6 research outputs found

    Gain Enhancement of a Microstrip Patch Antenna Using a Reflecting Layer

    Get PDF
    A low profile, unidirectional, dual layer, and narrow bandwidth microstrip patch antenna is designed to resonate at 2.45 GHz. The proposed antenna is suitable for specific applications, such as security and military systems, which require a narrow bandwidth and a small antenna size. This work is mainly focused on increasing the gain as well as reducing the size of the unidirectional patch antenna. The proposed antenna is simulated and measured. According to the simulated and measured results, it is shown that the unidirectional antenna has a higher gain and a higher front to back ratio (F/B) than the bidirectional one. This is achieved by using a second flame retardant layer (FR-4), coated with an annealed copper of 0.035 mm at both sides, with an air gap of 0.04λ0 as a reflector. A gain of 5.2 dB with directivity of 7.6 dBi, F/B of 9.5 dB, and −18 dB return losses (S11) are achieved through the use of a dual substrate layer of FR-4 with a relative permittivity of 4.3 and a thickness of 1.6 mm. The proposed dual layer microstrip patch antenna has an impedance bandwidth of 2% and the designed antenna shows very low complexity during fabrication

    Implantable slot antenna with substrate integrated waveguide for biomedical applications

    Get PDF
    This work presents a new design of capsule slot antenna with substrate integrated waveguide (SIW) for wireless body area networks (WBANs) operating at the range of (2.5-4 GHz) which is located in the body area networks (BAN) standard in IEEE802.15.6. The proposed antenna was designed for WBANs. The substrate is assumed to be from Rogers 5880 with relative permittivity of 2.2, and thickness of 0.787 mm. The ground and the patch are created from annealed copper while the capsule is assumed to be a plastic material of medical grade polycarbonate. The antenna designed and summited using computer simulation technology (CST) software. A CST voxel model was used to study the performance of SIW capsule antenna and the ability of the band (2.5-4 GHz). Results indicated a wide bandwidth of 1.5 GHz between the range of (2.5-4) GHz at 3.3 GHz as center frequency, with return loss with more than -24.52 dB, a gain of -18.2 dB, voltage standing wave ratio (VSWR) of 1.17, and front-to-back ratio (FBR) of 10.07 dB. Through simulation, all considerable parameters associated with the proposed antenna including return loss, bandwidth, operating frequency, VSWR less than 2, radiation pattern were examined. Regarding size, gain, and frequency band, the proposed antenna is located with the standards of implantable medical devices (IMDs)

    Efficient Low-Complexity Digital Predistortion for Power Amplifier Linearization

    Get PDF
    In this paper, a low-complexity model is proposed for linearizing power amplifiers with memory effects using the digital predistortion (DPD) technique. In the proposed model, the linear, low-order nonlinear and high-order nonlinear memory effects are computed separately to provide flexibility in controlling the model parameters so that both high performance and low model complexity can be achieved. The performance of the proposed model is assessed based on experimental measurements of a commercial class AB power amplifier by applying a single-carrier wideband code division multiple access (WCDMA) signal. The linearity performance and the model complexity of the proposed model are compared with the memory polynomial (MP) model and the DPD with single-feedback model. The experimental results show that the proposed model outperforms the latter model by 5 dB in terms of adjacent channel leakage power ratio (ACLR) with comparable complexity. Compared to MP model, the proposed model shows improved ACLR performance by 10.8 dB with a reduction in the complexity by 17% in terms of number of floating-point operations (FLOPs) and 18% in terms of number of model coefficients

    Implantable slot antenna with substrate integrated waveguide for biomedical applications

    Get PDF
    This work presents a new design of capsule slot antenna with substrate integrated waveguide (SIW) for wireless body area networks (WBANs) operating at the range of (2.5-4 GHz) which is located in the body area networks (BAN) standard in IEEE802.15.6. The proposed antenna was designed for WBANs. The substrate is assumed to be from Rogers 5880 with relative permittivity of 2.2, and thickness of 0.787 mm. The ground and the patch are created from annealed copper while the capsule is assumed to be a plastic material of medical grade polycarbonate. The antenna designed and summited using computer simulation technology (CST) software. A CST voxel model was used to study the performance of SIW capsule antenna and the ability of the band (2.5-4 GHz). Results indicated a wide bandwidth of 1.5 GHz between the range of (2.5-4) GHz at 3.3 GHz as center frequency, with return loss with more than -24.52 dB, a gain of -18.2 dB, voltage standing wave ratio (VSWR) of 1.17, and front-to-back ratio (FBR) of 10.07 dB. Through simulation, all considerable parameters associated with the proposed antenna including return loss, bandwidth, operating frequency, VSWR less than 2, radiation pattern were examined. Regarding size, gain, and frequency band, the proposed antenna is located with the standards of implantable medical devices (IMDs)
    corecore