302 research outputs found

    Bacillus subtilis vegetative isolate surviving chlorine dioxide exposure: an elusive mechanism of resistance

    Get PDF
    Aims Oxidizing agents such as chlorine dioxide are widely used microbicides, including for disinfection of medical equipment. We isolated a Bacillus subtilis isolate from a washer-disinfector whose vegetative form demonstrated unique resistance to chlorine dioxide (0·03%) and hydrogen peroxide (7·5%). The aim of this study was to understand the mechanisms of resistance expressed by this isolate. Methods and Results A range of resistance mechanisms were investigated in the B. subtilis isolate and a reference B. subtilis strain (ATCC 6051) to include bacterial cell aggregation, the presence of profuse exopolysaccharide (EPS), and the expression of detoxification enzymes. The basis of resistance of the isolate to high concentrations of oxidizing agents was not linked to the presence of endospores. Although, the presence of EPS, aggregation and expression of detoxification enzymes may play a role in bacterial survival to low concentrations of chlorine dioxide, it is unlikely that the mechanisms helped tested to survive the bactericidal effect of higher oxidizer concentrations. Conclusions Overall, the mechanisms conferring resistance to chlorine dioxide and hydrogen peroxide remains elusive. Based on recent advances in the mode of action of oxidizing agents and notably hydrogen peroxide, we postulate that additional efficient intracellular mechanisms may be involved to explain significant resistance to in-use concentrations of commonly used high-level disinfectants

    Comment on the Proposed Definition of “Eligible Organization” for Purposes of Coverage of Certain Preventative Services Under the Affordable Care Act

    Full text link
    In late August 2014, after suffering a defeat in the Supreme Court Hobby Lobby decision when the Court held that business corporations are “persons” that can “exercise religion,” the Department of Health and Human Services (“HHS”) proposed new rules defining “eligible organizations.” Purportedly designed to accommodate the Hobby Lobby ruling, the proposed rules do not comport with the reasoning of that important decision and they unjustifiably seek to permit only a small group of business corporations to be exempt from providing contraceptive coverage on religious grounds. This comment letter to the HHS about its proposed rules makes several theoretical and practical points about the Hobby Lobby holding and how the proposed rules fail to reflect the Court’s reasoning. The letter also addresses other approaches to avoid in the rulemaking process and argues for rules that, unlike what the HHS has proposed, align with the Supreme Court’s reasoning while being consonant with generally applicable precepts of state law and principles of federalism

    Endovascular aneurysm repair increases aortic arterial stiffness when compared to open repair of abdominal aortic aneurysms

    Get PDF
    Objectives: The initial survival advantage seen with endovascular aneurysm repair (EVAR) over open repair does not persist in the long term. Pulse wave velocity (PWV) is a measure of arterial stiffness, and increased PWV is an independent risk factor for increased cardiovascular morbidity and mortality. This prospective comparative pilot study examined the effect of implantation of an aortic graft on PWV in patients undergoing open or endovascular aortic aneurysm repair. Patients and Methods: Thirty-four patients (15 open and 19 EVAR) were recruited. Patient demographics were similar in both the groups. Pulse wave velocity was calculated for all patients preoperatively and postoperatively using a standardized technique on a Philips IU22 Vascular Ultrasound machine and the results compared. Results: An increase in mean PWV following EVAR was demonstrated. The mean post-procedure PWV of 9.7 (+ 4.5) cm/sec detected in the open group was significantly lower than the elevated 12.2 (+ 4.5) cm/ sec detected in the EVAR group. The surgical group also demonstrated a mean decrease of 0.2 (+ 4.9) cm/sec in PWV following open repair compared to a mean increase of 3.3 (+ 3.7) cm/sec in the EVAR group. Conclusion: EVAR patients have a significantly higher postoperative PWV measurement than those undergoing open abdominal aortic aneurysm repair. Patients who have undergone EVAR may be at a higher risk of cardiovascular morbidity in the long term. A larger scale study with a longer prospective follow-up is required

    Screening for peripheral arterial disease and carotid artery disease in patients with abdominal aortic aneurysm

    Get PDF
    Screening for concomitant atherosclerotic disease is important in cardiovascular risk reduction. This study assessed the prevalence of carotid artery disease (CAD) and peripheral arterial disease (PAD) in patients with known abdominal aortic aneurysms (AAAs). All patients with AAA attending the vascular laboratory between the January 1, 2007, and December 31, 2009, were eligible for a carotid ultrasound and measurement of ankle brachial indices. A total of 389 (305 males) patients were identified on the AAA surveillance program with a mean (±standard deviation) age of 76 (±8) years. The mean age of the males was 75.4 (±7.8) years, and the mean age of the females was 77 (±11) years. A total of 332 patients were assessed for CAD, and 101 (30.4%) of those were found to have significant disease. A total of 289 patients were assessed for PAD of which 131 (45.3%) were found to have PAD at rest, and 289 patients were assessed for both and 59 (20.4%) patients had significant CAD + PAD. Patients with AAAs are at high risk of other atherosclerotic disorders, and, therefore, they should receive intensive medical optimization

    Effectively Measuring Exercise-Related Variations in T1ρ and T2 Relaxation Times of Healthy Articular Cartilage.

    Get PDF
    BACKGROUND: Determining the compositional response of articular cartilage to dynamic joint-loading using MRI may be a more sensitive assessment of cartilage status than conventional static imaging. However, distinguishing the effects of joint-loading vs. inherent measurement variability remains difficult, as the repeatability of these quantitative methods is often not assessed or reported. PURPOSE: To assess exercise-induced changes in femoral, tibial, and patellar articular cartilage composition and compare these against measurement repeatability. STUDY TYPE: Prospective observational study. POPULATION: Phantom and 19 healthy participants. FIELD STRENGTH/SEQUENCE: 3T; 3D fat-saturated spoiled gradient recalled-echo; T1ρ - and T2 -prepared pseudosteady-state 3D fast spin echo. ASSESSMENT: The intrasessional repeatability of T1ρ and T2 relaxation mapping, with and without knee repositioning between two successive measurements, was determined in 10 knees. T1ρ and T2 relaxation mapping of nine knees was performed before and at multiple timepoints after a 5-minute repeated, joint-loading stepping activity. 3D surface models were created from patellar, femoral, and tibial articular cartilage. STATISTICAL TESTS: Repeatability was assessed using root-mean-squared-CV (RMS-CV). Using Bland-Altman analysis, thresholds defined as the smallest detectable difference (SDD) were determined from the repeatability data with knee repositioning. RESULTS: Without knee repositioning, both surface-averaged T1ρ and T2 were very repeatable on all cartilage surfaces, with RMS-CV SDD) average exercise-induced in T1ρ and T2 of femoral (-8.0% and -5.3%), lateral tibial (-6.9% and -5.9%), medial tibial (+5.8% and +2.9%), and patellar (-7.9% and +2.8%) cartilage were observed. DATA CONCLUSION: Joint-loading with a stepping activity resulted in T1ρ and T2 changes above background measurement error. EVIDENCE LEVEL: 2 TECHNICAL EFFICACY STAGE: 1 J. MAGN. RESON. IMAGING 2020;52:1753-1764.GlaxoSmithKline National Institute of Health Research (NIHR) Cambridge Biomedical Research Centr

    Mechanism of sporicidal activity for the synergistic combination of peracetic acid and hydrogen peroxide

    Get PDF
    There is still great interest in controlling bacterial endospores. The use of chemical disinfectants and, notably, oxidizing agents to sterilize medical devices is increasing. With this in mind, hydrogen peroxide (H2O2) and peracetic acid (PAA) have been used in combination, but until now there has been no explanation for the observed increase in sporicidal activity. This study provides information on the mechanism of synergistic interaction of PAA and H2O2 against bacterial spores. We performed investigations of the efficacies of different combinations, including pretreatments with the two oxidizers, against wild-type spores and a range of spore mutants deficient in the spore coat or small acid-soluble spore proteins. The concentrations of the two biocides were also measured in the reaction vessels, enabling the assessment of any shift from H2O2 to PAA formation. This study confirmed the synergistic activity of the combination of H2O2 and PAA. However, we observed that the sporicidal activity of the combination is largely due to PAA and not H2O2. Furthermore, we observed that the synergistic combination was based on H2O2 compromising the spore coat, which was the main spore resistance factor, likely allowing better penetration of PAA and resulting in the increased sporicidal activity

    Probing interface defects in top-gated MoS2 transistors with impedance spectroscopy

    Get PDF
    The electronic properties of the HfO2/MoS2 interface were investigated using multifrequency capacitance–voltage (C–V) and current–voltage characterization of top-gated MoS2 metal–oxide–semiconductor field effect transistors (MOSFETs). The analysis was performed on few layer (5–10) MoS2 MOSFETs fabricated using photolithographic patterning with 13 and 8 nm HfO2 gate oxide layers formed by atomic layer deposition after in-situ UV-O3 surface functionalization. The impedance response of the HfO2/MoS2 gate stack indicates the existence of specific defects at the interface, which exhibited either a frequency-dependent distortion similar to conventional Si MOSFETs with unpassivated silicon dangling bonds or a frequency dispersion over the entire voltage range corresponding to depletion of the HfO2/MoS2 surface, consistent with interface traps distributed over a range of energy levels. The interface defects density (Dit) was extracted from the C–V responses by the high–low frequency and the multiple-frequency extraction methods, where a Dit peak value of 1.2 × 1013 cm–2 eV–1 was extracted for a device (7-layer MoS2 and 13 nm HfO2) exhibiting a behavior approximating to a single trap response. The MoS2 MOSFET with 4-layer MoS2 and 8 nm HfO2 gave Dit values ranging from 2 × 1011 to 2 × 1013 cm–2 eV–1 across the energy range corresponding to depletion near the HfO2/MoS2 interface. The gate current was below 10–7 A/cm2 across the full bias sweep for both samples indicating continuous HfO2 films resulting from the combined UV ozone and HfO2 deposition process. The results demonstrated that impedance spectroscopy applied to relatively simple top-gated transistor test structures provides an approach to investigate electrically active defects at the HfO2/MoS2 interface and should be applicable to alternative TMD materials, surface treatments, and gate oxides as an interface defect metrology tool in the development of TMD-based MOSFETs

    Uniform wafer-scale synthesis of graphene on evaporated Cu (111) film with quality comparable to exfoliated monolayer

    Full text link
    Monolayer graphene has been grown on crystallized Cu (111) films on standard oxidized Si 100 mm wafers. The monolayer graphene demonstrates high uniformity (>97% coverage), with immeasurable defects (>95% defect-negligible) across the entire wafer. Key to these results is the phase transition of evaporated copper films from amorphous to crystalline at the growth temperature as corroborated by X-ray diffraction and electron backscatter diffraction. Noticeably, phase transition of copper film is observed on technologically ubiquitous oxidized Si wafer where the oxide is a standard amorphous thermal oxide. Ion mass spectroscopy indicates that the copper films can be purposely hydrogen-enriched during a hydrogen anneal which subsequently affords graphene growth with a sole carbonaceous precursor for low defect densities. Owing to the strong hexagonal lattice match, the graphene domains align to the Cu (111) domains, suggesting a pathway for increasing the graphene grains by maximizing the copper grain sizes. Fabricated graphene transistors on a flexible polyimide film yield a peak carrier mobility ~4,930 cm2/Vs
    • 

    corecore