1,137 research outputs found

    A new limit on the Ultra-High-Energy Cosmic-Ray flux with the Westerbork Synthesis Radio Telescope

    Get PDF
    A particle cascade (shower) in a dielectric, for example as initiated by an ultra-high energy cosmic ray, will have an excess of electrons which will emit coherent \v{C}erenkov radiation, known as the Askaryan effect. In this work we study the case in which such a particle shower occurs in a medium just below its surface. We show, for the first time, that the radiation transmitted through the surface is independent of the depth of the shower below the surface when observed from far away, apart from trivial absorption effects. As a direct application we use the recent results of the NuMoon project, where a limit on the neutrino flux for energies above 102210^{22}\,eV was set using the Westerbork Synthesis Radio Telescope by measuring pulsed radio emission from the Moon, to set a limit on the flux of ultra-high-energy cosmic rays.Comment: Accepted for publication in Phys. Rev.

    The Management of Pediatric Polytrauma: Review

    Get PDF
    Polytrauma is a major cause of mortality and morbidity in both developed and developing countries. The primary goal of this review is to provide a comprehensive overview on current knowledge in the management of pediatric polytrauma patients (PPPs). A database review was con- ducted based on a search in the Embase, Medline OVID-SP, Web of Science, Cochrane central, and Pubmed databases. Only studies with “paediatric population” and “polytrauma” as criteria were included. A total of 3310 citations were retrieved. Of these, 3271 were excluded after screening, based on title and abstract. The full texts of 39 articles were assessed; further selection left 25 articles to be included in this review. The most crucial point in the management of PPPs is preparedness of the staff and an emergency room furnished with age-appropriate drugs and equipment combined with a systemic approach

    An air shower array for LOFAR: LORA

    Get PDF
    LOFAR is a new form of radio telescope which can detect radio emission from air showers induced by very high-energy cosmic rays. It can also look for radio emission from particle cascades on the Moon induced by ultra high-energy cosmic rays or neutrinos. To complement the radio detection, we are setting up a small particle detector array LORA (LOfar Radboud Air shower array) within an area of 300\sim 300 m diameter in the LOFAR core. It will help in triggering and confirming the radio detection of air showers with the LOFAR antennas. In this paper, we present a short overview about LORA and discuss its current status.Comment: 10 pages (using article.cls), 6 figures, accepted for the proceedings of 22nd European Cosmic Ray Symposium, 3-6 August 2010, Finlan

    Quantifying antimicrobial resistance at veal calf farms

    Get PDF
    This study was performed to determine a sampling strategy to quantify the prevalence of antimicrobial resistance on veal calf farms, based on the variation in antimicrobial resistance within and between calves on five farms. Faecal samples from 50 healthy calves (10 calves/farm) were collected. From each individual sample and one pooled faecal sample per farm, 90 selected Escherichia coli isolates were tested for their resistance against 25 mg/L amoxicillin, 25 mg/L tetracycline, 0.5 mg/L cefotaxime, 0.125 mg/L ciprofloxacin and 8/152 mg/L trimethoprim/sulfamethoxazole (tmp/s) by replica plating. From each faecal sample another 10 selected E. coli isolates were tested for their resistance by broth microdilution as a reference. Logistic regression analysis was performed to compare the odds of testing an isolate resistant between both test methods (replica plating vs. broth microdilution) and to evaluate the effect of pooling faecal samples. Bootstrap analysis was used to investigate the precision of the estimated prevalence of resistance to each antimicrobial obtained by several simulated sampling strategies. Replica plating showed similar odds of E. coli isolates tested resistant compared to broth microdilution, except for ciprofloxacin (OR 0.29, p=0.05). Pooled samples showed in general lower odds of an isolate being resistant compared to individual samples, although these differences were not significant. Bootstrap analysis showed that within each antimicrobial the various compositions of a pooled sample provided consistent estimates for the mean proportion of resistant isolates. Sampling strategies should be based on the variation in resistance among isolates within faecal samples and between faecal samples, which may vary by antimicrobial. In our study, the optimal sampling strategy from the perspective of precision of the estimated levels of resistance and practicality consists of a pooled faecal sample from 20 individual animals, of which 90 isolates are tested for their susceptibility by replica plating

    The Scintillating Tail of Comet C/2020 F3 (Neowise)

    Full text link
    Context. The occultation of a radio source by the plasma tail of a comet can be used to probe structure and dynamics in the tail. Such occultations are rare, and the occurrence of scintillation, due to small-scale density variations in the tail, remains somewhat controversial. Aims. A detailed observation taken with the Low-Frequency Array (LOFAR) of a serendipitous occultation of the compact radio source 3C196 by the plasma tail of comet C/2020 F3 (Neowise) is presented. 3C196 tracked almost perpendicularly behind the tail, providing a unique profile cut only a short distance downstream from the cometary nucleus itself. Methods. Interplanetary scintillation (IPS) is observed as the rapid variation of the intensity received of a compact radio source due to density variations in the solar wind. IPS in the signal received from 3C196 was observed for five hours, covering the full transit behind the plasma tail of comet C/2020 F3 (Neowise) on 16 July 2020, and allowing an assessment of the solar wind in which the comet and its tail are embedded. Results. The results reveal a sudden and strong enhancement in scintillation which is unequivocally attributable to the plasma tail. The strongest scintillation is associated with the tail boundaries, weaker scintillation is seen within the tail, and previously-unreported periodic variations in scintillation are noted, possibly associated with individual filaments of plasma. Furthermore, contributions from the solar wind and comet tail are separated to measure a sharp decrease in the velocity of material within the tail, suggesting a steep velocity shear resulting in strong turbulence along the tail boundaryComment: Accepted for publication in Astronomy and Astrophysics, 8 pages, 9 figure

    Constraining the epoch of reionization with the variance statistic: simulations of the LOFAR case

    Get PDF
    Several experiments are underway to detect the cosmic redshifted 21-cm signal from neutral hydrogen from the Epoch of Reionization (EoR). Due to their very low signal-to-noise ratio, these observations aim for a statistical detection of the signal by measuring its power spectrum. We investigate the extraction of the variance of the signal as a first step towards detecting and constraining the global history of the EoR. Signal variance is the integral of the signal's power spectrum, and it is expected to be measured with a high significance. We demonstrate this through results from a simulation and parameter estimation pipeline developed for the Low Frequency Array (LOFAR)-EoR experiment. We show that LOFAR should be able to detect the EoR in 600 hours of integration using the variance statistic. Additionally, the redshift (zrz_r) and duration (Δz\Delta z) of reionization can be constrained assuming a parametrization. We use an EoR simulation of zr=7.68z_r = 7.68 and Δz=0.43\Delta z = 0.43 to test the pipeline. We are able to detect the simulated signal with a significance of 4 standard deviations and extract the EoR parameters as zr=7.720.18+0.37z_r = 7.72^{+0.37}_{-0.18} and Δz=0.530.23+0.12\Delta z = 0.53^{+0.12}_{-0.23} in 600 hours, assuming that systematic errors can be adequately controlled. We further show that the significance of detection and constraints on EoR parameters can be improved by measuring the cross-variance of the signal by cross-correlating consecutive redshift bins.Comment: 13 pages, 14 figures, Accepted for publication in MNRA

    Optimized Trigger for Ultra-High-Energy Cosmic-Ray and Neutrino Observations with the Low Frequency Radio Array

    Get PDF
    When an ultra-high energy neutrino or cosmic ray strikes the Lunar surface a radio-frequency pulse is emitted. We plan to use the LOFAR radio telescope to detect these pulses. In this work we propose an efficient trigger implementation for LOFAR optimized for the observation of short radio pulses.Comment: Submitted to Nuclear Instruments and Methods in Physics Research Section

    Assessing the impact of two independent direction-dependent calibration algorithms on the LOFAR 21-cm signal power spectrum

    Full text link
    Detecting the 21-cm signal from the Epoch of Reionisation (EoR) is challenging due to the strong astrophysical foregrounds, ionospheric effects, radio frequency interference and instrumental effects. Understanding and calibrating these effects are crucial for the detection. In this work, we introduce a newly developed direction-dependent (DD) calibration algorithm DDECAL and compare its performance with an existing algorithm, SAGECAL, in the context of the LOFAR-EoR 21-cm power spectrum experiment. In our data set, the North Celestial Pole (NCP) and its flanking fields were observed simultaneously. We analyse the NCP and one of its flanking fields. The NCP field is calibrated by the standard pipeline, using SAGECAL with an extensive sky model and 122 directions, and the flanking field is calibrated by DDECAL and SAGECAL with a simpler sky model and 22 directions. Additionally, two strategies are used for subtracting Cassiopeia A and Cygnus A. The results show that DDECAL performs better at subtracting sources in the primary beam region due to the application of a beam model, while SAGECAL performs better at subtracting Cassiopeia A and Cygnus A. This indicates that including a beam model during DD calibration significantly improves the performance. The benefit is obvious in the primary beam region. We also compare the 21-cm power spectra on two different fields. The results show that the flanking field produces better upper limits compared to the NCP in this particular observation. Despite the minor differences between DDECAL and SAGECAL due to the beam application, we find that the two algorithms yield comparable 21-cm power spectra on the LOFAR-EoR data after foreground removal. Hence, the current LOFAR-EoR 21-cm power spectrum limits are not likely to depend on the DD calibration method.Comment: 28 pages, 14 figures, accepted for publication in A&
    corecore