    Comparison of symmetrical hemodialysis catheters using computational fluid dynamics

    Get PDF
    Purpose: Symmetric-tip dialysis catheters have become alternative devices because of low access recirculation and ease of tip positioning. Flow characteristics of three symmetric catheters were compared based on computational fluid dynamics (CFD) as they relate to catheter function. Materials And Methods: In Palindrome, GlidePath, and VectorFloW catheters, a computational fluid dynamics based approach was used to assess W regions of flow separation, which are prone to thrombus development; (ii) shear-induced platelet activation potency; (iii) recirculation; and (iv) venous outflow deflection. A steady-state, laminar flow model simulated: catheter tip position within the superior vena cava. Catheter performance was investigated at high hemodialysis flow rate (400 mL/min). Blood was assumed as a Newtonian fluid. Results: Wide regions of flow separation downstream of the Palindrome side slot and close to the distal tip were observed in forward and reversed line configurations. Geometric asymmetry of the distal guide wire aperture of the GlidePath catheter produced the highest levels of inverted velocity flow when run in reversed configuration. The lowest mean shear-induced platelet activation was exhibited by GlidePath and VectorFloW catheters; the Palindrome catheter exhibited 152% higher overall platelet activation potency. All catheters were associated with a recirculation close to zero; the helically contoured lumens of the VectorFlow catheter produced the greatest amount of deflection of venous flow away from the arterial lumen. Conclusions: The VectorFlow catheter produced less shear-induced platelet activation than the Palindrome catheter and less flow separation than the Palindrome and GlidePath catheters irrespective of line configuration These findings have,potential implications for differences in thrombogenic risk during clinical performance of these catheters

    Mechanotransmission of haemodynamic forces by the endothelial glycocalyx in a full-scale arterial model

    Get PDF
    The glycocalyx has been identified as a key mechano-sensor of the shear forces exerted by streaming blood onto the vascular endothelial lining. Although the biochemical reaction to the blood flow has been extensively studied, the mechanism of transmission of the haemodynamic shear forces to the endothelial transmembrane anchoring structures and, consequently, to the subcellular elements in the cytoskeleton, is still not fully understood. Here we apply a multiscale approach to elucidate how haemodynamic shear forces are transmitted to the transmembrane anchors of endothelial cells. Wall shear stress time histories, as obtained from image-based computational haemodynamics models of a carotid bifurcation, are used as a load and a continuum model is applied to obtain the mechanical response of the glycocalyx all along the cardiac cycle. The main findings of this in silico study are that: (1) the forces transmitted to the transmembrane anchors are in the range of 1–10 pN, which is in the order of magnitude reported for the different conformational states of transmembrane mechanotranductors; (2) locally, the forces transmitted to the anchors of the glycocalyx structure can be markedly different from the near-wall haemodynamic shear forces both in amplitude and frequency content. The findings of this in silico approach warrant future studies focusing on the actual forces transmitted to the transmembrane mechanotransductors, which might outperform haemodynamic descriptors of disturbed shear as localizing factors of vascular disease.Peer ReviewedPostprint (author's final draft

    Mechanotransmission of haemodynamic forces by the endothelial glycocalyx in a full-scale arterial model

    Get PDF
    The glycocalyx has been identified as a key mechano-sensor of the shear forces exerted by streaming blood onto the vascular endothelial lining. Although the biochemical reaction to the blood flow has been extensively studied, the mechanism of transmission of the haemodynamic shear forces to the endothelial transmembrane anchoring structures and, consequently, to the subcellular elements in the cytoskeleton, is still not fully understood. Here we apply a multiscale approach to elucidate how haemodynamic shear forces are transmitted to the transmembrane anchors of endothelial cells. Wall shear stress time histories, as obtained from image-based computational haemodynamics models of a carotid bifurcation, are used as a load and a continuum model is applied to obtain the mechanical response of the glycocalyx all along the cardiac cycle. The main findings of this in silico study are that: (1) the forces transmitted to the transmembrane anchors are in the range of 1–10 pN, which is in the order of magnitude reported for the different conformational states of transmembrane mechanotranductors; (2) locally, the forces transmitted to the anchors of the glycocalyx structure can be markedly different from the near-wall haemodynamic shear forces both in amplitude and frequency content. The findings of this in silico approach warrant future studies focusing on the actual forces transmitted to the transmembrane mechanotransductors, which might outperform haemodynamic descriptors of disturbed shear as localizing factors of vascular disease.Peer ReviewedPostprint (author's final draft

    In silico biomechanical design of the metal frame of transcatheter aortic valves: multi-objective shape and cross-sectional size optimization

    Get PDF
    Transcatheter aortic valve (TAV) implantation has become an established alternative to open-hearth surgical valve replacement. Current research aims to improve the treatment safety and extend the range of eligible patients. In this regard, computational modeling is a valuable tool to address these challenges, supporting the design phase by evaluating and optimizing the mechanical performance of the implanted device. In this study, a computational framework is presented for the shape and cross-sectional size optimization of TAV frames. Finite element analyses of TAV implantation were performed in idealized aortic root models with and without calcifications, implementing a mesh-morphing procedure to parametrize the TAV frame. The pullout force magnitude, peak maximum principal stress within the aortic wall, and contact pressure in the left ventricular outflow tract were defined as objectives of the optimization problem to evaluate the device mechanical performance. Design of experiment coupled with surrogate modeling was used to define an approximate relationship between the objectives and the TAV frame parameters. Surrogate models were interrogated within a fixed design space and multi-objective design optimization was conducted. The investigation of the parameter combinations within the design space allowed the successful identification of optimized TAV frame geometries, suited to either a single or groups of aortic root anatomies. The optimization framework was efficient, resulting in TAV frame designs with improvedmechanical performance, ultimately leading to enhanced procedural outcomes and reduced costs associated with the device iterative development cycle
    • …