17 research outputs found

    Gamma radiation survey of the LDEF spacecraft

    Get PDF
    The retrieval of the Long Duration Exposure Facility spacecraft in January 1990 after nearly six years in orbit offered a unique opportunity to study the long term buildup of induced radioactivity in the variety of materials on board. We conducted the first complete gamma-ray survey of a large spacecraft on LDEF shortly after its return to earth. A surprising observation was the Be-7 activity which was seen primarily on the leading edge of the satellite, implying that it was picked up by LDEF in orbit. This is the first known evidence for accretion of a radioactive isotope onto an orbiting spacecraft. Other isotopes observed during the survey, the strongest being Na-22, are all attributed to activation of spacecraft components. Be-7 is a spallation product of cosmic rays on nitrogen and oxygen in the upper atmosphere. However, the observed density is much greater than expected due to cosmic-ray production in situ. This implies transport of Be-7 from much lower altitudes up to the LDEF orbit

    ES2008-54271 Simulation, Analysis and Systems Engineering of a Hybrid-Electric Race Car

    Get PDF
    ABSTRACT For the past two years, Embry-Riddle has participated in the SAE Formula Hybrid competition. As part of the competition, a team of students analyze, design, and build a fully functional hybrid-electric race car. As an academic competition, the event is designed to allow a wide variety of system configurations and fuel choices. In order to optimize the vehicle characteristics, simulate vehicle performance, and build control laws, the design team created a Simulink model of the race car. As a recently created design competition, the SAE Formula Hybrid event offers an opportunity for both design innovation and system engineering. To develop a concept for the competition, the ERAU team developed detailed simulations of the vehicle in Simulink. Since the competition allows a variety of energy storage devices, engines, fuels, driveline configurations, and control systems, the development of a system dynamics model was not straight-forward. Further, system components for this project are constrained by some rules and practical constraints. The vehicle configuration was selected to be a parallel hybrid using a 250cc gasoline engine and 7.2kW DC motor with 1500F ultra-capacitor energy storage, with an unusual control strategy. The results of the Simulink model were used to predict how this vehicle configuration compares to other design choices including alternative fuels, energy storage devices and control strategies. The performance of the actual vehicle at the 2008 SAE Formula Hybrid competition, which occurs May 2008, will be presented at the conference

    Development and Characterization of a Round Hand-Held Silicon Photomultiplier Based Gamma Camera for Intraoperative Imaging

    No full text
    This paper describes the development of a hand-held gamma camera for intraoperative surgical guidance that is based on silicon photomultiplier (SiPM) technology. The camera incorporates a cerium doped lanthanum bromide (LaBr(3):Ce) plate scintillator, an array of 80 SiPM photodetectors and a two-layer parallel-hole collimator. The field of view is circular with a 60 mm diameter. The disk-shaped camera housing is 75 mm in diameter, approximately 40.5 mm thick and has a mass of only 1.4 kg, permitting either hand-held or arm-mounted use. All camera components are integrated on a mobile cart that allows easy transport. The camera was developed for use in surgical procedures including determination of the location and extent of primary carcinomas, detection of secondary lesions and sentinel lymph node biopsy (SLNB). Here we describe the camera design and its principal operating characteristics, including spatial resolution, energy resolution, sensitivity uniformity, and geometric linearity. The gamma camera has an intrinsic spatial resolution of 4.2 mm FWHM, an energy resolution of 21.1 % FWHM at 140 keV, and a sensitivity of 481 and 73 cps/MBq when using the single- and double-layer collimators, respectively

    Process description and plant design for preparing ceramic high-level waste forms

    No full text
    The ceramics process flow diagram has been simplified and upgraded to utilize only two major processing steps - fluid-bed calcination and hot isostatic press consolidating. Full-scale fluid-bed calcination has been used at INEL to calcine high-level waste for 18 y; and a second-generation calciner, a fully remotely operated and maintained calciner that meets ALARA guidelines, started calcining high-level waste in 1982. Full-scale hot isostatic consolidation has been used by DOE and commercial enterprises to consolidate radioactive components and to encapsulate spent fuel elements for several years. With further development aimed at process integration and parametric optimization, the operating knowledge of full-scale demonstration of the key process steps should be rapidly adaptable to scale-up of the ceramic process to full plant size. Process flowsheets used to prepare ceramic and glass waste forms from defense and commercial high-level liquid waste are described. Preliminary layouts of process flow diagrams in a high-level processing canyon were prepared and used to estimate the preliminary cost of the plant to fabricate both waste forms. The estimated costs for using both options were compared for total waste management costs of SRP high-level liquid waste. Using our design, for both the ceramic and glass plant, capital and operating costs are essentially the same for both defense and commercial wastes, but total waste management costs are calculated to be significantly less for defense wastes using the ceramic option. It is concluded from this and other studies that the ceramic form may offer important advantages over glass in leach resistance, waste loading, density, and process flexibility. Preliminary economic calculations indicate that ceramics must be considered a leading candidate for the form to immobilize high-level wastes

    Concept of an upright wearable positron emission tomography imager in humans

    No full text
    BACKGROUND: Positron Emission Tomography (PET) is traditionally used to image patients in restrictive positions, with few devices allowing for upright, brain‐dedicated imaging. Our team has explored the concept of wearable PET imagers which could provide functional brain imaging of freely moving subjects. To test feasibility and determine future considerations for development, we built a rudimentary proof‐of‐concept prototype (Helmet_PET) and conducted tests in phantoms and four human volunteers. METHODS: Twelve Silicon Photomultiplier‐based detectors were assembled in a ring with exterior weight support and an interior mechanism that could be adjustably fitted to the head. We conducted brain phantom tests as well as scanned four patients scheduled for diagnostic F(18‐) FDG PET/CT imaging. For human subjects the imager was angled such that field of view included basal ganglia and visual cortex to test for typical resting‐state pattern. Imaging in two subjects was performed ~4 hr after PET/CT imaging to simulate lower injected F(18‐) FDG dose by taking advantage of the natural radioactive decay of the tracer (F(18) half‐life of 110 min), with an estimated imaging dosage of 25% of the standard. RESULTS: We found that imaging with a simple lightweight ring of detectors was feasible using a fraction of the standard radioligand dose. Activity levels in the human participants were quantitatively similar to standard PET in a set of anatomical ROIs. Typical resting‐state brain pattern activation was demonstrated even in a 1 min scan of active head rotation. CONCLUSION: To our knowledge, this is the first demonstration of imaging a human subject with a novel wearable PET imager that moves with robust head movements. We discuss potential research and clinical applications that will drive the design of a fully functional device. Designs will need to consider trade‐offs between a low weight device with high mobility and a heavier device with greater sensitivity and larger field of view
    corecore