133 research outputs found

    Aero-Thermo-Dynamic Analysis of a Low Ballistic Coefficient Deployable Capsule in Earth Re-Entry

    Get PDF
    The paper deals with a microsatellite and the related deployable recovery capsule. The aero-brake is folded at launch and deployed in space and is able to perform a de-orbiting controlled re-entry. This kind of capsule, with a flexible, high temperature resistant fabric, thanks to its lightness and modulating capability, can be an alternative to the current “conventional” recovery capsules. The present authors already analyzed the trajectory and the aerodynamic behavior of low ballistic coefficient capsules during Earth re-entry and Mars entry. In previous studies, aerodynamic longitudinal stability analysis and evaluation of thermal and aerodynamic loads for a possible suborbital re-entry demonstrator were carried out in both continuum and rarefied regimes. The present study is aimed at providing preliminary information about thermal and aerodynamic loads and longitudinal stability for a similar deployable capsule, as well as information about the electronic composition of the plasma sheet and its possible influence on radio communications at the altitudes where GPS black-out could occur. Since the computer tests were carried out at high altitudes, therefore in rarefied flow fields, use of Direct Simulation Monte Carlo codes was mandatory. The computations involved both global aerodynamic quantities (drag and longitudinal moment coefficients) and local aerodynamic quantities (heat flux and pressure distributions along the capsule surface). The results verified that the capsule at high altitude (150 km) is self-stabilizing; it is stable around the nominal attitude or at zero angle of attack and unstable around the reverse attitude or at 180 deg angle of attack. The analysis also pointed out the presence of extra statically stable equilibrium trim points

    Leak-Tight Welding Experience from the Industrial Assembly of the LHC Cryostats at CERN

    Get PDF
    The assembly of the approximately 1700 LHC main ring cryostats at CERN involved extensive welding of cryogenic lines and vacuum vessels. More than 6 km of welding requiring leak tightness to a rate better than 1.10-9 mbar.l.s-1 on stainless steel and aluminium piping and envelopes was made, essentially by manual welding but also making use of orbital welding machines. In order to fulfil the safety regulations related to pressure vessels and to comply with the leak-tightness requirements of the vacuum systems of the machine, welds were executed according to high qualification standards and following a severe quality assurance plan. Leak detection by He mass spectrometry was extensively used. Neon leak detection was used successfully to locate leaks in the presence of helium backgrounds. This paper presents the quality assurance strategy adopted for welds and leak detection. It presents the statistics of non-conformities on welds and leaks detected throughout the entire production and the advances in the use of alternative leak detection methods in an industrial environment

    Influence of the elemental composition and crystal structure on the vacuum properties of Ti-Zr-V non-evaporable getter films

    Get PDF
    Non-evaporable thin film getters based on the elements of the 4th and 5th columns of the periodic table have been deposited by sputtering. Among the about 20 alloys studied to date, the lowest activation temperature (about 180 °C for a 24-hour heating) has been found for the Ti-Zr-V system in a well-defined composition range. The characterization of the activation behavior of such Ti-Zr-V films is presented. The evolution of the surface chemical composition during activation is monitored by Auger Electron Spectroscopy (AES) and the functional properties are evaluated by pumping speed measurements. The pumping speed characteristics are quite similar to those already measured for commercially available NEG materials, except for the much lower saturation coverage for CO. This inconvenience, which is due to the smooth surface structure of these films, can be counteracted by increasing the roughness of the substrate

    Vacuum properties of TiZrV non-evaporable getter films

    Get PDF
    Sputter-deposited thin films of TiZrV are fully activated after 24 h "in situ" heating at 180 °C. This activation temperature is the lowest of some 18 different getter coatings studied so far, and it allows the use of the getter thin film technology with aluminium alloy vacuum chambers, which cannot be baked at temperatures higher than 200 °C.An updated review is given of the most recent results obtained on TiZrV coatings, covering the following topics: influence of the elemental composition and crystal structure on activation temperature, discharge gas trapping and degassing, dependence of pumping speed and surface saturation capacity on film morphology, ageing consequent to activation-air venting cycles and ultimate pressures. Furthermore, the results obtained when exposing a coated particle beam chamber to synchrotron radiation in a real accelerator environment (ESRF Grenoble) are presented and discussed

    Periodic Bedrock Ridges at the ExoMars 2022 Landing Site: Evidence for a Changing Wind Regime

    Get PDF
    Wind-formed features are abundant in Oxia Planum (Mars), the landing site of the 2022 ExoMars mission, which shows geological evidence for a past wet environment. Studies of aeolian bedforms at the landing site were focused on assessing the risk for rover trafficability, however their potential in recording climatic fluctuations has not been explored. Here we show that the landing site experienced multiple climatic changes in the Amazonian, which are recorded by an intriguing set of ridges that we interpret as Periodic Bedrock Ridges (PBRs). Clues for a PBR origin result from ridge regularity, defect terminations, and the presence of preserved megaripples detaching from the PBRs. PBR orientation differs from superimposed transverse aeolian ridges pointing toward a major change in wind regime. Our results provide constrains on PBR formation mechanisms and offer indications on paleo winds that will be crucial for understanding the landing site geology

    Design and CFD Analysis of the Fluid Dynamic Sampling System of the “MicroMED” Optical Particle Counter

    Get PDF
    MicroMED is an optical particle counter that will be part of the ExoMars 2020 mission. Its goal is to provide the first ever in situ measurements of both size distribution and concentration of airborne Martian dust. The instrument samples Martian air, and it is based on an optical system that illuminates the sucked fluid by means of a collimated laser beam and detects embedded dust particles through their scattered light. By analyzing the scattered light profile, it is possible to obtain information about the dust grain size and speed. To do that, MicroMED’s fluid dynamic design should allow dust grains to cross the laser-illuminated sensing volume. The instrument’s Elegant Breadboard was previously developed and tested, and Computational Fluid Dynamic (CFD) analysis enabled determining its criticalities. The present work describes how the design criticalities were solved by means of a CFD simulation campaign. At the same time, it was possible to experimentally validate the results of the analysis. The updated design was then implemented to MicroMED’s Flight Model

    Martian environmental chamber: Dust system injection

    Get PDF
    NessunaThe aim of this work is to describe the development and implementation of an experimental setup able to reproduce some characteristics of the Martian atmosphere. The development of such setup fits into the context of MicroMED project, that foresees the development of an optical particle counter to be accommodated on the ExoMars 2020 Surface Platform, as part of the suite of sensors named Dust Complex. MicroMED will perform the first direct measurement of the size distribution of the powder close to Martian surface. The experimental setup is able to reproduce the characteristics of the Martian atmosphere: pressure, atmospheric composition, the actual temperature in which MicroMED will operate (from 20 C to 40 C) and the most important thing: the presence of suspended dust. The main result obtained in this work was the right configuration of an experimental setup in which to test sensors or instruments that work in Martian conditions. In particular, a dust injection system has been developed in order to obtain a dust distribution that was localized and without the formation of particles aggregates, for a correct calibration of the instrument

    CFD analysis and optimization of the sensor “MicroMED” for the ExoMars 2020 mission

    Get PDF
    Characterization of dust is a key aspect in recent space missions to Mars. Dust has a huge influence on the planet's global climate and it is always present in its atmosphere. MicroMED is an optical particle counter that will be part of the "Dust Complex" suite led by IKI in the ExoMars 2020 mission and it will determine size distribution and concentration of mineral grains suspended in martian atmosphere. A Computational Fluid Dynamic (CFD) analysis was performed aimed at the optimization of the instrument's sampling efficiency in the 0.4-20 ÎŒm diameter range of the dust particles. The analysis allowed to understand which conditions are optimum for operations on Mars and to consequently optimize the instrument's fluid dynamic design

    Discordant antibiotic therapy and length of stay in children hospitalized for urinary tract infection

    Full text link
    BACKGROUND: Urinary tract infections (UTIs) are a common reason for pediatric hospitalizations. OBJECTIVE: To determine the effect of discordant antibiotic therapy (in vitro nonsusceptibility of the uropathogen to initial antibiotic) on clinical outcomes for children hospitalized for UTI. DESIGN/SETTING: Multicenter retrospective cohort study in children aged 3 days to 18 years, hospitalized at 5 children's hospitals with a laboratory‐confirmed UTI. Data were obtained from medical records and the Pediatric Hospital Information System (PHIS) database. PARTICIPANTS: Patients with laboratory‐confirmed UTI. MAIN EXPOSURE: Discordant antibiotic therapy. MEASUREMENTS: Length of stay and fever duration. Covariates included age, sex, insurance, race, vesicoureteral reflux, antibiotic prophylaxis, genitourinary abnormality, and chronic care conditions. RESULTS: The median age of the 216 patients was 2.46 years (interquartile range [IQR]: 0.27, 8.89) and 25% were male. The most common causative organisms were E. coli and Klebsiella species. Discordant therapy occurred in 10% of cases and most commonly in cultures positive for Klebsiella species, Enterobacter species, and mixed organisms. In adjusted analyses, discordant therapy was associated with a 1.8 day (95% confidence interval [CI]: 1.5, 2.1) longer length of stay [LOS], but not with fever duration. CONCLUSIONS: Discordant antibiotic therapy for UTI is common and associated with longer hospitalizations. Further research is needed to understand the clinical factors contributing to the increased LOS and to inform decisions for empiric antibiotic selection in children with UTIs. Journal of Hospital Medicine 2012; © 2012 Society of Hospital MedicinePeer Reviewedhttp://deepblue.lib.umich.edu/bitstream/2027.42/94298/1/1960_ftp.pd
    • 

    corecore