897 research outputs found

    Fabrication of titanium multi-wall Thermal Protection System (TPS) test panel arrays

    Get PDF
    Several arrays were designed and tested. Tests included vibrational and acoustical tests, radiant heating tests, and thermal conductivity tests. A feasible manufacturing technique was established for producing the protection system panels

    Re-design and fabrication of titanium multi-wall Thermal Protection System (TPS) test panels

    Get PDF
    The Titanium Multi-wall Thermal Protection System (TIPS) panel was re-designed to incorporate Ti-6-2-4-2 outer sheets for the hot surface, ninety degree side closures for ease of construction and through panel fastness for ease of panel removal. Thermal and structural tests were performed to verify the design. Twenty-five panels were fabricated and delivered to NASA for evaluation at Langley Research Center and Johnson Space Center

    Surface excitonic emission and quenching effects in ZnO nanowire/nanowall systems: limiting effects on device potential.

    Get PDF
    We report ZnO nanowire/nanowall growth using a two-step vapour phase transport method on a-plane sapphire. X-ray diffraction and scanning electron microscopy data establish that the nanostructures are vertically well-aligned with c-axis normal to the substrate, and have a very low rocking curve width. Photoluminescence data at low temperatures demonstrate the exceptionally high optical quality of these structures, with intense emission and narrow bound exciton linewidths. We observe a high energy excitonic emission at low temperatures close to the band-edge which we assign to the surface exciton in ZnO at ~ 3.366 eV, the first time this feature has been reported in ZnO nanorod systems. This assignment is consistent with the large surface to volume ratio of the nanowire systems and indicates that this large ratio has a significant effect on the luminescence even at low temperatures. The band-edge intensity decays rapidly with increasing temperature compared to bulk single crystal material, indicating a strong temperature-activated non-radiative mechanism peculiar to the nanostructures. No evidence is seen of the free exciton emission due to exciton delocalisation in the nanostructures with increased temperature, unlike the behaviour in bulk material. The use of such nanostructures in room temperature optoelectronic devices appears to be dependent on the control or elimination of such surface effects

    Oocyte donation pregnancies-non-disclosure of oocyte recipient status to obstetric care providers and perinatal outcomes

    Get PDF
    Background: Oocyte donation pregnancies-non-disclosure of oocyte recipient (OR) status to obstetric care providers and perinatal outcomes. Many studies report a higher rate of pregnancy-induced hypertension (PIH) and severe pre-eclampsia (PET) in OR pregnancies. The objective is to determine the rates of non-disclosure of OR pregnancy to obstetric care providers and also the rates of perinatal complications. Method: This was a retrospective review of all oocyte recipient (OR) pregnancies, who subsequently delivered at Cork University Maternity Hospital, between 2007-2012 inclusive. Obstetric case notes were reviewed to investigate perinatal outcomes and whether OR status had been documented (unambiguously, in code or not at all). Results Less than one-third (30.2%; n=32/106) had unambiguous documentation, one-third (33%; n=35/106) had no documentation and the remainder (36.8%; n=39/106) had a code familiar only to their obstetrician. There was a high rate of gestational hypertensive disorders (28.3%; n= 30), most frequently occurring with multiple gestation. Conclusion There was a low rate of clear documentation of OR status. Gestational hypertensive disorders occurred with increased frequency

    How to Undertake a Clinically Relevant Systematic Review in a Rapidly Evolving Field: Magnetic Resonance Angiography

    Get PDF
    Objectives: The aim was to determine which generations of the evolving technology of magnetic resonance angiography (MRA) are currently of clinical relevance in two clinical applications. Our purpose was to plan a systematic review that would be valuable both to purchasers driven by cost-effectiveness and to practicing clinicians. Methods: Information was gathered from a search of major bibliographic databases, from a short questionnaire sent to 500 U.K. vascular radiologists and vascular surgeons, and from local clinical The authors thank A. Jackson and all those who completed a questionnaire. This work was carried out with the financial support of the Secretary of State for Health under the NHS Health Technology Assessment Programme, project 97/13/04. The views and opinions expressed do not necessarily reflect those of the Secretary of State for Health. In part, this work was undertaken by the Leeds Teaching Hospitals NHS Trust, which received funding from the NHS Executive. The views expressed in this publication are those of the authors and not necessarily those of the NHS Executive.experts. We asked which of the MRA techniques were currently used and, assuming availability, what would be their technique of choice. Results: There were 206 published articles that satisfied preliminary inclusion criteria: 69 discussed 2D time of flight (TOF); 47, 3D TOF; and 38, contrast-enhanced techniques. There were 162 questionnaires returned (60 radiologists, 102 surgeons). Of the total respondents, 77/162 (48%) used MRA in the assessment of carotid artery stenosis; 47/77 (61%) used 2D TOF; 32/77 (42%), 3D TOF; and 26/77 (34%), contrast-enhanced techniques. Thirty-five of 162 (22%) respondents used MRA in the assessment of peripheral vascular disease (PVD); 15/35 (43%) used 2D TOF, 4/35 (11%) used 3D TOF, and 22/35 (63%) used contrast-enhanced techniques. For those wishing to use MRA, contrast-enhanced techniques were the method of choice. Conclusions: The TOF methods that represent earlier generations of the technology remain clinically relevant, and will therefore be included in our systematic review. To ensure complete and relevant coverage in reviews of other evolving technologies, it would be advisable to obtain data for guidance in a similar way

    Use of magnetic resonance angiography to select candidates with recently symptomatic carotid stenosis for surgery: systematic review

    Get PDF
    Objective To determine if sufficient evidence exists to support the use of magnetic resonance angiography as a means of selecting patients with recently symptomatic high grade carotid stenosis for surgery. Design Systematic review of published research on the diagnostic performance of magnetic resonance angiography, 1990-9. Main outcome measures Performance characteristics of diagnostic test. Results 126 potentially relevant articles were identified, but many articles failed to examine die performance of magnetic resonance angiography as a diagnostic test at the surgical decision thresholds used in major clinical trials on endarterectomy. 26 articles were included in a meta-analysis that showed a maximal joint sensitivity and specificity of 99% (95% confidence interval 98% to 100%) for identifying 70-99% stenosis and 90% (81% to 99%) for identifying 50-99% stenosis. Only four articles evaluated contrast enhanced magnetic resonance angiography. Conclusions Magnetic resonance angiography is accurate for selecting patients for carotid endarterectomy at the surgical decision thresholds established in the major endarterectomy trials, but the evidence is not very robust because of the heterogeneity of the studies included. Research is to determine the diagnostic performance of the most recent developments in magnetic resonance angiography, including contrast enhanced techniques, as well as to assess the impact of magnetic resonance angiography on surgical decision making and outcomes

    Design and fabrication of titanium multi-wall Thermal Protection System (TPS) test panels

    Get PDF
    A titanium multiwall thermal protection system panel was designed. The panel is a nine sheet sandwich structure consisting of an upper and lower face sheet; four dimpled sheets, three septum sheets, and clips for attachment to a vehicle structure. An acceptable fabrication process was developed, and the panel design was verified through mechanical and thermal testing of component specimens. A design was completed which takes into consideration fabrication techniques, thermal properties, mechanical properties, and materials availability
    corecore