170 research outputs found

    Cardiac Complication Following Subarachnoid Hemorrhage

    Get PDF
    Besides its severe neurological injuries, spontaneous subarachnoid hemorrhage (SAH) commonly causes cardiac complications. These complications could include three different aspects of cardiac diseases, that is, electrocardiographic abnormalities, myocardial injuries, and left ventricular dysfunction. These complications not only may lead to misdiagnosis of SAH as myocardial infarction, but also it may complicate the management of SAH. In this review, we described all cardiac complications during SAH and explained the appropriate monitoring and management of these problem

    Evaluation of effectiveness and safety of the CorPath GRX robotic system in endovascular embolization procedures of cerebral aneurysms.

    Get PDF
    BACKGROUND Robotic-assisted neurointervention was recently introduced, with implications that it could be used to treat neurovascular diseases. OBJECTIVE To evaluate the effectiveness and safety of the robotic-assisted platform CorPath GRX for treating cerebral aneurysms. METHODS This prospective, international, multicenter study enrolled patients with brain aneurysms that required endovascular coiling and/or stent-assisted coiling. The primary effectiveness endpoint was defined as successful completion of the robotic-assisted endovascular procedure without any unplanned conversion to manual treatment with guidewire or microcatheter navigation, embolization coil(s) or intracranial stent(s) deployment, or an inability to navigate vessel anatomy. The primary safety endpoint included intraprocedural and periprocedural events. RESULTS The study enrolled 117 patients (74.4% female) with mean age of 56.6 years from 10 international sites,. Headache was the most common presenting symptom in 40/117 (34.2%) subjects. Internal carotid artery was the most common location (34/122, 27.9%), and the mean aneurysm height and neck width were 5.7±2.6 mm and 3.5±1.4 mm, respectively. The overall procedure time was 117.3±47.3 min with 59.4±32.6 min robotic procedure time. Primary effectiveness was achieved in 110/117 (94%) subjects with seven subjects requiring conversion to manual for procedure completion. Only four primary safety events were recorded with two intraprocedural aneurysm ruptures and two strokes. A Raymond-Roy Classification Scale score of 1 was achieved in 71/110 (64.5%) subjects, and all subjects were discharged with a modified Rankin Scale score of ≤2. CONCLUSIONS This first-of-its-kind robotic-assisted neurovascular trial demonstrates the effectiveness and safety of the CorPath GRX System for endovascular embolization of cerebral aneurysm procedures. TRIAL REGISTRATION NUMBER NCT04236856

    Gadolinium-Enhanced Extracranial MRA Prior to Mechanical Thrombectomy Is Not Associated With an Improved Procedure Speed

    Get PDF
    Objectives: To assess whether performing a pre-intervention gadolinium-enhanced extracranial magnetic resonance angiogram (MRA) in addition to intracranial vascular imaging is associated with improved thrombectomy time metrics.Methods: Consecutive patients treated by MT at a large comprehensive stroke center between January 2012 and December 2017 who were screened using pre-intervention MRI were included. Patients characteristics and procedural data were collected. Univariate and multivariate analysis were performed to compare MT speed, efficacy, complications, and clinical outcomes between patients with and without pre-intervention gadolinium-enhanced extracranial MRA.Results: A total of 912 patients were treated within the study period, including 288 (31.6%) patients with and 624 (68.4%) patients without extracranial MRA. Multivariate analysis showed no significant difference between groups in groin puncture to clot contact time (RR = 0.93 [0.85–1.02], p = 0.14) or to recanalization time (RR = 0.92 [0.83–1.03], p = 0.15), rates of successful recanalization (defined as a mTICI 2b or 3, RR = 0.93 [0.62–1.42], p = 0.74), procedural complications (RR = 0.81 [0.51–1.27], p = 0.36), and good clinical outcome (defined by a mRS ≤ 2 at 3 months follow-up, RR = 1.05 [0.73–1.52], p = 0.79).Conclusion: Performing a pre-intervention gadolinium-enhanced extracranial MRA in addition to non-contrast intracranial MRA at stroke onset does not seem to be associated with a delay or shortening of procedure times

    Effect of extracranial lesion severity on outcome of endovascular thrombectomy in patients with anterior circulation tandem occlusion: analysis of the TITAN registry

    Get PDF
    Introduction Endovascular treatment (EVT) for tandem occlusion (TO) of the anterior circulation is complex but effective. The effect of extracranial internal carotid artery (EICA) lesion severity on the outcomes of EVT is unknown. In this study we investigated the effect of EICA lesion severity on the outcomes of tandem occlusion EVT. Methods A multicenter retrospective TITAN (Thrombectomy In TANdem lesions) study that included 18 international endovascular capable centers was performed. Patients who received EVT for atherosclerotic TO with or without EICA lesion intervention were included. Patients were divided into two groups based on the EICA lesion severity (high-grade stenosis (>= 90% North American Symptomatic Carotid Endarterectomy Trial) vs complete occlusion). Outcome measures included the 90-day clinical outcome (modified Rankin Scale score (mRS)), angiographic reperfusion (modified Thrombolysis In Cerebral Ischemia (mTICI) at the end of the procedure), procedural complications, and intracranial hemorrhage at 24 hours follow-up. Results A total of 305 patients were included in the study, of whom 135 had complete EICA occlusion and 170 had severe EICA stenosis. The EICA occlusion group had shorter mean onset-to-groin time (259 +/- 120 min vs 305 +/- 202 min;p=0.037), more patients with diabetes, and fewer with hyperlipidemia. With respect to the outcome, mTICI 2b-3 reperfusion was lower in the EICA occlusion group (70% vs 81%;p=0.03). The favorable outcome (90-day mRS 0-2), intracerebral hemorrhage and procedural complications were similar in both groups. Conclusion Atherosclerotic occlusion of the EICA in acute tandem strokes was associated with a lower rate of mTICI 2b-3 reperfusion but similar functional and safety outcomes when compared with high-grade EICA stenosis

    Time to treatment with bridging intravenous alteplase before endovascular treatment:subanalysis of the randomized controlled SWIFT-DIRECT trial.

    Get PDF
    BACKGROUND We hypothesized that treatment delays might be an effect modifier regarding risks and benefits of intravenous thrombolysis (IVT) before mechanical thrombectomy (MT). METHODS We used the dataset of the SWIFT-DIRECT trial, which randomized 408 patients to IVT+MT or MT alone. Potential interactions between assignment to IVT+MT and expected time from onset-to-needle (OTN) as well as expected time from door-to-needle (DTN) were included in regression models. The primary outcome was functional independence (modified Rankin Scale (mRS) 0-2) at 3 months. Secondary outcomes included mRS shift, mortality, recanalization rates, and (symptomatic) intracranial hemorrhage at 24 hours. RESULTS We included 408 patients (IVT+MT 207, MT 201, median age 72 years (IQR 64-81), 209 (51.2%) female). The expected median OTN and DTN were 142 min and 54 min in the IVT+MT group and 129 min and 51 min in the MT alone group. Overall, there was no significant interaction between OTN and bridging IVT assignment regarding either the functional (adjusted OR (aOR) 0.76, 95% CI 0.45 to 1.30) and safety outcomes or the recanalization rates. Analysis of in-hospital delays showed no significant interaction between DTN and bridging IVT assignment regarding the dichotomized functional outcome (aOR 0.48, 95% CI 0.14 to 1.62), but the shift and mortality analyses suggested a greater benefit of IVT when in-hospital delays were short. CONCLUSIONS We found no evidence that the effect of bridging IVT on functional independence is modified by overall or in-hospital treatment delays. Considering its low power, this subgroup analysis could have missed a clinically important effect, and exploratory analysis of secondary clinical outcomes indicated a potentially favorable effect of IVT with shorter in-hospital delays. Heterogeneity of the IVT effect size before MT should be further analyzed in individual patient meta-analysis of comparable trials. TRIAL REGISTRATION NUMBER URL: https://www. CLINICALTRIALS gov ; Unique identifier: NCT03192332

    Decline in subarachnoid haemorrhage volumes associated with the first wave of the COVID-19 pandemic

    Get PDF
    BACKGROUND: During the COVID-19 pandemic, decreased volumes of stroke admissions and mechanical thrombectomy were reported. The study\u27s objective was to examine whether subarachnoid haemorrhage (SAH) hospitalisations and ruptured aneurysm coiling interventions demonstrated similar declines. METHODS: We conducted a cross-sectional, retrospective, observational study across 6 continents, 37 countries and 140 comprehensive stroke centres. Patients with the diagnosis of SAH, aneurysmal SAH, ruptured aneurysm coiling interventions and COVID-19 were identified by prospective aneurysm databases or by International Classification of Diseases, 10th Revision, codes. The 3-month cumulative volume, monthly volumes for SAH hospitalisations and ruptured aneurysm coiling procedures were compared for the period before (1 year and immediately before) and during the pandemic, defined as 1 March-31 May 2020. The prior 1-year control period (1 March-31 May 2019) was obtained to account for seasonal variation. FINDINGS: There was a significant decline in SAH hospitalisations, with 2044 admissions in the 3 months immediately before and 1585 admissions during the pandemic, representing a relative decline of 22.5% (95% CI -24.3% to -20.7%, p\u3c0.0001). Embolisation of ruptured aneurysms declined with 1170-1035 procedures, respectively, representing an 11.5% (95%CI -13.5% to -9.8%, p=0.002) relative drop. Subgroup analysis was noted for aneurysmal SAH hospitalisation decline from 834 to 626 hospitalisations, a 24.9% relative decline (95% CI -28.0% to -22.1%, p\u3c0.0001). A relative increase in ruptured aneurysm coiling was noted in low coiling volume hospitals of 41.1% (95% CI 32.3% to 50.6%, p=0.008) despite a decrease in SAH admissions in this tertile. INTERPRETATION: There was a relative decrease in the volume of SAH hospitalisations, aneurysmal SAH hospitalisations and ruptured aneurysm embolisations during the COVID-19 pandemic. These findings in SAH are consistent with a decrease in other emergencies, such as stroke and myocardial infarction

    Augmentation du remplissage des anévrismes intracrâniens à l'aide de spirales en platine (études in vitro du taux de remplissage anévrismal, mesure des volumes anévrismaux in vitro et in vivo, applications et résultats cliniques)

    No full text
    Hypothèse: obtenir un remplissage important de l'anévrisme avec des coils permet de diminuer l'incidence de la recanalisation. Dans la première partie, nous avons utilisé différents types de coils afin de remplir des modèles in vitro d'anévrismes. Les coils "Souples " ont permis d'obtenir des taux de remplissage plus élevés que les coils " Standards ". De la même manière, les coils de formes " Complexes " ont permis d'obtenir des taux de remplissage plus élevés que les coils de forme " Hélicoïdale ". Par ailleurs, l'angiographie 3D (AR3D) s'est révélée plus exacte que l'angio scanner et l'angio IRM pour le calcul du volume anévrismal. Dans la deuxième partie, nous avons utilisé l'AR3D pour mesurer in vivo les volumes de 255 anévrismes. Le taux de remplissage n'est pas apparu comme un facteur déterminant quant à l'incidence de la recanalisation. A l'inverse, le volume de la lésion et la durée du suivi sont apparus comme les éléments déterminants de la survenue d'une recanalisation.Background: to fill an aneurysm with detachable platinum coils as much as possible ensure protection against further aneurysm recurrence. As a start, silicone sidewall aneurysm models were filled with various types of coils using conventional endovascular technique. Higher packing ratios (volume of inserted coils / volume of the aneurysm) were obtained with Soft coils when compared with Standard coils. As well, Complex-shaped coils provided with higher packing ratios than did Helicoidal coils. Moreover, 3D angiography was found to be more accurate than CT and MR angiographies in the determination of the aneurysm volume. Secondly, in the clinical setting, we used 3D angiography in 255 aneurysm volume measurements and calculation of packing ratios. High aneurysm packing ratios were not found to protect against aneurysm recurrence. Conversely, the aneurysm volume and the duration of angiographic follow-up were found to be statistically determinant factors of aneurysm recurrence.PARIS12-CRETEIL BU Multidisc. (940282102) / SudocSudocFranceF

    A VIRTUAL PROTOTYPING TOOL FOR KNITWEAR SIMULATION

    No full text
    International audienc

    The Barrel vascular reconstruction device for endovascular coiling of wide-necked intracranial aneurysms: a multicenter, prospective, post-marketing study

    No full text
    International audienceBackground and purpose The Barrel vascular reconstruction device (Barrel VRD) is a novel stent with design features that allow endovascular coiling of wide-necked bifurcation aneurysms while preserving adjacent branches, without necessitating dual stent implantation. This study aimed to assess the safety and effectiveness of the Barrel VRD at 12-month follow-up. Materials and methods The Barrel VRD trial is a prospective, multicenter, observational post-marketing registry evaluating the use of the Barrel VRD for treatment of wide-necked bifurcation aneurysms. The primary effectiveness endpoint was successful aneurysm treatment measured by digital subtraction angiography with a Raymond–Roy occlusion grade of 1 or 2 in the absence of retreatment, parent artery stenosis (>50%), or target aneurysm rupture at 12 months. The primary safety endpoint was the absence of neurological death or major stroke at 12 months. Results Twenty patients were enrolled from December 2013 to December 2014. The device was implanted in 19 patients with 19 aneurysms (8 middle cerebral artery, 4 anterior communicating artery, 1 internal carotid artery terminus, 4 basilar artery aneurysms; mean dome height 5.7±1.91 mm; mean neck length 4.8±1.35 mm, mean dome-to-neck ratio 1.6±2.0). Coiling was performed in all cases. The primary effectiveness endpoint was achieved in 78.9% of subjects (15/19; 12 complete occlusions, 3 neck remnants), and the primary safety endpoint was 5.3% (1/19). Conclusions This prospective study demonstrates that the Barrel VRD device resulted in ~80% occlusion rates and ~5% rates of neurological complications at 1 year after endovascular treatment of wide-necked bifurcation intracranial aneurysms. Registered clinical trial NCT02125097;Results

    Selective endovascular treatment of intracranial aneurysms with a liquid embolic: a single-center experience in 39 patients with 41 aneurysms.

    No full text
    Although embolization with detachable coils is an accepted alternative to surgical clipping, a major long-term problem is aneurysm recanalization due to coil compaction. Liquid embolic agents are a possible alternative as filling material that might decrease the recanalization rate. We evaluated the use of a liquid embolic for endovascular treatment of intracranial aneurysms.Case ReportsJournal Articleinfo:eu-repo/semantics/publishe
    corecore