7,895 research outputs found

    Deployment mechanisms on Pioneer Venus probes

    Get PDF
    Deployment mechanisms were developed to position scientific instruments during probe descent into the Venus atmosphere. Each mechanism includes a provision for pyrotechnic release of the enclosure door, negator springs for positive deployment torque, and an active damper using a shunted dc motor. The deployment time requirement is under 2 seconds, and the deployment shock must be less than 100 g's. The mechanism is completely dry lubricated and constructed mainly of titanium for high strength and high temperature stability. The mechanism was qualified for descent decelerations up to 565 g's and for instrument alignment up to 940 F. The mechanism requirements, the hardware design details, the analytical simulations, and the qualification testing are described

    For knee pain, how predictive is physical examination for meniscal injury?

    Get PDF
    No single clinical examination element, or combination of such elements, reliably detects meniscal injury. The McMurray test is best for ruling in meniscal pathology. Assuming a 9% prevalence of meniscal tears among all knee injuries (a rate reflecting national primary care data), the posttest probability that a patient with McMurray's sign has a meniscal injury ranges from <30% to 63% (strength of recommendation [SOR]: B). In contrast, the absence of any positive physical examination findings effectively rules out meniscal pathology, yielding a posttest probability of 0.8% for lateral meniscus injury, 1.0% for medial meniscus injury, and 3.8% for any meniscal injury among primary care populations (SOR: B)

    Forward voltage short-pulse technique for measuring high power laser array junction temperature

    Get PDF
    The present invention relates to a method of measuring the temperature of the P-N junction within the light-emitting region of a quasi-continuous-wave or pulsed semiconductor laser diode device. A series of relatively short and low current monitor pulses are applied to the laser diode in the period between the main drive current pulses necessary to cause the semiconductor to lase. At the sufficiently low current level of the monitor pulses, the laser diode device does not lase and behaves similar to an electronic diode. The voltage across the laser diode resulting from each of these low current monitor pulses is measured with a high degree of precision. The junction temperature is then determined from the measured junction voltage using their known linear relationship

    SOURCE MEASUREMENT: DETERMINING THE RELEASE FROM A POINT SOURCE BY REMOTELY LOCATED SAMPLERS

    Full text link

    Attacking Group Protocols by Refuting Incorrect Inductive Conjectures

    Get PDF
    Automated tools for finding attacks on flawed security protocols often fail to deal adequately with group protocols. This is because the abstractions made to improve performance on fixed 2 or 3 party protocols either preclude the modelling of group protocols all together, or permit modelling only in a fixed scenario, which can prevent attacks from being discovered. This paper describes Coral, a tool for finding counterexamples to incorrect inductive conjectures, which we have used to model protocols for both group key agreement and group key management, without any restrictions on the scenario. We will show how we used Coral to discover 6 previously unknown attacks on 3 group protocols

    Qualification Testing of Laser Diode Pump Arrays for a Space-Based 2-micron Coherent Doppler Lidar

    Get PDF
    The 2-micron thulium and holmium-based lasers being considered as the transmitter source for space-based coherent Doppler lidar require high power laser diode pump arrays operating in a long pulse regime of about 1 msec. Operating laser diode arrays over such long pulses drastically impact their useful lifetime due to the excessive localized heating and substantial pulse-to-pulse thermal cycling of their active regions. This paper describes the long pulse performance of laser diode arrays and their critical thermal characteristics. A viable approach is then offered that allows for determining the optimum operational parameters leading to the maximum attainable lifetime

    Design and Use of Microphone Directional Arrays for Aeroacoustic Measurements

    Get PDF
    An overview of the development of two microphone directional arrays for aeroacoustic testing is presented. These arrays were specifically developed to measure airframe noise in the NASA Langley Quiet Flow Facility. A large aperture directional array using 35 flush-mounted microphones was constructed to obtain high resolution noise localization maps around airframe models. This array possesses a maximum diagonal aperture size of 34 inches. A unique logarithmic spiral layout design was chosen for the targeted frequency range of 2-30 kHz. Complementing the large array is a small aperture directional array, constructed to obtain spectra and directivity information from regions on the model. This array, possessing 33 microphones with a maximum diagonal aperture size of 7.76 inches, is easily moved about the model in elevation and azimuth. Custom microphone shading algorithms have been developed to provide a frequency- and position-invariant sensing area from 10-40 kHz with an overall targeted frequency range for the array of 5-60 kHz. Both arrays are employed in acoustic measurements of a 6 percent of full scale airframe model consisting of a main element NACA 632-215 wing section with a 30 percent chord half-span flap. Representative data obtained from these measurements is presented, along with details of the array calibration and data post-processing procedures

    Theoretical Evaluations of the Fission Cross Section of the 77 eV Isomer of 235-U

    Get PDF
    We have developed models of the fission barrier (barrier heights and transition state spectra) that reproduce reasonably well the measured fission cross section of 235^{235}U from neutron energy of 1 keV to 2 MeV. From these models we have calculated the fission cross section of the 77 eV isomer of 235^{235}U over the same energy range. We find that the ratio of the isomer cross section to that of the ground state lies between about 0.45 and 0.55 at low neutron energies. The cross sections become approximately equal above 1 MeV. The ratio of the neutron capture cross section to the fission cross section for the isomer is predicted to be about a factor of 3 larger for the isomer than for the ground state of 235^{235}U at keV neutron energies. We have also calculated the cross section for the population of the isomer by inelastic neutron scattering form the 235^{235}U ground state. We find that the isomer is strongly populated, and for En=1MeVE_n = 1 MeV the (n,nγ)(n,n'\gamma) cross section leading to the population of the isomer is of the order of 0.5 barn. Thus, neutron reaction network calculations involving the uranium isotopes in a high neutron fluence are likely to be affected by the 77 eV isomer of 235^{235}U. With these same models the fission cross sections of 233^{233}U and 237^{237}U can be reproduced approximately using only minor adjustments to the barrier heights. With the significant lowering of the outer barrier that is expected for the outer barrier the general behavior of the fission cross section of 239^{239}Pu can also be reproduced.Comment: 17 pages including 8 figure
    corecore