455 research outputs found

    Analysis of resonant responses of split ring resonators using conformal mapping techniques

    Get PDF
    We report a novel method for modeling the resonant frequency response of infra-red light, in the range of 2 to 10 microns, reflected from metallic spilt ring resonators (SRRs) fabricated on a silicon substrate. The calculated positions of the TM and TE peaks are determined from the plasma frequency associated with the filling fraction of the metal array and the equivalent LC circuit defined by the SRR elements. The capacitance of the equivalent circuit is calculated using conformal mapping techniques to determine the co-planar capacitance associated with both the individual and the neighbouring elements. The inductance of the equivalent circuit is based on the self-inductance of the individual elements and the mutual inductance of the neighboring elements. The results obtained from the method are in good agreement with experimental results and simulation results obtained from a commercial FDTD simulation software package. The method allows the frequency response of a SRR to be readily calculated without complex computational methods and enables new designs to be optimised for a particular frequency response by tuning the LC circuit

    Incorporating ex-vivo lung perfusion into the UK adult lung transplant service: an economic evaluation and decision analytic model

    Get PDF
    Background: An estimated 20–30% of end-stage lung disease patients awaiting lung transplant die whilst on the waiting list due to a shortage of suitable donor lungs. Ex-Vivo Lung Perfusion is a technique that reconditions donor lungs initially not deemed usable in order to make them suitable for transplantation, thereby increasing the donor pool. In this study, an economic evaluation was conducted as part of DEVELOP-UK, a multi-centre study assessing the clinical and cost-effectiveness of the Ex-Vivo Lung Perfusion technique in the United Kingdom. Methods: We estimated the cost-effectiveness of a UK adult lung transplant service combining both standard and Ex-Vivo Lung Perfusion transplants compared to a service including only standard lung transplants. A Markov model was developed and populated with a combination of DEVELOP-UK, published and clinical routine data, and extrapolated to a lifetime horizon. Probabilistic sensitivity and scenario analyses were used to explore uncertainty in the final outcomes. Results: Base-case model results estimated life years gained of 0.040, quality-adjusted life-years (QALYs) gained of 0.045 and an incremental cost per QALY of £90,000 for Ex-Vivo Lung Perfusion. Scenario analyses carried out suggest that an improved rate of converting unusable donor lungs using Ex-Vivo Lung Perfusion, similar resource use post-transplant for both standard and EVLP lung transplant and applying increased waiting list costs would reduce ICERs to approximately £30,000 or below. Conclusion: DEVELOP-UK base-case results suggest that incorporating Ex-Vivo Lung Perfusion into the UK adult lung transplant service is more effective, increasing the number of donor lungs available for transplant, but would not currently be considered cost-effective in the UK using the present NICE threshold. However, results were sensitive to change in some model parameters and in several plausible scenario analyses results indicate that a service incorporating Ex-vivo lung perfusion would be considered cost-effective . Trial registration: ISRCTN registry number: ISRCTN44922411. Date of registration: 06/02/2012. Retrospectively registered

    Optical modulation in a resonant tunneling relaxation oscillator

    Get PDF
    We report high-speed optical modulation in a resonant tunneling relaxation oscillator consisting of a resonant tunneling diode (RTD) integrated with a unipolar optical waveguide and incorporated in a package with a coplanar waveguide transmission line. When appropriately biased, the RTD can provide wide-bandwidth electrical gain. For wavelengths near the material band edge, small changes of the applied voltage give rise to large, high-speed electroabsorption modulation of the light. We have observed optical modulation at frequencies up to 14 GHz, associated with subharmonic injection locking of the RTD oscillation at the fundamental mode of the coplanar transmission line, as well as generation of 33 ps optical pulses due to relaxation oscillation

    Optical modulation at around 1550 nm in an InGaAlAs optical waveguide containing an InGaAs/AlAs resonant tunneling diode

    Get PDF
    We report electroabsorption modulation of light at around 1550 nm in a unipolar InGaAlAs optical waveguide containing an InGaAs/AlAs double-barrier resonant tunneling diode ~RTD!. The RTD peak-to-valley transition increases the electric field across the waveguide, which shifts the core material absorption band edge to longer wavelengths via the Franz–Keldysh effect, thus changing the light-guiding characteristics of the waveguide. Low-frequency characterization of a device shows modulation up to 28 dB at 1565 nm. When dc biased close to the negative differential conductance region, the RTD optical waveguide behaves as an electroabsorption modulator integrated with a wide bandwidth electrical amplifier, offering a potential advantage over conventional pn modulators

    Cotinine-assessed second-hand smoke exposure and risk of cardiovascular disease in older adults

    Get PDF
    Objectives: To examine whether second-hand smoke (SHS) exposure measured by serum cotinine is associated with increased coronary heart disease (CHD) and stroke risk among contemporary older British adults. Design: Prospective population-based study with self-reported medical history and health behaviours. Fasting blood samples were analysed for serum cotinine and cardiovascular disease (CVD) risk markers. Setting: Primary care centres in 25 British towns in 1998–2001. Patients: 8512 60–79-year-old men and women selected from primary care registers. Main outcome measures: Fatal and non-fatal myocardial infarction (MI; n=445) and stroke (n=386) during median 7.8-year follow-up. Main exposure: Observational study of serum cotinine assayed from fasting blood sample using liquid chromatography tandem mass spectrometry method, and self-reported smoking history. Results: Among 5374 non-smokers without pre-existing CVD, geometric mean cotinine was 0.15 ng/ml (IQR 0.05–0.30). Compared with non-smokers with cotinine ≤0.05 ng/ml, higher cotinine levels (0.06–0.19, 0.2–0.7 and 0.71–15.0 ng/ml) showed little association with MI; adjusted HRs were 0.92 (95% CI 0.63 to 1.35), 1.07 (0.73 to 1.55) and 1.09 (0.69 to 1.72), p(trend)=0.69. Equivalent HRs for stroke were 0.82 (0.55 to 1.23), 0.74 (0.48 to 1.13) and 0.69 (0.41 to 1.17), p(trend)=0.065. The adjustment for sociodemographic, behavioural and CVD risk factors had little effect on the results. The HR of MI for smokers (1–9 cigarettes/day) compared with non-smokers with cotinine ≤0.05 ng/ml was 2.14 (1.39 to 3.52) and 1.03 (0.52 to 2.04) for stroke. Conclusions: In contemporary older men and women, SHS exposure (predominantly at low levels) was not related to CHD or stroke risks, but we cannot rule out the possibility of modest effects at higher exposure levels

    Evaluating an extended rehabilitation service for stroke patients (EXTRAS): Study protocol for a randomised controlled trial

    Get PDF
    Background: Development of longer term stroke rehabilitation services is limited by lack of evidence of effectiveness for specific interventions and service models. We describe the protocol for a multicentre randomised controlled trial which is evaluating an extended stroke rehabilitation service. The extended service commences when routine 'organised stroke care' (stroke unit and early supported discharge (ESD)) ends. Methods/design: This study is a multicentre randomised controlled trial with health economic and process evaluations. It is set within NHS stroke services which provide ESD. Participants are adults who have experienced a new stroke (and carer if appropriate), discharged from hospital under the care of an ESD team. Discussion: The provision of longer term support for stroke survivors is currently limited. The results from this trial will inform future stroke service planning and configuration. Trial registration: This trial was registered with ISRCTN (identifier: ISRCTN45203373) on 9 August 2012

    Clinical effectiveness and cost-effectiveness of foot orthoses for people with established rheumatoid arthritis: an exploratory clinical trial

    Get PDF
    Objectives: Foot orthoses are commonly prescribed as an intervention for people with rheumatoid arthritis (RA). Data relating to the cost-effectiveness of foot orthoses in people with RA are limited. The aim was to evaluate the clinical and cost-effectiveness of two types of foot orthoses in people with established RA. Method: A single-blind randomized controlled trial was undertaken to compare custom-made foot orthoses (CMFOs) and simple insoles (SIs) in 41 people with established RA. The Foot Function Index (FFI) was used to measure foot pain, disability, and functional limitation. Costs were estimated from the perspective of the UK National Health Service (NHS), societal (patient and family) perspective, and secondary care resource use in terms of the intervention and staff time. Effects were assessed in terms of health gain expressed as quality-adjusted life years (QALYs). Results: At baseline, 20 participants received a CMFO and 21 participants received an SI. After 16 weeks foot pain improved in both the CMFOs (p = 0.000) and the SIs (p < 0.01). However, disability scores improved for CMFOs (p < 0.001) but not for SIs (p = 0.40). The cost-effectiveness results demonstrated no difference in cost between the arms (CMFOs: £159.10; SIs: £79.10; p = 0.35), with the CMFOs being less effective in terms of cost per QALY gain (p < 0.001). Conclusions: In people with established RA, semi-rigid customized foot orthoses can improve pain and disability scores in comparison to simple insoles. From a cost-effectiveness perspective, the customized foot orthoses were far more expensive to manufacture, with no significant cost per QALY gain
    corecore