92 research outputs found

    Validation and data characteristics of methane and nitrous oxide profiles observed by MIPAS and processed with Version 4.61 algorithm

    Get PDF
    The ENVISAT validation programme for the atmospheric instruments MIPAS, SCIAMACHY and GOMOS is based on a number of balloon-borne, aircraft, satellite and ground-based correlative measurements. In particular the activities of validation scientists were coordinated by ESA within the ENVISAT Stratospheric Aircraft and Balloon Campaign or ESABC. As part of a series of similar papers on other species [this issue] and in parallel to the contribution of the individual validation teams, the present paper provides a synthesis of comparisons performed between MIPAS CH4 and N2O profiles produced by the current ESA operational software (Instrument Processing Facility version 4.61 or IPF v4.61, full resolution MIPAS data covering the period 9 July 2002 to 26 March 2004) and correlative measurements obtained from balloon and aircraft experiments as well as from satellite sensors or from ground-based instruments. In the middle stratosphere, no significant bias is observed between MIPAS and correlative measurements, and MIPAS is providing a very consistent and global picture of the distribution of CH4 and N2O in this region. In average, the MIPAS CH4 values show a small positive bias in the lower stratosphere of about 5%. A similar situation is observed for N2O with a positive bias of 4%. In the lower stratosphere/upper troposphere (UT/LS) the individual used MIPAS data version 4.61 still exhibits some unphysical oscillations in individual CH4 and N2O profiles caused by the processing algorithm (with almost no regularization). Taking these problems into account, the MIPAS CH4 and N2O profiles are behaving as expected from the internal error estimation of IPF v4.61 and the estimated errors of the correlative measurements

    Measurement of stratospheric HBr using high resolution far infrared spectroscopy

    Get PDF
    Far infrared spectral features of HBr have been observed in the stratospheric emission spectrum using a balloon borne high resolution Fourier transform spectrometer equipped with a high sensitivity detector specially designed for this purpose. The value of 1.6±0.6 parts per trillion in volume for the HBr mixing ratio has been retrieved, from the global‐fit analysis of 121 spectra, in the 25–36.5 km altitude range. The result is briefly compared with models and previous assessments

    Validation of MIPAS HNO3 operational data

    Get PDF
    Nitric acid (HNO3) is one of the key products that are operationally retrieved by the European Space Agency (ESA) from the emission spectra measured by the Michelson Interferometer for Passive Atmospheric Sounding (MIPAS) onboard ENVISAT. The product version 4.61/4.62 for the observation period between July 2002 and March 2004 is validated by comparisons with a number of independent observations from ground-based stations, aircraft/balloon campaigns, and satellites. Individual HNO3 profiles of the ESA MIPAS level-2 product show good agreement with those of MIPAS-B and MIPAS-STR (the balloon and aircraft version of MIPAS, respectively), and the balloon-borne infrared spectrometers MkIV and SPIRALE, mostly matching the reference data within the combined instrument error bars. In most cases differences between the correlative measurement pairs are less than 1 ppbv (5-10%) throughout the entire altitude range up to about 38 km (similar to 6 hPa), and below 0.5 ppbv (15-20% or more) above 30 km (similar to 17 hPa). However, differences up to 4 ppbv compared to MkIV have been found at high latitudes in December 2002 in the presence of polar stratospheric clouds. The degree of consistency is further largely affected by the temporal and spatial coincidence, and differences of 2 ppbv may be observed between 22 and 26 km (similar to 50 and 30 hPa) at high latitudes near the vortex boundary, due to large horizontal inhomogeneity of HNO3. Similar features are also observed in the mean differences of the MIPAS ESA HNO3 VMRs with respect to the ground-based FTIR measurements at five stations, aircraft-based SAFIRE-A and ASUR, and the balloon campaign IBEX. The mean relative differences between the MIPAS and FTIR HNO3 partial columns are within +/- 2%, comparable to the MIPAS systematic error of similar to 2%. For the vertical profiles, the biases between the MIPAS and FTIR data are generally below 10% in the altitudes of 10 to 30 km. The MIPAS and SAFIRE HNO3 data generally match within their total error bars for the mid and high latitude flights, despite the larger atmospheric inhomogeneities that characterize the measurement scenario at higher latitudes. The MIPAS and ASUR comparison reveals generally good agreements better than 10-13% at 20-34 km. The MIPAS and IBEX measurements agree reasonably well (mean relative differences within +/- 15%) between 17 and 32 km. Statistical comparisons of the MIPAS profiles correlated with those of Odin/SMR, ILAS-II, and ACE-FTS generally show good consistency. The mean differences averaged over individual latitude bands or all bands are within the combined instrument errors, and generally within 1, 0.5, and 0.3 ppbv between 10 and 40 km (similar to 260 and 4.5 hPa) for Odin/SMR, ILAS-II, and ACE-FTS, respectively. The standard deviations of the differences are between 1 to 2 ppbv. The standard deviations for the satellite comparisons and for almost all other comparisons are generally larger than the estimated measurement uncertainty. This is associated with the temporal and spatial coincidence error and the horizontal smoothing error which are not taken into account in our error budget. Both errors become large when the spatial variability of the target molecule is high.Peer reviewe

    Stratospheric HBr concentration profile obtained from far-infrared emission spectroscopy

    Get PDF
    Hydrogen bromide (HBr) is the principal bromine sink species for the ozone loss chemistry induced by bromine‐containing gases in the stratosphere. We report a 1994 balloon‐based measurement of the daytime stratospheric HBr profile between 20 and 36.5 km altitude. The average concentration result of 1.31±0.39 parts per trillion in volume (pptv) and an analysis for the concentration versus altitude profile are consistent with previously reported measurements. These results strengthen the evidence for a significantly higher HBr concentration than that predicted by current photochemical models which, on the basis of recent kinetics results, do not include significant HBr production by the reaction branch, BrO + HO2 → HBr + O3

    Special Issue (1989) - A.E.U. Quality tests

    No full text

    Temperature dependent impedance spectroscopy on poly-aniline based devices

    No full text
    International audienc

    Temperature dependent impedance spectroscopy on poly-aniline based devices

    No full text
    International audienc
    corecore