139 research outputs found

    A systematic review on neutrophils interactions with titanium and zirconia surfaces: Evidence from in vitro studies

    Get PDF
    Objectives: This systematic review aimed to assess in vitro studies that evaluated neutrophil interactions with different roughness levels in titanium and zirconia implant surfaces. Material and Methods: An electronic search for literature was conducted on PubMed, Embase, Scopus, and Web of Science and a total of 14 studies were included. Neutrophil responses were assessed based on adhesion, cell number, surface coverage, cell structure, cytokine secretion, reactive oxygen species (ROS) production, neutrophil activation, receptor expression, and neutrophil extracellular traps (NETs) release. The method of assessing the risk of bias was done using the toxicological data reliability assessment tool (TOXRTOOL). Results: Ten studies have identified a significant increase in neutrophil functions, such as surface coverage, cell adhesion, ROS production, and NETs released when interacting with rough titanium surfaces. Moreover, neutrophil interaction with rough–hydrophilic surfaces seems to produce less proinflammatory cytokines and ROS when compared to naive smooth and rough titanium surfaces. Regarding membrane receptor expression, two studies have reported that the FcγIII receptor (CD16) is responsible for initial neutrophil adhesion to hydrophilic titanium surfaces. Only one study compared neutrophil interaction with titanium alloy and zirconia toughened alumina surfaces and reported no significant differences in neutrophil cell count, activation, receptor expression, and death. Conclusions: There are not enough studies to conclude neutrophil interactions with titanium and zirconia surfaces. However, different topographic modifications such as roughness and hydrophilicity might influence neutrophil interactions with titanium implant surfaces

    Guidelines for the management of neuroendocrine tumours by the Brazilian gastrointestinal tumour group

    Get PDF
    Neuroendocrine tumours are a heterogeneous group of diseases with a significant variety of diagnostic tests and treatment modalities. Guidelines were developed by North American and European groups to recommend their best management. However, local particularities and relativisms found worldwide led us to create Brazilian guidelines. Our consensus considered the best feasible strategies in an environment involving more limited resources. We believe that our recommendations may be extended to other countries with similar economic standards.Univ Sao Paulo, Inst Canc Estado Sao Paulo, BR-01246000 Sao Paulo, BrazilUniv Sao Paulo, Fac Med, Dept Radiol & Oncol, BR-01246903 Sao Paulo, BrazilHosp Sirio Libanes, BR-01308050 Sao Paulo, BrazilHosp Moinhos de Vento Porto Alegre, BR-90035000 Porto Alegre, RS, BrazilOncoctr, BR-30360680 Belo Horizonte, MG, BrazilUniv Fed Rio Grande do Sul, Dept Cirurgia, BR-90040060 Porto Alegre, RS, BrazilHosp Clin Porto Alegre, BR-90035903 Porto Alegre, RS, BrazilUniv Fed Ceara, Fac Med, Dept Fisiol & Farmacol, BR-60020180 Fortaleza, Ceara, BrazilHosp Univ Walter Cantidio, BR-60430370 Fortaleza, Ceara, BrazilInst Nacl Canc, BR-20230240 Rio De Janeiro, BrazilUniv Sao Paulo, Fac Med, Disciplina Endocrinol & Metabol, BR-01246903 Sao Paulo, BrazilAC Camargo Canc Ctr, Dept Surg, BR-01509010 Sao Paulo, BrazilUniv Sao Paulo, Fac Med, Dept Gastroenterol, Sao Paulo, BrazilUniv Fed Ciencias Saude Porto Alegre, BR-90050170 Porto Alegre, RS, BrazilHosp Albert Einstein, BR-05652900 Sao Paulo, BrazilHosp Base, Fac Med Sao Jose do Rio Preto, BR-15090000 Sao Paulo, BrazilSanta Casa Sao Jose do Rio Preto, BR-15025500 Sao Jose Do Rio Preto, BrazilPontificia Univ Catolica Parana, Hosp Erasto Gaertner, BR-81520060 Curitiba, Parana, BrazilUniv Fed Rio Grande do Norte, BR-59300000 Natal, RN, BrazilUniv Sao Paulo, Inst Coracao, BR-05403900 Sao Paulo, BrazilAC Camargo Canc Ctr, Med Oncol, BR-01509010 Sao Paulo, BrazilUniv Fed Sao Paulo, Disciplina Gastroenterol, BR-04021001 Sao Paulo, BrazilHosp Sao Rafael, BR-41253190 Salvador, BA, BrazilHosp Canc Barretos, Dept Cirurgia Aparelho Digest Alto & Hepatobiliop, BR-14784400 Sao Paulo, BrazilUniv Sao Paulo, Fac Med, Dept Patol, BR-01246903 Sao Paulo, BrazilClin AMO, BR-1950640 Salvador, BA, BrazilHosp Sao Jose, BR-01323001 Sao Paulo, BrazilUniv Nove de Julho, BR-02111030 Sao Paulo, BrazilUniv Fed Sao Paulo, Disciplina Gastroenterol, BR-04021001 Sao Paulo, BrazilWeb of Scienc

    Measurement of the cosmic ray spectrum above 4×10184{\times}10^{18} eV using inclined events detected with the Pierre Auger Observatory

    Full text link
    A measurement of the cosmic-ray spectrum for energies exceeding 4×10184{\times}10^{18} eV is presented, which is based on the analysis of showers with zenith angles greater than 6060^{\circ} detected with the Pierre Auger Observatory between 1 January 2004 and 31 December 2013. The measured spectrum confirms a flux suppression at the highest energies. Above 5.3×10185.3{\times}10^{18} eV, the "ankle", the flux can be described by a power law EγE^{-\gamma} with index γ=2.70±0.02(stat)±0.1(sys)\gamma=2.70 \pm 0.02 \,\text{(stat)} \pm 0.1\,\text{(sys)} followed by a smooth suppression region. For the energy (EsE_\text{s}) at which the spectral flux has fallen to one-half of its extrapolated value in the absence of suppression, we find Es=(5.12±0.25(stat)1.2+1.0(sys))×1019E_\text{s}=(5.12\pm0.25\,\text{(stat)}^{+1.0}_{-1.2}\,\text{(sys)}){\times}10^{19} eV.Comment: Replaced with published version. Added journal reference and DO

    Energy Estimation of Cosmic Rays with the Engineering Radio Array of the Pierre Auger Observatory

    Full text link
    The Auger Engineering Radio Array (AERA) is part of the Pierre Auger Observatory and is used to detect the radio emission of cosmic-ray air showers. These observations are compared to the data of the surface detector stations of the Observatory, which provide well-calibrated information on the cosmic-ray energies and arrival directions. The response of the radio stations in the 30 to 80 MHz regime has been thoroughly calibrated to enable the reconstruction of the incoming electric field. For the latter, the energy deposit per area is determined from the radio pulses at each observer position and is interpolated using a two-dimensional function that takes into account signal asymmetries due to interference between the geomagnetic and charge-excess emission components. The spatial integral over the signal distribution gives a direct measurement of the energy transferred from the primary cosmic ray into radio emission in the AERA frequency range. We measure 15.8 MeV of radiation energy for a 1 EeV air shower arriving perpendicularly to the geomagnetic field. This radiation energy -- corrected for geometrical effects -- is used as a cosmic-ray energy estimator. Performing an absolute energy calibration against the surface-detector information, we observe that this radio-energy estimator scales quadratically with the cosmic-ray energy as expected for coherent emission. We find an energy resolution of the radio reconstruction of 22% for the data set and 17% for a high-quality subset containing only events with at least five radio stations with signal.Comment: Replaced with published version. Added journal reference and DO

    Measurement of the Radiation Energy in the Radio Signal of Extensive Air Showers as a Universal Estimator of Cosmic-Ray Energy

    Full text link
    We measure the energy emitted by extensive air showers in the form of radio emission in the frequency range from 30 to 80 MHz. Exploiting the accurate energy scale of the Pierre Auger Observatory, we obtain a radiation energy of 15.8 \pm 0.7 (stat) \pm 6.7 (sys) MeV for cosmic rays with an energy of 1 EeV arriving perpendicularly to a geomagnetic field of 0.24 G, scaling quadratically with the cosmic-ray energy. A comparison with predictions from state-of-the-art first-principle calculations shows agreement with our measurement. The radiation energy provides direct access to the calorimetric energy in the electromagnetic cascade of extensive air showers. Comparison with our result thus allows the direct calibration of any cosmic-ray radio detector against the well-established energy scale of the Pierre Auger Observatory.Comment: Replaced with published version. Added journal reference and DOI. Supplemental material in the ancillary file

    A Novel Tool for the Absolute End-to-End Calibration of Fluorescence Telescopes -The XY-Scanner

    Get PDF

    A new cross-check and review of aerosol attenuation measurements at the Pierre Auger Observatory

    Get PDF
    corecore