials. Large-scale production of such vectors is problematic, however, as the introduction of SIN vectors into packaging cells cannot be accomplished with the traditional method of viral transduction. We have derived a set of packaging cell lines for HIV-based lentiviral vectors and developed a novel concatemeric array transfection technique for the introduction of SIN vector genomes devoid of enhancer and promoter sequences in the LTR. We used this method to derive a producer cell clone for a SIN lentiviral vector expressing green fluorescent protein, which when grown in a bioreactor generated more than 20 L of supernatant with titers above 107 transducing units (TU) per milliliter. Further refinement of our technique enabled the rapid generation of whole populations of stably transformed cells that produced similar titers. Finally, we describe the construction of an insulated, SIN lentiviral vector encoding the human interleukin 2 receptor common γ chain (IL2RG) gene and the efficient derivation of cloned producer cells that generate supernatants with titers greater than 5 × 107 TU/mL and that are suitable for use in a clinical trial for X-linked severe combined immunodeficiency (SCID-X1)
Recommended from our members
Sepsis Attributed to Bacterial Contamination of Platelets Associated with a Potential Common Source - Multiple States, 2018.
During May-October 2018, four patients from three states experienced sepsis after transfusion of apheresis platelets contaminated with Acinetobacter calcoaceticus-baumannii complex (ACBC) and Staphylococcus saprophyticus; one patient died. ACBC isolates from patients' blood, transfused platelet residuals, and two environmental samples were closely related by whole genome sequencing. S. saprophyticus isolates from two patients' blood, three transfused platelet residuals, and one hospital environmental sample formed two whole genome sequencing clusters. This whole genome sequencing analysis indicated a potential common source of bacterial contamination; investigation into the contamination source continues. All platelet donations were collected using apheresis cell separator machines and collection sets from the same manufacturer; two of three collection sets were from the same lot. One implicated platelet unit had been treated with pathogen-inactivation technology, and two had tested negative with a rapid bacterial detection device after negative primary culture. Because platelets are usually stored at room temperature, bacteria in contaminated platelet units can proliferate to clinically relevant levels by the time of transfusion. Clinicians should monitor for sepsis after platelet transfusions even after implementation of bacterial contamination mitigation strategies. Recognizing adverse transfusion reactions and reporting to the platelet supplier and hemovigilance systems is crucial for public health practitioners to detect and prevent sepsis associated with contaminated platelets