526 research outputs found

    Inoculum selection influences the biochemical methane potential of agro-industrial substrates

    Get PDF
    Obtaining a reliable estimation of the methane potential of organic waste streams in anaerobic digestion, for which a biochemical methane potential (BMP) test is often used, is of high importance. Standardization of this BMP test is required to ensure inter-laboratory repeatability and accuracy of the BMP results. Therefore, guidelines were set out; yet, these do not provide sufficient information concerning origin of and the microbial community in the test inoculum. Here, the specific contribution of the methanogenic community on the BMP test results was evaluated. The biomethane potential of four different substrates (molasses, bio-refinery waste, liquid manure and high-rate activated sludge) was determined by means of four different inocula from full-scale anaerobic digestion plants. A significant effect of the selected inoculum on the BMP result was observed for two out of four substrates. This inoculum effect could be attributed to the abundance of methanogens and a potential inhibiting effect in the inoculum itself, demonstrating the importance of inoculum selection for BMP testing. We recommend the application of granular sludge as an inoculum, because of its higher methanogenic abundance and activity, and protection from bulk solutions, compared with other inocula

    Quantum noise in laser-interferometer gravitational-wave detectors with a heterodyne readout scheme

    Get PDF
    We analyze and discuss the quantum noise in signal-recycled laser interferometer gravitational-wave detectors, such as Advanced LIGO, using a heterodyne readout scheme and taking into account the optomechanical dynamics. Contrary to homodyne detection, a heterodyne readout scheme can simultaneously measure more than one quadrature of the output field, providing an additional way of optimizing the interferometer sensitivity, but at the price of additional noise. Our analysis provides the framework needed to evaluate whether a homodyne or heterodyne readout scheme is more optimal for second generation interferometers from an astrophysical point of view. As a more theoretical outcome of our analysis, we show that as a consequence of the Heisenberg uncertainty principle the heterodyne scheme cannot convert conventional interferometers into (broadband) quantum non-demolition interferometers.Comment: 16 pages, 8 figure

    Association of hydrophobically-modified poly(ethylene glycol) with fusogenic liposomes

    Get PDF
    AbstractWe present results on using cooperative interactions to shield liposomes by incorporating multiple hydrophobic anchoring sites on polyethylene glycol (PEG) polymers. The hydrophobically-modified PEGs (HMPEGs) are comb-graft polymers with strictly alternating monodisperse PEG blocks (Mw=6, 12, or 35 kDa) bonded to C18 stearylamide hydrophobes. Cooperativity is varied by changing the degree of oligomerization at a constant ratio of PEG to stearylamide. Fusogenic liposomes prepared from N-C12-DOPE:DOPC 7:3 (mol:mol) were equilibrated with HMPEGs. Affinity for polymer association to liposomes increases with the degree of oligomerization; equilibrium constants (given as surface coverage per equilibrium concentration of free polymer) for 6 kDa PEG increased from 6.1±0.8 (mg/m2)/(mg/ml) for 2.5 loops to 78.1±12.2 (mg/m2)/(mg/ml) for 13 loops. In contrast, the equilibrium constant for distearoylphosphatidylethanolamine-poly(ethylene glycol) (DSPE-PEG5k) was 0.4±0.1 (mg/m2)/(mg/ml).The multi-loop HMPEGs demonstrate higher levels of protection from complement binding than DSPE-PEG5k. Greater protection does not correlate with binding strength alone. The best shielding was by HMPEG6k-DP3 (with three 6 kDa PEG loops), suggesting that PEG chains with adequate surface mobility provide optimal protection from complement opsonization. Complement binding at 30 min and 12 h demonstrates that protection by multi-looped PEGs is constant whereas DSPE-PEG5k initially protects but presumably partitions off of the surface at longer times

    Phylogenetic analysis to define feline immunodeficiency virus subtypes in 31 domestic cats in South Africa

    Get PDF
    Feline immunodeficiency virus (FIV), a lentivirus, is an important pathogen of domestic cats around the world and has many similarities to human immunodeficiency virus (HIV). A characteristic of these lentiviruses is their extensive genetic diversity which has been an obstacle in the development of successful vaccines. Of the FIV genes, the envelope gene is the most variable and sequence differences in a portion of this gene have been used to define 5 FIV subtypes (A, B, C, D and E). In this study, the proviral DNA sequence of the V3-V5 region of the envelope gene was determined in blood samples from 31 FIV positive cats from 4 different regions of South Africa. Phylogenetic analysis demonstrated the presence of both subtypes A and C, with subtype A predominating. These findings contribute to the understanding of the genetic diversity of FI

    Techno-economic assessment at full scale of a biogas refinery plant receiving nitrogen rich feedstock and producing renewable energy and biobased fertilisers

    Get PDF
    Anaerobic digestion of nitrogen (N) rich substrates might be hindered when ammonia (NH3) formation reaches toxic levels for methanogenic microorganisms. One possible strategy to avoid inhibiting conditions is the removal of NH3 from digestate by stripping and scrubbing technology and by recirculating N depleted digestate back to the digester. This study aimed to i) monitor the performance (mass and energy balances) of a full scale digestate processing cascade that includes an innovative vacuum side stream NH3stripping and scrubbing system, ii) assess the production cost of ammonium sulphate (AS) solution and iii) evaluate its fertiliser quality. The use of gypsum to recover NH3 in the scrubbing unit, instead of the more common sulphuric acid, results in the generation of AS and a fertilising liming substrate. Mass and nutrient balances indicated that 57% and 7.5% of ammonium N contained in digestate was recovered in the form of a 22% AS and liming substrate, respectively. The energy balance showed that about 3.8 kWhel and 59 kWhth were necessary to recover 1 kg of N in the form of AS. Furthermore, the production cost of AS, including both capital and operational costs, resulted to be 5.8 € t−1 of digestate processed. According to the fertiliser quality assessment, this technology allows for the recovery of NH3in the form of salt solutions that can be utilised as a substitute for synthetic mineral nitrogen fertilisers.</p

    Sagnac Interferometer as a Speed-Meter-Type, Quantum-Nondemolition Gravitational-Wave Detector

    Full text link
    According to quantum measurement theory, "speed meters" -- devices that measure the momentum, or speed, of free test masses -- are immune to the standard quantum limit (SQL). It is shown that a Sagnac-interferometer gravitational-wave detector is a speed meter and therefore in principle it can beat the SQL by large amounts over a wide band of frequencies. It is shown, further, that, when one ignores optical losses, a signal-recycled Sagnac interferometer with Fabry-Perot arm cavities has precisely the same performance, for the same circulating light power, as the Michelson speed-meter interferometer recently invented and studied by P. Purdue and the author. The influence of optical losses is not studied, but it is plausible that they be fairly unimportant for the Sagnac, as for other speed meters. With squeezed vacuum (squeeze factor e2R=0.1e^{-2R} = 0.1) injected into its dark port, the recycled Sagnac can beat the SQL by a factor 103 \sqrt{10} \simeq 3 over the frequency band 10 {\rm Hz} \alt f \alt 150 {\rm Hz} using the same circulating power Ic820I_c\sim 820 kW as is used by the (quantum limited) second-generation Advanced LIGO interferometers -- if other noise sources are made sufficiently small. It is concluded that the Sagnac optical configuration, with signal recycling and squeezed-vacuum injection, is an attractive candidate for third-generation interferometric gravitational-wave detectors (LIGO-III and EURO).Comment: 12 pages, 6 figure

    Observing binary inspiral in gravitational radiation: One interferometer

    Get PDF
    We investigate the sensitivity of individual LIGO/VIRGO-like interferometers and the precision with which they can determine the characteristics of an inspiralling binary system. Since the two interferometers of the LIGO detector share nearly the same orientation, their joint sensitivity is similar to that of a single, more sensitive interferometer. We express our results for a single interferometer of both initial and advanced LIGO design, and also for the LIGO detector in the limit that its two interferometers share exactly the same orientation. We approximate the evolution of a binary system as driven exclusively by leading order quadrupole gravitational radiation. To assess the sensitivity, we calculate the rate at which sources are expected to be observed, the range to which they are observable, and the precision with which characteristic quantities describing the observed binary system can be determined. Assuming a conservative rate density for coalescing neutron star binary systems we expect that the advanced LIGO detector will observe approximately 69~yr1{}^{-1} with an amplitude SNR greater than 8. Of these, approximately 7~yr1{}^{-1} will be from binaries at distances greater than 950~Mpc. We explore the sensitivity of these results to a tunable parameter in the interferometer design (the recycling frequency). The optimum choice of the parameter is dependent on the goal of the observations, e.g., maximizing the rate of detections or maximizing the precision of measurement. We determine the optimum parameter values for these two cases.Comment: 40 pages (plus 7 figures), LaTeX/REVTEX3.0, NU-GR-

    Conserve Epitopes of Influenza Virus Induce Innate and Adaptive Immune Responses to Produce Specific Antibody Against M2e Protein

    Full text link
    The existing vaccines against influenza are based onthe generation of neutralizing antibody primarilydirected against surface protein, haemagglutinin(HA) and neuraminidase (NA). However, antigenicdrift and occasional shift of these two membraneglycoproteins, HA and NA, make vaccine productioncumbersome and necessitate yearly revision ofthe vaccine seed strains by the World HealthOrganization. For these reasons, many investigatorshave often tried to look at the possibility of generatinga universal vaccine useful against more than oneinfluenza strain. The objective of research was toobtain an alternative antigen as vaccine candidatefor universal flu vaccination, instead of HA and NAcomponents. In this study, we use conserved epitopeM2e which is consist of three major componentsuch as N-terminal M2e2-24 (24 amino acids),transmembrane(59 amino acids) and C-terminal (19amino acids). We design two components of antigen,linier and branched structures. The antigens thenformulated with aluminium hydroxide gel comparedto FCA/IFA adjuvant. These vaccines were testedtheir immunogenicity, and the potency to mature thedendritic cells for stimulating either CD8+ T cell orantibody-mediated immune responses. The antibodytitre and the maturity of dendritic cell indicated bycytokines concentration such as; IFN-ã, IL2 and IL4were measured by ELISA test.The result of researchshowed that the conserved epitope of Me2 2-16 whenincorporated with P25 protein from canine distempervirus (linear structure) in alhydrogel adjuvant hasgreater potential to produce anti-M2e antibodiesthan in Freund adjuvant. Alhydrogel adjuvant hada stronger effect than Freund adjuvant. Alhydrogelalso stimulate the release of IL-2 and IL-4

    Radiation-pressure cooling and optomechanical instability of a micro-mirror

    Get PDF
    Recent experimental progress in table-top experiments or gravitational-wave interferometers has enlightened the unique displacement sensitivity offered by optical interferometry. As the mirrors move in response to radiation pressure, higher power operation, though crucial for further sensitivity enhancement, will however increase quantum effects of radiation pressure, or even jeopardize the stable operation of the detuned cavities proposed for next-generation interferometers. The appearance of such optomechanical instabilities is the result of the nonlinear interplay between the motion of the mirrors and the optical field dynamics. In a detuned cavity indeed, the displacements of the mirror are coupled to intensity fluctuations, which modifies the effective dynamics of the mirror. Such "optical spring" effects have already been demonstrated on the mechanical damping of an electromagnetic waveguide with a moving wall, on the resonance frequency of a specially designed flexure oscillator, and through the optomechanical instability of a silica micro-toroidal resonator. We present here an experiment where a micro-mechanical resonator is used as a mirror in a very high-finesse optical cavity and its displacements monitored with an unprecedented sensitivity. By detuning the cavity, we have observed a drastic cooling of the micro-resonator by intracavity radiation pressure, down to an effective temperature of 10 K. We have also obtained an efficient heating for an opposite detuning, up to the observation of a radiation-pressure induced instability of the resonator. Further experimental progress and cryogenic operation may lead to the experimental observation of the quantum ground state of a mechanical resonator, either by passive or active cooling techniques
    corecore