172 research outputs found

    Can verbal suggestions strengthen the effects of a relaxation intervention?

    Get PDF
    Short stress management interventions such as relaxation therapy have demonstrated preliminary effectiveness in reducing stress-related problems. A promising tool to strengthen the effectiveness of relaxation-based interventions is the use of verbal suggestions, as previous research provided evidence that verbal suggestions can induce positive outcome expectancies, facilitate adaptive responses to stress and improve health outcomes. The present experimental proof-of-concept study aimed to investigate the effects of a brief relaxation intervention and specifically the role of verbal suggestions on stress-related outcomes assessed by self-report questionnaires and psychophysiological data. 120 participants (mean age = 22.1 years) were randomized to one of four intervention conditions: a brief relaxation intervention plus verbal suggestions condition, a brief relaxation intervention only condition, a verbal suggestions only condition, and a control condition. Afterwards, participants were subjected to a psychosocial stress challenge to assess reactivity to a stressful event. Immediately after both relaxation interventions (with and without verbal suggestions), lower self-reported state anxiety was found compared to the control condition, but no differences were observed in response to the stressor. The verbal suggestions only condition did not impact state anxiety. No significant effects were found for verbal suggestion interventions on cortisol, alpha amylase, heart rate and skin conductance. This is the first study investigating the role of verbal suggestions in the effectiveness of a brief relaxation intervention. Although this experimental proof-of-concept study provides support for the effectiveness of a brief relaxation intervention in lowering state anxiety directly after the intervention, the effects did not impact the response to a subsequent stressor and we did not observe any evidence for the add-on effectiveness of verbal suggestions. The effectiveness of brief relaxation interventions on stress responses should be investigated further in future research by incorporating interventions that are tailored to the specific stress challenge and various types of verbal suggestions

    Can contagious itch be affected by positive and negative suggestions?

    Get PDF
    Contagious itch can be evoked by observing people scratching. Verbal suggestions about to-be-received itch can influence itch intensity, as shown by placebo research, but it is unknown whether this extends to contagious itch. The current study aimed to replicate prior findings that listening to scratching and rubbing sounds elicits contagious itch, and to investigate whether suggestions can modulate this process. Healthy participants (n= 140) received positive or negative suggestions about itch in response to the sounds (aimed to decrease or increase expected itch, respectively), or no specific suggestions as a control. Participants listened to a number of audio fragments with scratching and rubbing sounds. The amount of expected itch as well as itch sensation after each audio fragment were measured by self-report. Suggestions had no effect on the expected itch. Both rubbing and scratching sounds significantly elicited itch in all groups. Scratching sounds induced more itch than rubbing sounds exclusively in the control group. These findings indicate that short suggestions might be not effective enough to modify the expectations of people regarding contagious itch. Furthermore, suggestions modulate contagious itch to some degree, but not in the hypothesized direction. Potential similarities and differences in the neurobiological mechanisms of contagious itch and nocebo effects are discussed

    Technical errors and complications in orthopaedic trauma surgery

    Get PDF
    Introduction Adverse events and associated morbidity and subsequent costs receive increasing attention in clinical practice and research. As opposed to complications, errors are not described or analysed in literature on fracture surgery. The aim of this study was to provide a description of errors and complications in relation to fracture surgery, as well as the circumstances in which they occur, for example urgency, type of surgeon, and type of fracture. Methods All errors and complications were recorded prospectively in our hospital’s complication registry, which forms an integral part of the electronic medical patient file. All recorded errors and complications in the complication registry linked to fracture surgery between 1 January, 2000 and 31 December, 2010 were analysed. Results During the study period 4310 osteosynthesis procedures were performed. In 78 (1.8 %) procedures an error in osteosynthesis was registered. The number of procedures in which an error occurred was significantly lower (OR = 0.53; p = 0.007) when an orthopaedic trauma surgeon was part of the operating team. Of all 3758 patients who were admitted to the surgical ward for osteosynthesis, 745 (19.8 %) had one or more postoperative complications registered. There was no significant difference in the number of postoperative complications after osteosynthesis procedures in which an orthopaedic trauma surgeon was present or absent (16.7 vs. 19.1 %; p = 0.088; OR 0.85). Discussion In the present study the true error rate after osteosynthesis may have been higher than the rate found. Errors that had no significant consequence may be especially susceptible to underreporting. Conclusion The present study suggests that an osteosynthesis procedure performed by or actively assisted by an orthopaedic trauma surgeon decreases the probability of an error in osteosynthesis. Apart from errors in osteosynthesis, the involvement of an orthopaedic trauma surgeon did not lead to a significant reduction in the number of postoperative complications. Keywords: Fractures, Surgical error, Complication

    Placebo effects of open-label verbal suggestions on itch

    Get PDF
    Placebo effects are positive outcomes that are not due to active treatment components, which may be elicited even when patients are aware of receiving an inert substance (open-label). This proof-of-principle study investigated for the first time whether open-label placebo effects on itch can be induced by verbal suggestions alone. Ninety-two healthy volunteers were randomized to experimental (open-label suggestions) or control (no suggestions) groups. Self-reported itch evoked by histamine iontophoresis was the primary study outcome. In addition, itch expectations, skin condition and affect were assessed. The experimental group expected lower itch than the control group, which was, in turn, related to less experienced itch in this group only, although no significantly different itch levels were reported between groups. The results illustrate a potential role for open-label placebo effects in itch, and suggest that further study of verbal suggestions through an extensive explanation of placebo effects might be promising for clinical practice

    Computer-aided detection (CAD) for breast MRI: evaluation of efficacy at 3.0 T

    Get PDF
    OBJECTIVE: The purpose of the study was to evaluate the accuracy of 3.0-T breast MRI interpretation using manual and fully automated kinetic analyses. MATERIAL AND METHODS: Manual MRI interpretation was done on an Advantage Workstation. Retrospectively, all examinations were processed with a computer-aided detection (CAD) system. CAD data sets were interpreted by two experienced breast radiologists and two residents. For each lesion automated analysis of enhancement kinetics was evaluated at 50% and 100% thresholds. Forty-nine malignant and 22 benign lesions were evaluated. RESULTS: Using threshold enhancement alone, the sensitivity and specificity of CAD were 97.9% and 86.4%, respectively, for the 50% threshold, and 97.9% and 90%, respectively, for the 100% threshold. Manual interpretation by two breast radiologists showed a sensitivity of 84.6% and a specificity of 68.8%. For the same two radiologists the mean sensitivity and specificity for CAD-based interpretation was 90.4% (not significant) and 81.3% (significant at p < 0.05), respectively. With one-way ANOVA no significant differences were found between the two breast radiologists and the two residents together, or between any two readers separately. CONCLUSION: CAD-based analysis improved the specificity compared with manual analysis of enhancement. Automated analysis at 50% and 100% thresholds showed a high sensitivity and specificity for readers with varying levels of experience

    Variability in lutetium-177 SPECT quantification between different state-of-the-art SPECT/CT systems

    Get PDF
    Background: Quantitative SPECT imaging in targeted radionuclide therapy with lutetium-177 holds great potential for individualized treatment based on dose assessment. The establishment of dose-effect relations requires a standardized method for SPECT quantification. The purpose of this multi-center study is to evaluate quantitative accuracy and inter-system variations of different SPECT/CT systems with corresponding commercially available quantitative reconstruction algorithms. This is an important step towards a vendor-independent standard for quantitative lutetium-177 SPECT. Methods: Four state-of-the-art SPECT/CT systems were included: Discovery™ NM/CT 670Pro (GE Healthcare), Symbia Intevo™, and two Symbia™ T16 (Siemens Healthineers). Quantitative accuracy and inter-system variations were evaluated by repeatedly scanning a cylindrical phantom with 6 spherical inserts (0.5 – 113 ml). A sphere-to-background activity concentration ratio of 10:1 was used. Acquisition settings were standardized: medium energy collimator, body contour trajectory, photon energy window of 208 keV (± 10%), adjacent 20% lower scatter window, 2 × 64 projections, 128 × 128 matrix size, and 40 s projection time. Reconstructions were performed using GE Evolution with Q.Metrix™, Siemens xSPECT Quant™, Siemens Broad Quantification™ or Siemens Flash3D™ algorithms using vendor recommended settings. In addition, projection data were reconstructed using Hermes SUV SPECT™ with standardized reconstruction settings to obtain a vendor-neutral quantitative reconstruction for all systems. Volumes of interest (VOI) for the spheres were obtained by applying a 50% threshold of the sphere maximum voxel value corrected for background activity. For each sphere, the mean and maximum recovery coefficient (RCmean and RCmax) of three repeated measurements was calculated, defined as the imaged activity concentration divided by the actual activity concentration. Inter-system variations were defined as the range of RC over all systems. Re

    Adherence to a femoral neck fracture treatment guideline

    Get PDF
    Purpose: In 2007 the Dutch Surgical Society published a clinical practice guideline for the treatment of hip fracture patients, based on the best available international evidence at that time. We investigated to what extent treatment of femoral neck fracture patients in the Netherlands corresponded with these guidelines, and determined differences in patient characteristics between the treatment groups. Methods: All femoral neck fracture patients treated in 14 hospitals between February 2008 and August 2009 were included. Patient characteristics, X-rays, and treatment data were collected retrospectively. Results: From a total of 1,250 patients 59 % had been treated with arthroplasty, 39 % with internal fixation, and 2 % with a non-operative treatment. While 74 % of the treatment choices complied with the guideline, 12 % did not. In 14 % adherence could not be determined from the available data. Arthroplasty was preferred over internal fixation in elderly patients with severe comorbidity, pre-fracture osteoporosis and a displaced fracture, who were ambulatory with aids pre-fracture (odds ratio, OR 2.2-58.1). Sliding hip screws were preferred over cancellous screws in displaced fractures (OR 1.9). Conclusions: Overall guideline adherence was good. Most deviations concerned treatment of elderly patients with a displaced fracture and implant use in internal fixation. Additional data on these issues, preferably at a higher scientific level of evidence, is needed in order to improve the guideline and to reinforce a more uniform treatment of these patients
    • …
    corecore