7 research outputs found

    Comparison between passive knee kinematics during surgery and active knee kinematics during walking ::a preliminary study

    No full text
    Recovery of function is among a patient’s main expectations when undergoing total knee arthroplasty (TKA). However, normal gait knee function is not always completely restored, which can affect patient satisfaction and quality of life. Computer-assisted surgery (CAS) allows surgeons to evaluate passive knee kinematics intra-operatively. Understanding associations between knee kinematics measured during surgery and during daily activities, such as walking, could help define criteria for success based on knee function and not only on the correct alignment of the implant or the leg. This preliminary study compared passive knee kinematics measured during surgery with active kinematics measured during walking. Eight patients underwent a treadmill gait analysis using the KneeKG™ system both before surgery and three months afterwards. Knee kinematics were measured during CAS both before and after TKA implantation. The anatomical axes of the KneeKG™ and CAS systems were homogenised using a two-level, multi-body kinematics optimisation with a kinematic chain based on the calibration measured during CAS. A Bland–Altman analysis was performed before and after TKA for adduction–abduction angle, internal–external rotation, and anterior–posterior displacement over the whole gait cycle, at the single stance phase and at the swing phase. Homogenising the anatomical axes between CAS and treadmill gait led to limited median bias and limits of agreement (post-surgery -0.6 ± 3.6 deg, -2.7 ± 3.6 deg, and -0.2 ± 2.4 mm for adduction–abduction, internal–external rotation and anterior–posterior displacement, respectively). At the individual level, correlations between the two systems were mostly weak (R2 < 0.3) over the whole gait cycle, indicating low kinematic consistency between the two measurements. However, correlations were better at the phase level, especially the swing phase. The multiple sources of differences did not enable us to conclude whether they came from anatomical and biomechanical differences or from measurement system errors

    Clinical and objective gait outcomes remained stable seven years after total knee arthroplasty ::a prospective longitudinal study of 28 patients

    No full text
    Background : There is a paucity of data on mid to long-term gait outcomes after total knee arthroplasty. The aims of this longitudinal study were: to assess the evolution of both clinical and gait outcomes before and up to seven years after primary total knee arthroplasty (TKA) in a cohort of patients with knee osteoarthritis. Methods : This study included 28 patients evaluated before and up to seven years after primary TKA with both gait analysis and patient reported outcomes; of these, 20 patients were evaluated one year after surgery as well. Kinematic outcomes during gait (gait velocity, dimensionless gait veolicity, maximal knee flexion and knee range of motion), pain relief, Western Ontario and MacMaster Osteoarthritis Index (WOMAC), quality of life and patient satisfaction were assessed and compared at each visit with the paired Wilcoxon signed rank test (p < 0.05). Results : The significant improvement achieved at one year after TKA was stable up to seven years after surgery, with all clinical and kinematic outcomes unchanged, except for gait velocity, with a significant decrease over time (1.3 (1.1–1.4) m/s one year after TKA versus 1.0 (0.9–1.1) m/s, p < 0.05 up to seven years after). Conclusion : Patients with knee osteoarthritis significantly improve their clinical and kinematic outcomes at one year postoperatively and maintain the gain up to seven years after primary TKA, except for gait velocity which decreases over time, most likely along with ageing

    Prospective randomised study comparing screw versus helical blade in the treatment of low-energy trochanteric fractures

    No full text
    The purpose of this study was to compare femoral head placement, rates of reoperation and cephalic implant cut-out of a screw versus a blade for patients over age 60 with low energy trochanteric fractures (AO/OTA 31-A1, A2, and A3) treated either with sliding hip screw or cephalomedullary nail